4

5

PC

RJ45

HUB

EtherNet Tower

VDC 12/24

EtherNet Network

DC

Power

Fuse

White

Black

LAN CABLE

• Connect RJ45 connector that is connected to UTP cable to 

  Ethernet port of a PC or a router.

• External power line - UL1015 AWG18(0.75sq) x 2C 400mm 

• For AC type, power cable is equipped with the product.

• UTP Cable: Category 5 cable

Wiring Instructions

5. When you unzip “ETN TEST PROGRAM.zip” file, following folders are created.

4. When you unzip the file, there will be a file with the same name below. The instructions are listed inside the file.

Program Sample needed when developing

(x32bit/x64bit compatibility)

Instructions of how to use the product and library file

A program for setting IP before testing the ETN device

A program for setting testing the ETN device

■ Test Ethernet LED Tower Light

1. Please connect LAN cable of the tower light to the router so that 

    the tower light can access Ethernet network by referring left 

    diagram.

2. Please be sure that the power supply shall meet the product 

    specification accordingly.

Product Installation

2. Because the ETN tower light is connected to a hub with the PC that is same as the picture on the front page, ETN tower 
    light and the PC are now connected with the same network.

3. Please download the product manual, library file and test program from Qlight website(www.qlight.com) or blog.qlight.com

1. Please activate default PC network only. Please run Windows CMD(Command line) of PC over the same network in order to confirm

    network information where the Ethernet product will be connected.

    Example) Windows 7 : Start(Run)->CMD->ipconfig /all
                    Windows 10 : Start menu-> Click right mouse button->CMD->ipconfig /all
   - Please refer to below network information when the Ethernet product’s network environment is configured.

Applying the Ethernet Device

Ethernet adapter 

Local Area Connection

:

Connection-specific DNS Suffix  . :
IP Address. . . . . . . . . . . . : 192.168.10.101
Subnet Mask . . . . . . . . . . . : 255.255.255.0
Default Gateway . . . . . . . . . : 192.168.10.1

VAC 110V~220V

Installation wiring instructions

Содержание QTR50L

Страница 1: ...oduct in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection ratings indicated for each product Failure to follow these instructions may cau...

Страница 2: ...ax 0 110A R Red A Amber G Green 4 DC12V DC24V AC110V 220V 0 450A 0 290A Max 0 130A R Red A Amber G Green B Blue 5 DC12V DC24V AC110V 220V 0 525A 0 335A Max 0 150A R Red A Amber G Green B Blue W White...

Страница 3: ...AD 13 5 40 13 5 40 POWER CABLE RJ45 LAN CONNECTOR POWER CABLE 360 3 M4 BOLT RJ45 LAN CONNECTOR 20026 5 L1 135 M18x1 5 THREAD 12 12 5 123 L2 BUZZER VOLUME CONTROL LEVER 13 5 50 13 5 50 360 3 M4 BOLT RJ...

Страница 4: ...net network by referring left diagram 2 Please be sure that the power supply shall meet the product specification accordingly Product Installation 2 Because the ETN tower light is connected to a hub w...

Страница 5: ...alue of users network information identified in the previous chapter subnet mask gateway in each text box and set a different IP_Addr than your PC Apply the settings by pressing the Write button The p...

Страница 6: ...by removing the upper lens kit from the lower one Assembling lens kits Put the two lens kits together by aligning the upper lens I mark and the lower lens I mark together Lock the two kits by twisting...

Страница 7: ...HOLES 360 6 5 HOLES 12 Mounting Hole Specifications Machine holes on the mounting surface referring to the diagram below Remove the flange nuts from bolts and place the product through the mounting su...

Страница 8: ...ETN Pole Mounting Type Model 18 18 32 34 24 70 51 M18x1 5 THREAD 75 52 69 18 18 66 52 38 34 46 50 58 28 1 2 PF 4 5 HOLES 12x22 CABLE ENTRY 70 50 18 4 5 HOLES PCD 56 4 5 5 HOLES 2 8 5 HOLES PCD 54 56...

Страница 9: ...ting Type Model 46 70 81 32 34 46 M24x1 5 THREAD 2 8 5 HOLES 69 5 52 38 34 46 50 70 1 2 PF 4 5 HOLES 12x22 CABLE ENTRY 33 24 70 55 4 5 5 HOLES PCD 54 56 24 4 5 HOLES 90 55 5 PCD 73 24 35 24 24 90 4 6...

Страница 10: ...ing the sky Sounder part shall not be facing the sky BEACON SIGNALING LIGHT Power cord inlet part shall not be facing the sky Power cord inlet part shall not be facing the sky SIGNAL TOWER LIGHTS HEAV...

Страница 11: ...MEMO...

Страница 12: ...2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 8384 9910 Product Operation Inquiry Customer Support 82 51 620 4100 Y...

Отзывы: