the number of IO channels extended for QD1 exceeds 64, repeat Step 2~Step
3 to configure Data ID 583 in Node2 Modbus TCP (e.g. 6 daughterboards are
installed with a maximum of 112 IO channels, and "192.168.2.247, 1:B, 64,
10201, 1:B, 64, 201" is entered in Date ID 583 of Node2 Modbus TCP).
Table 4-1 Parametric rules of Web Server IP
①
② ③ ④ ⑤ ⑥ ⑦
○
1
IP address configured for QD1 motherboard
○
2
The first input channel at the beginning of Input, with an initial value of 1
○
3
The last input channel at the end of Input, with a maximum value of 64
○
4
The first input channel mapped to controller, with an initial value of I
10101
○
5
The first input channel at the beginning of Output, with an initial value of
1
○
6
The last input channel at the end of Output, with a maximum value of 64
○
7
The first output channel mapped to controller, with an initial value of O
101
Step 4
Click <Set new values> to save the settings.
Step 5
Change the value of Data ID 582 in Figure 4-8 to 1. ("1" means effective,
"0" means ineffective).
Step 6
Click <Set new values> again to save the settings.
Step 7
Finally, click <Save All to Flash> to save the values permanently.
4.2.3 Web Interface IO control
After configuring connection to Web Server, open <Control Panel>, <Remote I/O>
and <RIO 1> in sequence, and the IO control of QD1 is displayed on the IO control panel
of Web Interface.