![Qimarox PRORUNNER mk9 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/qimarox/prorunner-mk9/prorunner-mk9_user-manual_765757057.webp)
UM-PRORUNNER_mk9-2.0-EN
57
Pneumatic circuit diagrams
10
Pneumatic circuit diagrams
10.1
Mechanical locking device
When power and compressed air is applied to the mechanical locking device, compressed
air goes to the cylinders and the locking pin retracts. This will be applied until the
emergency stop circuit is triggered or a power failure occurs. When this happens air will
rapidly flow out of the cylinders and the locking pin will hook into the column, hence
holding the carrier into its position.
2
12
MS6-SV-1/2-E-10v24-SO-AG
ESNU-25-25-PA
ESNU-25-25-PA
1
3