background image

 

 
 

QIAreach eHub User Manual   10/2020 

14 

 

Battery LED indicator 

Figures 1 and 2 show the location of various QIAreach eHub features. 

 

Figure 1. Front view of QIAreach eHub. 

 

Figure 2. Side view of QIAreach eHub. 

 

 

 

 

Содержание QIAreach eHub

Страница 1: ...Sample to Insight__ October 2020 QIAreachTM eHub User Manual 9002969 QIAGEN GmbH QIAGEN Strasse 1 D 40724 Hilden R2 1118891EN...

Страница 2: ...QIAreach eHub User Manual 10 2020 2...

Страница 3: ...1 System description 13 3 2 QIAreach eHub description 13 4 Installation Procedures 15 4 1 Site requirements 15 4 2 QIAreach eHub delivery and components 16 4 3 Unpacking and installing the QIAreach eH...

Страница 4: ...26 8 3 QIAreach eHub error codes 26 9 Technical Specifications 32 10 Appendix A Technical Data 34 10 1 FCC Compliance Supplier s Declaration of Conformity 34 10 2 Waste Electrical and Electronic Equip...

Страница 5: ...owed to ensure safe operation of the instrument and to maintain the instrument in a safe condition 1 1 About this user manual This user manual provides information about QIAreach eHub in the following...

Страница 6: ...hen contacting QIAGEN Technical Services about errors please have the following information ready QIAreach eHub serial number Test type and test kit lot number Error code if applicable Timestamp when...

Страница 7: ...USB cable supplied with this product When charging the QIAreach eHub use only the USB charger and USB cable supplied with this product The QIAreach eHub should only be operated on a flat horizontal su...

Страница 8: ...er box label of the eHub Catalog Number Type plate and outer box label of the eHub Serial Number Type plate and outer box label of the eHub Global Trade Item Number Outer box label of the eHub Fragile...

Страница 9: ...reach eHub User Manual 10 2020 9 Type plate and outer box label of the eHub UL mark that indicates the instrument complies with the applicable standards for electrical safety Front of the eHub Biohaza...

Страница 10: ...owing types of safety information appear throughout the QIAreach eHub User Manual WARNING The term WARNING is used to inform you about situations that could result in personal injury to you or others...

Страница 11: ...ety Observe all general safety precautions that apply to electrical instruments This device has been tested for compliance with electrical safety requirements as per IEC 61010 1 Safety requirements fo...

Страница 12: ...resented by such agents and should use store and dispose of such samples according to the required safety regulations Wear personal protective equipment when handling reagents or samples and wash hand...

Страница 13: ...ously The eHub is connected to a power source using the provided connection cable and features a rechargeable lithium battery to allow QIAreach tests to be performed when a continuous power supply is...

Страница 14: ...QIAreach eHub User Manual 10 2020 14 Battery LED indicator Figures 1 and 2 show the location of various QIAreach eHub features Figure 1 Front view of QIAreach eHub Figure 2 Side view of QIAreach eHub...

Страница 15: ...correct operating conditions temperature and humidity There should be sufficient clearance on the workbench to allow unimpeded access to the eStick connection ports USB port and ON OFF button Note Bef...

Страница 16: ...ponents for setting up and connecting the eHub The contents of the box are described below Note QIAreach tests kits sold separately are required to perform QIAreach testing Components Description 1x Q...

Страница 17: ...ollowing components are required for testing but are provided in separate test kits These components can be purchased separately Components Description QIAreach eStick product specific Processing Tube...

Страница 18: ...e charging the Battery LED indicator flashes a green light When fully charged then light changes to a solid green if the unit is on Figure 3 Connecting the USB cable to the QIAreach eHub USB port Note...

Страница 19: ...when not in use We also recommend that you connect the eHub to a USB power source either a USB adapter or computer during operation If testing is performed without the use of associated QIAreach soft...

Страница 20: ...IAreach eHub is ready for use the visual display screen above each available QIAreach eStick connection port will display the Insert eStick icon shown below Figure 6 Insert eStick icon This signifies...

Страница 21: ...lf test icon will be displayed while the eStick performs a self test Figure 7 Self test screen display 2 Once the eStick self test has successfully completed the Add sample icon will be displayed sign...

Страница 22: ...y pressing and holding the ON OFF button for 2 5 seconds The QIAreach eHub battery will continue to charge when turned off if connected to a power source After each use clean the eHub according to the...

Страница 23: ...dded within 60 minutes of removing the eStick from the foil packaging Processing The eStick has detected sample and is processing the test A test countdown timer is displayed Do not remove the eStick...

Страница 24: ...the QIAreach eHub to a computer through the provided USB cable and launching the QIAreach software The software displays the level of battery charge in the bottom right hand corner of the screen The...

Страница 25: ...into the eStick connection ports C4 CAUTION Risk of damage to the QIAreach eHub Avoid the use of excessive volumes of liquid that could enter the interior of the unit when cleaning the QIAreach eHub...

Страница 26: ...l Services about an error with the QIAreach eHub note the steps leading up to the error This information will help QIAGEN Technical Services solve the problem When contacting QIAGEN Technical Services...

Страница 27: ...ck A 16 Voltage Failure Remove and re insert the eStick If error persists discard and use new eStick A 32 Voltage Failure Remove and re insert the eStick If error persists discard and use new eStick A...

Страница 28: ...use new eStick A 8192 LED Current Failure Remove and re insert the eStick If error persists discard and use new eStick A 16384 LED Current Failure Remove and re insert the eStick If error persists di...

Страница 29: ...requency Out of Range Discard and use new eStick B 16 Low Frequency Ensure sample is mixed in processing tube prior to adding test sample Discard and use new eStick B 17 High Frequency Discard and use...

Страница 30: ...tinue use of eHub port C 5 Metadata Failure Remove and re insert the eStick If error persists discard and use new eStick If error persists with new eStick discontinue use of eHub port C 6 Measurement...

Страница 31: ...eStick C 12 Test Removed Too Early Wait for test completion before removing eStick Discard and use new eStick C 13 Connection Error Remove and re insert the eStick If error persists discard and use n...

Страница 32: ...tery non user seviceable Voltage 3 7V nominal Capacity 3350 mAh nominal Operating conditions Air Temperature 15 30 C 59 86 F Relative Humidity 30 65 non condensing Place of Operation For Indoor use on...

Страница 33: ...neral requirements Meets the requirements of CISPR 11 2015 ISM Equipment Radiated RF Emissions as a Group 1 Class A device Meets the requirements of FCC Title 47 CFR Part 15 Subpart B unintentional ra...

Страница 34: ...reasonable protection against harmful interference when the equipment is operated in a commercial environment This product generates uses and can radiate radio frequency energy and if not installed an...

Страница 35: ...ff and on you are encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the antenna of the radio television receiver Increase the separation betwe...

Страница 36: ...cost In the European Union in accordance with the specific WEEE recycling requirements and where a replacement product is being supplied by QIAGEN free recycling of its WEEE marked electronic equipme...

Страница 37: ...ach software 1 USB charging cable 1 power adapter 1 QIAreach eHub dust cover 9002969 For up to date licensing information and product specific disclaimers see the respective QIAGEN kit handbook or use...

Страница 38: ...the cover page Updated the Symbols section to add the RoHS UL and Biohazard symbols Added the Biohazard warning in the Biological Safety section Updated the Unpacking and installing the QIAreach eHub...

Страница 39: ...rties 2 Other than expressly stated licenses QIAGEN makes no warranty that this kit and or its use s do not infringe the rights of third parties 3 This kit and its components are licensed for one time...

Страница 40: ...QIAreach eHub User Manual 10 2020 40 Ordering www qiagen com shop Technical Support support qiagen com Website www qiagen com...

Отзывы: