background image

7

Page

Well Wizard®

   

Installation and Operation Manual

    

Rev. A  2-1-2018

Well Cap (Figure 4)

Figure 4

Содержание Well Wizard 1100 Series

Страница 1: ...Well Wizard Installation and Operation Manual Rev A 2 1 2018 Dedicated Monitoring Systems QEDENV COM INSTALLATION GUIDEE P N 34999...

Страница 2: ...7 Portable Components 8 Installing the Components 9 Installing the Inlet Screen 10 Installing the Sample Pump 11 Installing the Sample Pump With Bulk Tubing 12 13 Bladder Pump Operation In Low Submer...

Страница 3: ...6 8045 if you are outside the U S Introduction To monitor the quality of ground water you need an efficient way to collect unbiased samples Well Wizard is a total system for meeting all your ground wa...

Страница 4: ...2 Page Well Wizard Installation and Operation Manual Rev A 2 1 2018 Sampling Pump A Well Wizard sampling pump is an air actuated bladder pump that you permanently position in the well...

Страница 5: ...Upper end check valve assembly polyvinyl chloride PVC or Teflon Lower end check valve assembly PVC or Teflon Bladder Cartridge Teflon Pump Body PVC or Teflon You can totally disassemble the pump witho...

Страница 6: ...adder squeezes the water inside the bladder into the exit entrance holes of the fill rod As air pressure increases liquid having no place else to go is forced up the discharge line and to the surface...

Страница 7: ...op check ball is forced down and seals because of the force of the water pressure above it from the water in the discharge tubing this prevents the water in the discharge tube from reentering the blad...

Страница 8: ...h for your well Inlet Screen An inlet screen can protect the bladder in your Well Wizard pump by preventing sand from contacting the bladder If you install a screen on your dedicated Well Wizard bladd...

Страница 9: ...7 Page Well Wizard Installation and Operation Manual Rev A 2 1 2018 Well Cap Figure 4 Figure 4...

Страница 10: ...wdown water level meter can be connected to the QED cycle controllers to automatically control the drawdown during purging and sampling The series 6000 electronic water level meters use a portable con...

Страница 11: ...your order confirmation and packing list Make certain every component you ordered is there and familiarize yourself with how components go together before you go to the field 3 Carry the box to the we...

Страница 12: ...2 Thread the screen onto the male threaded pump inlet making sure the screen is firmly tight Screens For 1200 and 1300 Series Pumps To install a screen on an 1200 1300 series pump follow these steps...

Страница 13: ...n such as well ID and depth on the label inside the well cap 2 Slowly lower the pump into the well while uncoiling the tubing bundle until the entire length of tubing is in the well Be sure to control...

Страница 14: ...The correct screen for each pump is usually included with the other components for the well the box label tells you where to find the screen The following sections describe how to install the two type...

Страница 15: ...he discharge tube fitting Note This is usually 3 to 4 inches You determine the exact length by checking both fitting nuts for full tube insertion after loose assembly 6 Make sure that the tube to pump...

Страница 16: ...erge the pump s discharge tubing in a beaker of water Each time the pump goes into discharge air in the discharge tubing which is displaced as the water level in the tubing rises can be seen as air bu...

Страница 17: ...an get into the fitting and later cause a leak To install a stainless steel connector follow these steps 1 If you are working with a 1 2 or 3 4 inch connector wrap the male threads under the nut with...

Страница 18: ...ing on the size of the tube fitting For fittings larger than 3 16 inch turn the fitting one and one quarter turns watch the scribe mark make one complete turn then continue to the 3 o clock position F...

Страница 19: ...y to length 2 If the tubing is larger than 1 2 inch push an insert into the tube 3 Push the tubing into the completely assembled connector until it contacts the shoulder inside the fitting see figure...

Страница 20: ...18 Page Well Wizard Installation and Operation Manual Rev A 2 1 2018 Figure A 1 shows the Type A sampling system the basic bladder pump Sampling System Type A...

Страница 21: ...19 Page Well Wizard Installation and Operation Manual Rev A 2 1 2018 Figure A 2 shows the Type L sampling system a bladder pump with an inlet extension Sampling System Type L...

Страница 22: ...20 Page Well Wizard Installation and Operation Manual Rev A 2 1 2018 Sampling Pump Troubleshooting Guide...

Страница 23: ...remedy for breach of said warranty shall be as follows if and only if Q E D is notified in writing within applicable warranty period of the existence of any such defect in the said products and Q E D...

Страница 24: ...repaired or modified by persons other than Q E D s service personnel unless such repair by others is made with the written consent of Q E D If any product covered hereby is actually defective within t...

Отзывы: