QED Environmental Systems
Skimmer Manual
Page 24
A ter the entire site is operating, return to each well to ensure that the pump is
functioning properly.
Special Operating Conditions
Conditions may require adjustment or adaptations to the equipment. Below is a list
of some of these conditions, their possible effects and possible solutions. (And as
always, please contact
QED
for detailed assistance if needed.)
1.
If a high water level condition persists for several days, indicating a change in the
local water table, you may need to raise the skimmer so that product removal can
again take place.
2.
If the recovery well experiences a sudden influx of water, due to rain or snow melt
for example, the skimmer head may be submerged in water rather than product,
due to its limited travel.
3.
If the skimmer is an SOS type, and it has been submerged, check the recovery tank
to confirm there is no water.
Содержание SOS
Страница 3: ......
Страница 29: ...QED Environmental Systems Skimmer Manual Page 22 Figure 12 Four Inch Selective Oil Skimmer SOS Down Well...
Страница 45: ...QED Environmental Systems Page 38 Skimmer Manual Figure 15 2 inch Specific Gravity Skimmers SPG 2...
Страница 52: ...Page 45 Skimmer Manual Revision 1 December 2007 Log Notes...
Страница 53: ...QED Environmental Systems Skimmer Manual Page 46...
Страница 54: ...Page 47 Skimmer Manual Revision 1 December 2007 Log Notes...
Страница 55: ...QED Environmental Systems Skimmer Manual Page 48...