HSC505 - E 8-32 Zone LCD Home Security Controller - Installation Manual
________________________________________________________________________________
Page 18
This document and product are copyrighted and all rights are reserved.
QUESTION 1 to 34
Location 1 = Zone type,
Location 2 = Partition number,
Location 3 = Reporting code 1,
Location 4 = Reporting code 2.
Location 1:
Zone type
0
Disabled
1
Entry/exit
2
Follower
3
Instant audible
4
Instant silent
5
Keypad buzzer
A
24-hour audible
B
24-hour silent
C
Fire
D
24-hour keypad buzzer
E
Keyswitch
Location 2:
Partition assignment
Assign zone to a partition 1 through 4. If a zone is programmed as a 5, the zone then becomes common to
all partitions. This means that the zone will only arm when the last partition arms and will disarm with any
partition disarming. Any not ready common zones will only be indicated on the last to arm partition.
1
Partition 1
2
Partition 2
3
Partition 3
4
Partition 4
5
Common to all partitions
Location 3:
Reporting code digit 1
Reporting code to identify the alarm condition when using either standard or express formats. This would
also be the Point ID code.
To disable the reporting code, enter a value of “A” into the location.
Location 4:
Reporting code digit 2
Reporting code to identify the zone number when using standard or express formats. lor contact ID this
location becomes a 0.
Zones:
1 to 8
2k7 EOL resistor programmable zones on the control panel.
9 to 16
2k7 EOL resistor programmable zones on the onboard expander.
17 to 24
Keypad or expander zones. Each keypad installed provides 1 additional 2k7 input zone and
1 trigger output.
NOTE: - keypad zones are enabled in question 60 - L3 & L4.
25 to 32
2k7 EOL zones on an 8-zone bus expander (future expansion).
33
Panic input2k7 ohm EOL resistor . Programmable only as 24-hour audible;
24-hour silent or keyswitch.
34
Tamper input . Programmable only as 24-hour audible;
24-hour silent or keyswitch.