background image

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK_DUO-G10.X

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK_DUO-G10.X

10

11

3 Installation

3.1 Safety and transport

  Leave modules in their original packaging until 

installation.

  Store the modules securely in cool and dry rooms. 

The packaging is not weatherproof.

  Inspect the packaging for damages.

  Contact the transport company regarding any 

damage to the packaging and follow their 

instructions.

  Follow any instructions on the packaging.

  Ensure that all personnel are aware of and adhere to 

accident-prevention and safety regulations.

  While working wear clean gloves.

§

GB

§

I

§

D

Danger! Risk of fatal injury due to electric shock!

  Do not install damaged modules.

  Inform your distributor of any damages immediately.

Warning! Fire Risk!

  Do not install modules indoors.

  Do not install modules on moving objects.

2 Planning

2.4 Electrical layout

Module Selection

For detailed key electrical data, please refer to the actual data 

sheet referring to the relevant Module (available at www.qcells.

com/).

  For maximum energy yields, mismatches of specified electric 

current (I

MPP

) of more than 5 % should be avoided for all 

modules connected in series.

Safety Factor

For detailed key electrical data, please refer to the actual data 

sheet referring to the relevant Module (available at www.qcells.

com).

 

During normal operation, a module may generate a greater 

current and / or higher voltage than that determined under 

standardized test conditions. Please use a safety factor of 1.25 

for the following:

 

Calculating the voltage measurement values (V

OC

) of 

components

 

Calculating the current measurement values (I

SC

) of conductors

 

Sizing of control systems connected to the outlets of the solar 

modules

  Please follow the valid national guidelines for the installation of 

electrical systems.

Series Connection

Connection of modules in series is only permitted up to the 

maximum system voltage as listed in the applicable data sheet of 

all the relevant modules to be installed.

  Take into account all possible operating situations and all 

relevant technical norms and regulations when designing the 

system. It has to be ensured that the maximum system voltage, 

including all necessary safety margins, is not exceeded.

  Take the voltage limit of the inverter into account when 

determining the maximum number of modules in the string.

Parallel Connection

Modules may be damaged by the occurrence of reverse currents 

(caused by module defects, ground leaks, or defective insulation).

  Ensure that the maximum reverse current load capacity 

indicated in the data sheet is met.

In order to limit reverse currents that may occur, we recommend 

using the following safety options:

1) Layout with a limited number of parallel connected strings :

Without undertaking further current blocking measures, a 

maximum of two module strings may be operated in parallel on a 

single inverter or MPP tracker.

2) Layout with string fuses :

Use overcurrent devices (e.g. fuses) according to the relevant 

standards in each string. Use gPV-fuses according to IEC 

60269-6. Observe the maximum permitted number of strings as 

indicated in the specifications provided by the respective string 

fuse manufacturer and the technical guidelines.

NOTE!

When installing different product versions, the lowest minimum 

permitted reverse current load capacity applies.

Inverters

Inverters with or without transformers may be used.

Содержание Q.PEAK DUO-G10.X Series

Страница 1: ...Installation and operation manual Q PEAK DUO G10 X solar module series...

Страница 2: ...the solar modules This manual Other applicable stipulations such as country specific regulations for pressure equipment operational safety hazardous goods and environmental protection Regulations and...

Страница 3: ...itional information see the relevant datasheet of the module provided at www qcells com PRODUCT LINE Q PEAK DUO G10 Q PEAK DUO G10 Q PEAK DUO G10 a Q PEAK DUO G10 a Q PEAK DUO BLK G10 Q PEAK DUO BLK G...

Страница 4: ...fastened to the ground the roof or the fa ade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Avoid the usage of different metals...

Страница 5: ...termination of location specific load requirements Ensure that the connection cables of the junction box do not run between laminate and mounting rails Modules bend under load Therefore sharp objects...

Страница 6: ...ulating the current measurement values ISC of conductors Sizing of control systems connected to the outlets of the solar modules Please follow the valid national guidelines for the installation of ele...

Страница 7: ...insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not modify the module e g do not drill any additional holes 3 Installation 3 1 Safety and trans...

Страница 8: ...he inverter and the wiring with extreme caution Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the time intervals specified by the inverter manufacture...

Страница 9: ...e condition To avoid complex cabling arrangements it is often advantageous to rotate some modules 180 Module orientation can clearly be identified from the front side by the serial number and barcode...

Страница 10: ...Please contact an installer or Qcells Technical Customer Service Department Dispose of modules in accordance with the local disposal regulations 4 Electrical connection 4 4 After installation Ensure t...

Страница 11: ...occur Remove snow and ice carefully without force e g with a very soft broom Do not scratch off dirt Module cleaning has to be done by qualified personnel according to the state of the art and taking...

Страница 12: ...stallation manual solar modules Q PEAK_DUO G10 X_2022 06_Rev02_EN Hanwha Q CELLS GmbH OT Thalheim Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany EMAIL WEB TEL FAX sales qcells com www qcells com 49...

Отзывы: