1 Introduction

Validity

These instructions are only valid for crystalline solar modules 
from the company Qcells as specified at chapter "2.1 Technical 
specifications". Qcells assumes no liability for damage resulting 
from failure to observe these instructions.

  Please observe the wiring and dimensioning of the system.
  The installer of the system is responsible for compliance with 

all necessary safety regulations during set-up and installation.

Qcells assumes no liability on the basis of these instructions. 
Qcells is only liable in the context of contractual agreements or 
in the context of accepted guarantees. Qcells accepts no other 
responsibility for the functionality and safety of the modules.

  Please observe the instructions for any other system compo-

nents that may be part of the complete solar power system. It 
may be necessary to carry out a structural analysis for the en-
tire project.

  If your questions are not satisfactorily answered in the manual, 

please contact your system supplier.

Additional information can be found on our website at 
www.qcells.com.

Information for the Operator

  Please keep this manual for the entire life of the solar power 

system.

  Please contact your system supplier for information concerning 

the formal requirements for solar power systems.

  Please be sure to contact the relevant local authorities and en-

ergy providers regarding regulations and permit requirements 
prior to installation of the solar power system. Your financial 
success depends on the fulfillment of these requirements.

Other applicable documents

This installation manual is only valid in combination with the fol-
lowing technical information.

Document type

Product data sheet

Packaging and transport information

 
MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE 
LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD 
AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER IN-
STALLATION OR CONFIGURATION, IMPROPER MAINTENANCE, 
UNINTENDED USE, AND UNAUTHORIZED MODIFICATION.

Attention!

This marking indicates that this product should not be disposed 
of with other household waste within the EU. Recycle this product 
properly to prevent possible damage to the environment or a risk 
to human health via uncontrolled waste disposal and in order to 
promote the sustainable reuse of material resources. Please re-
turn your used product to an appropriate collection point or con-
tact the retailer where you purchased this product. Your retailer 
will accept used products and return them to an environmental-
ly-sound recycling facility.

2 Planning

2.1 Technical specifications

For additional information see the relevant datasheet of the module provided at www.qcells.com.

PRODUCT LINE

Q.PEAK DUO BLK ML-G10/t                             Q.PEAK DUO BLK ML-G10+/t              

Type

Q.ANTUM DUO Z

Length [in]

74.0 (1879 mm)

Width [in]

41.1 (1045 mm)

Frame height [in]

1.26 (32 mm)

Area [yd²]

2.3 (1.96 m²)

Weight [lbs]

48.5 (22.0 kg)

Max. system voltage V

SYS

1000 V

Max. series fuse rating

20 A

Permissible temperature range

–40 °F to +185 °F(–40 °C to +85 °C) 

Junction box protection class

IP67 with bypass diode

Connector protection class

IP68

Fire rating based on ANSI / 
UL 61730

C / Type 2

Max. test load Push / Pull

1

 [lbs/ft²]

113 / 84 (5,400 Pa / 4,000 Pa)

Max. design load  
Push / Pull

1

 [lbs/ft²]

75 / 55.6 (3,600 Pa / 2,660 Pa)

Certificates

Quality Controlled PV by TÜV Rheinland; CE-compliant; IEC 61215:2016; 
IEC 61730:2016; PV module classification: Class II; UL 61730; QCPV

1

 Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section "2.3 Mounting options")

NA

DETAIL A

0.63" (16 mm)

0.33" (8.5 mm)

0.96" (24.5 mm)

42.8" (1088 mm)

74.0" (1879 mm) 

4 × Mounting slots (DETAIL A)

Frame

41.1" (1045 mm)

39.2" (996 mm)

1.26" (32 mm)

8 × Drainage holes

15.6“ (395.5 mm)

4 × Grounding points ø 

0.18" (

4.5 mm)

Label

72.04

" (

1830 mm)

72.04

" (

1830 mm)

Fig. 1: 

External dimensions and components for Q.PEAK DUO BLK ML-G10/t, Q.PEAK DUO BLK ML-G10+/t

Содержание Q.PEAK DUO BLK ML-G10/t Series

Страница 1: ...Installation and operation manual Q PEAK DUO BLK ML G10 t solar module series ...

Страница 2: ...ator are responsible for com pliance with all applicable statutory requirements and regulations The following regulations and standards must be upheld at all times during the installation operation and maintenance of the solar modules Installation and Operation Manual Other applicable documents such as country specific reg ulations for pressure equipment operational safety hazard ous goods and env...

Страница 3: ...OR INCORRECT USE OF SOLAR MODULES VOIDS THE LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD AND RISK PROPERTY DAMAGE THIS INCLUDES IMPROPER IN STALLATION OR CONFIGURATION IMPROPER MAINTENANCE UNINTENDED USE AND UNAUTHORIZED MODIFICATION Attention This marking indicates that this product should not be disposed of with other household waste within the EU Recycle this product properly to prevent poss...

Страница 4: ...Ensure that no additional forces are applied through the mount ing system into the module except for the wind and snow loads Additional forces and moments of torque at the mounting po sitions caused by torsions displacements or vibrations in the mounting system are not allowed Ensure that the clamps and the mounting frame are compatible Clamp System Recommendations Use customary clamps that satisf...

Страница 5: ...m long side 11 8 17 7 300 450mm CL6c outer clamps 0 79 19 7 20 500mm middle clamps 25 2 48 8 640 1240mm 3600 3000 2400 2000 outer clamps 0 79 13 8 20 350mm middle clamps 25 2 48 8 640 1240mm 4000 4000 2660 2660 CL6d short side 0 79 9 84 20 250mm long side 25 2 48 8 640 1240mm 4000 3600 2660 2400 The below mounting options are only possible under certain conditions MOUNTING OPTION POSITION OF CLAMP...

Страница 6: ... load 2 Planning 2 3 Mounting options 2 Planning 2 4 Electrical layout Module Selection For detailed key electrical data please refer to the actual data sheet referring to the relevant Module available at www qcells com For maximum energy yields mismatches of specified electric current IMPP of more than 5 should be avoided for all mod ules connected in series Safety Factor During normal operation ...

Страница 7: ...ock Do not install damaged modules Inform your distributor of any damages immediately Warning Fire Risk Do not install modules indoors Do not install modules on moving objects 3 Installation 3 1 Safety and Transport Note Module damage may occur Do not stack modules Note Module damage may occur Do not install modules near flammable gas vapors Do not install modules in close proximity to air condi t...

Страница 8: ... of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not modify the module e g do not drill any additional holes 3 Installation 3 3 Module installation Option 1 Fasten the module with 4 clamps in the specified clamping range see Fig 2 p 7 Tighten clamps according to manufacturer s instruc tions ...

Страница 9: ...paration Be sure to observe the time intervals specified by the inverter manufacturer after switching off the inverter Make sure that the plugs can not be connected unintentionally Before working on the contacts check them for safety ex tra low voltage Danger Risk of fatal injury due to electric shock Only use dry insulated tools for electrical work Danger Risk of fatal injury due to electric shoc...

Страница 10: ...her audibly Danger Risk of fatal injury due to electric shock Ensure that all electrical components are in a proper dry and safe condition To avoid complex cabling arrangements it is often advantageous to rotate some modules 180 Module orientation can clearly be identified from the front side by the serial number and barcode labelled behind the module glass on the side with negative connection cab...

Страница 11: ...should be attached to the frame grounding hole using a stainless steel screw toothed lock washer or KEPS nut in order to penetrate the anodized layer and backing nut Care should be taken to avoid the use of grounding hardware of dissimilar metals which may lead to corrosion Option B Integrated grounding methods The Qcells modules can be bonded with the racking system us ing UL1703 or UL2703 certif...

Страница 12: ...age may occur Remove snow and ice carefully without force e g with a very soft broom Do not scratch off dirt Module cleaning has to be done by qualified personnel ac cording to the state of the art and taking into account all rele vant safety issues and general product properties e g but not restricted to electrical safety mechanical stability load limits depending on the actual mounting options c...

Страница 13: ...nstallation manual solar modules Q PEAK_DUO_BLK_ML G10 X t_modules_series_2023 02_Rev02_NA HANWHA Q CELLS AMERICA INC 400 Spectrum Center Drive Suite 1400 Irvine CA 92618 USA EMAIL WEB TEL hqc inquiry qcells com www qcells com 1 949 748 59 69 ...

Отзывы: