Reactive Power Response

: The inverter supports the reactive power response mode according to 

the grid code to support the grid system.

 

-

Volt-var

: The inverter outputs the reactive 

power by the response curve according to the 

grid system voltage. This response is supported 

only in Australia and New Zealand. 

RE

A

C

TIVE PO

WER LE

VEL, Q/S        (%)

ra

te

d

−60

Absorbing

Supplying

−50

−40

−30

−20

−10

0

V

V1

V

V2

V

V3

V

V4

10

20

30

40

50

60

INVERTER VOLTAGE, V

 

-

Cos Φ (P) curve

: If the output power is 

generated 50% or higher, the inverter outputs 

the lagging reactive power according to the 

active power response curve. This response is 

supported only in Germany.

P/P

Emax

1

0.5

0.2

0.95

cos

Φ

0.95

1

over-excited

under-excited

8.4  Battery Management

• 

Backup SOC

: The minimum SOC that the battery maintains in order to supply power to the load in 

the case of Off grid.

- Battery SOC < Backup SOC (On-grid mode): Q.HOME CORE does not discharge the battery but 

only performs charging operation.

• 

Charge Management

: If the PV power is greater than the load power, the inverter charges the 

battery. If the battery SOC reaches 100 %, the battery converter stops its operation not to be 
overcharged.

• 

Discharge Management

: Discharge Management effectively prevents the battery from being 

damaged due to overcharge. If the battery SOC (State of Charge) reaches 5 % or the Backup SOC, 
it limits the battery discharge.

• 

Cell balancing

: If the inter-cell potential difference exceeds the threshold voltage, the PCS 

automatically starts cell balancing control to prevent the battery from damage due to the potential 
difference among battery cells.

• 

Parallel Connection

: In the Q.SAVE parallel connection, internal module relays is not connected 

if voltages are different between each battery module. Then, the battery management system 
automatically controls charging/discharging power of each battery to achieve the identical Q.SAVE 
voltage. When the voltage of each module becomes equal, the internal relays are connected.

 

Q.SAVE #1

Q.SAVE #2

Battery module

Relay board

Relay board

BAT 

IN

BAT 

IN

BAT 

OUT

BAT 

OUT

Battery module

Содержание Q.HOME CORE H Series

Страница 1: ...USER MANUAL Q HOME CORE H4 H5...

Страница 2: ...Q VOLT Overview 8 3 2 Q SAVE Overview 9 3 3 Specifications 10 4 Power On Off 12 4 1 Turnig On Q HOME CORE 12 4 2 Using the Dark Start button 12 4 3 Turning Off Q HOME CORE 13 5 LED Status 14 6 Using t...

Страница 3: ...de 21 7 3 Seamless Transfer 22 8 Features 23 8 1 Protection 23 8 2 Power Derating 23 8 3 Power Quality Response 23 8 4 Battery Management 24 8 5 Demand Response Modes DRMS 25 8 6 Dark Start 25 9 Maint...

Страница 4: ...ou fail to follow the instructions in this manual 1 2 Target Group Electricians and qualied technicians who are allowed to install and to connect electrical systems 1 3 Symbols Used in This Manual Thi...

Страница 5: ...s Battery storages For further information on proper use of this device contact the Q CELLS Service Hotline 2 2 Safety Precaution The following safety precautions and the warning messages described in...

Страница 6: ...m entering inside during installation and wiring 2 3 Earth Fault Alarm When an earth fault occurs the inverter stops operation and the buzzer operates for 2 minutes Note This feature is only supported...

Страница 7: ...duct 2 Disposal of Q SAVE When this crossed out wheeled bin symbol is attached to batteries accumulators of your product it means they are covered by European Directive 2006 66 CE This symbol may be c...

Страница 8: ...d Load port 2 LED indicator 9 Communication port 3 Inner cover 10 BMS Connector 4 Wiring cover 11 USB Port 5 Battery power connector 12 LAN DRM port 6 PV switch 13 Wi Fi LTE Dongle port 7 PV connector...

Страница 9: ...oduct Description 3 2 Q SAVE Overview 7 8 9 2 1 3 5 6 4 1 Front cover 6 BMS board 2 Inner cover 7 Battery DC Switch 3 Wiring cover 8 Battery Power Connector 4 Battery module 9 BMS Connector 5 Relay bo...

Страница 10: ...Korea PV DATA DC Max Input Usable Power kWp 8 0 4 0 per MPPT Max Input Voltage Vdc 600 Start Input Voltage MPP Voltage Range V 120 90 to 550 Number of Independent MPPTs 2 Number of DC Input Pairs per...

Страница 11: ...harge Power kW 2 8 to 3 8 1 Battery Pack 5 2 Battery Pack Max Discharge Power kW 3 3 to 4 5 1 Battery Pack 5 DE 4 6 2 Battery Pack 3 3 to 4 5 1 Battery Pack 5 2 Battery Pack Converter Technology Non i...

Страница 12: ...3 Turning on the battery DC switch 4 2 Using the Dark Start button To turn on Q HOME CORE when there are no PV and Grid Press the Dark Start button for about 10 seconds Once the power is supplied and...

Страница 13: ...on to avoid deep discharge of the battery Alternatively the device can also be switched off completely To turn off the Q HOME CORE 1 Turning off the battery DC switch 2 Turning off the PV switch 3 Tur...

Страница 14: ...rging in online mode Flashing Standby in online mode Magenta Solid Charging or discharging in offline mode Flashing Standby in offline mode Green Solid Charging or discharging in off grid mode Flashin...

Страница 15: ...rope 2 Tap SAVE 3 Enter your ID and password and tap LOGIN or use a social login Note If you don t have your account yet select Don t Have an Account Register at the bottom of the login screen to regi...

Страница 16: ...Tab 1 Energy Flow Inventory Flow Updates the PV generation amount the battery charging discharging amount the household power consumption amount and the grid system power information every 3 seconds...

Страница 17: ...Consumption Household power consumption amount Charging Battery charging amount Discharging Battery discharging amount Feedin Power sales to the grid system Demand Power purchase from the grid system...

Страница 18: ...em E mail password etc 4 Tap SAVE 6 7 Viewing the Installation Information 1 Tap on the right top of the screen 2 Tap Installation Info 3 Selet the desired tab Product Provides the product information...

Страница 19: ...s such as blackout By setting the Energy Backup option you can set the battery to discharge only up to the specific amount under normal circumstances and backup energy can be used when blackout occurs...

Страница 20: ...Critical load Main Load power the battery discharges to provide the short household load energy If the PV battery power is less than the load power the short load power is supplied from the grid syste...

Страница 21: ...d Main Load power the battery discharges to supply the short energy to the critical load If PV battery power is less than the load power the inverter stops operating Q VOLT Q SAVE With current No curr...

Страница 22: ...grid system power is restored during the off grid operation the inverter is automatically connected to the grid system after a certain period and operates in the on grid mode Q VOLT Q SAVE Q VOLT Q SA...

Страница 23: ...grid code to support the grid system Volt Watt The input and output active powers are limited by the response curve according to the inverter operation mode charging and discharging and the grid syst...

Страница 24: ...performs charging operation Charge Management If the PV power is greater than the load power the inverter charges the battery If the battery SOC reaches 100 the battery converter stops its operation...

Страница 25: ...d is no more than 75 of the rated power DRM 4 The import power from the grid is no more than 100 of the rated power but subject to the constrains from other active DRMs DRM 5 The export power from the...

Страница 26: ...eaning the Cover Qualified Person Only If Q HOME CORE is dirty clean the enclosure the enclosure cover and the LED using only clean water and a soft cloth Ensure that the Q HOME CORE is free of dust f...

Страница 27: ...27 10 Full Warranty Download the Q HOME CORE warranty document from the QCELL web page or the following link or the QR code and make sure to read it carefully...

Страница 28: ...e Haberkorn GmbH Augustenh he 7 06493 Harzgerode TEL 49 0 39484 9763 85 EMAIL q home e service48 com Hanwha Q CELLS Australia Pty Ltd Suite 1 Level 1 15 Blue Street North Sydney NSW 2060 Australia TEL...

Отзывы: