![Qcells Q.HOME CORE H Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/qcells/q-home-core-h-series/q-home-core-h-series_user-manual_3126337020.webp)
20
7
Operating Mode
7.1 ON-Grid Mode
1
Daytime On-Grid
•
PV Power > Load Power
: The PV power is preemptively supplied to the household load (Critical
load + Main Load), and then it charges the battery. If PV energy remains, it is operated according to
the operation mode as below.
-
Self consumption mode
: The remaining PV energy is supplied to Grid.
-
Zero export mode
: Q.VOLT decreases the PV generation amount.
•
PV Power < Load Power
: If the PV power is less than the household load (Critical load + Main
Load) power, the battery discharges to provide the short household load energy. If the PV + battery
power is less than the load power, the short load power is supplied from the grid system.
Q.VOLT
Q.SAVE
With current
No current
Charging
Discharging
Energy
Meter
Recloser
Grid
Critical Load
Main Load
PV power generation
2
Nighttime On-Grid
While the battery discharges, it supplies energy to the load. If the battery power is not enough to
supply energy to the household load (Critical load + Main Load), the short power is supplied from the
grid system.
Q.VOLT
Q.SAVE
With current
No current
Discharging
Critical Load
Main Load
Energy
Meter
Recloser
Grid
3