background image

 

 
 

Water Care 

Daily Checklist 

1.

 

Test for proper bromine or chlorine level. Proper 
bromine level should be maintained at 2.0 - 4.0 PPM. 

2.

 

Test pH levels and adjust if needed. If you are having 
difficulty keeping pH properly balanced, it may be an 
indication that total alkalinity needs adjusting. Have 
your dealer test the water and adjust if needed.  

Weekly Checklist

  

 

1.

 

Add Clarifier to help the filter remove small 
particles and to retain water clarity. 

 

2.

 

Add Chelating Agent to protect your equipment 
against stains, scale and rust.  

 

3.

 

For spas located outdoors or subject to a great deal 
of sunlight add Algaecide to guard against algae. 

 

4.

 

Shock your spa weekly with Oxidizer to remove 
contaminants such as ammonia, body oils and 
foreign matter. Unless spa water is routinely shock 
treated, contaminants will accumulate to cause eye 
and skin irritation, odors and cloudy dull water 
appearance. 

 

5.

 

To eliminate and prevent foaming, add a small amount 
of NON FOAM agent as 

needed.  

 

General Guidelines 

 
•  

NEVER MIX CHEMICALS TOGETHER

 

 
•  Add only small amounts of each chemical at a time until 
the desired level is achieved. Do not exceed dosage rates 
on label directions.  
 
•   Keep spa free of debris and cover spa when not in use. 
 
•  Circulate the water for 2-4 hours each day to maintain 
proper filtration. Clean your filter with FILTER 
CLEANER every 1-2 months.  
 
•   Remove oils and grease around water line with a 
cleaner on a weekly basis. 
 
•  In heavily used spas, water should be drained and 
refilled every two months or whenever it becomes 
difficult to maintain proper chemical levels.  
 

Filter Maintenance 
As with any water filtering system, the filter cartridges 
may become clogged with particles or with calcification 
that will result in reduced water flow. In your QCA Spa, it 
is important to maintain a clean, unobstructed filtering 
system. This not only provides the maximum performance 
from the hydrotherapy jets, but allows the 24 hour 
filtration system to function effectively. We recommend the 
filter cartridges be cleaned (either spraying clean with 
water or soaking to dissolve minerals) EVERY MONTH. 
 
WARNING: 

 

 Failure to maintain the cartridges in a 

clean, unobstructed manner will result in reduced water 
flow through the heater assembly which may cause the 
pump to stop operating generating error codes “OH” 
“DR” “DY” “HH”. If this occurs during sub-freezing 
temperatures and goes unnoticed, the spa water may 
freeze. Any damage to the spa (from freezing) which is a 
direct cause of poor maintenance will not be covered by 
warranty.     

 

Removing a Filter Cartridge 
The cartridge of the in-line filter must be removed for 
cleaning. This is accomplished as follows: 
 

1.

 

Remove floating telescope lid. 

2.

 

Twist and lift out basket to reveal the cartridge. 

3.

 

Remove the filter cartridge from the housing and 
clean, or replace it with a new cartridge. 

 
 
 
 

 
 

NOTE: 

Not maintaining your water can result in 

damage of your spa jets, filter, etc. This damage, 
due to incorrect water maintenance is not covered 
under warranty.

 
Cleaning the Filter Cartridge 

 
1.

 

Hold the cartridge in an upright position and spray 
downward into the pleats of the fabric with a garden 
hose to flush away debris.  Cleaning will be easier if 
the garden hose nozzle can be adjusted to a single jet 
spray.  

2.

 

After hosing off the cartridge, it is highly 
recommended that the cartridge be allowed to soak in a 
filter-cleaning solution available through your local 
dealer. Soak the cartridge for 24 hours to remove body 
oils and body lotions that become impregnated in the 
cartridge fabric during filtration. Rinse the cartridge 
thoroughly before placing it back in the filter housing. 

 

NOTE

: We recommend after cleaning to allow the    filter 

to dry before replacing. We suggest having an extra filter 
on hand. 
 
3.

 

If the cartridge is coated with algae or bacteria or a 
hard, solid material, (which it may indicate a calcium 
build-up) on the fabric. This build-up can be removed 
by soaking the cartridge. A cartridge cleaning solution 
is available through your QCA dealer. When using this 
solution, follow instructions provided on label. 

4.

 

Clean the filter housing.       

5.

 

Return the filter cartridge to the housing and replace 
basket and floating telescope lid. 

 

Vacation Care Instructions 

If you plan to be away, follow these instructions to 
maintain the water quality: 
 
Short Time Periods (3-5 Days): 

1.

 

Adjust the pH by following the instructions outlined in 
the water quality and maintenance section. 

 

2.

 

Sanitize the water by following the “super-chlorinating” 
procedures and lock your thermal

 cover in place using the 

tie-downs. 

 
3.

 

Upon your return, sanitize the water (superchlorinate, if 
necessary) and balance the 

pH. 

 

IMPORTANT NOTE:

 

Spa water oxidizers such as 

dichlor chlorine maintain their level of effectiveness 
substantially longer in cool water than in hot water. 

 

Long Time Periods  (4-15 Days) 
Prior to leaving:

 

 
1.   Adjust the pH as required. 
 
2.   Sanitize the water by following the SUPER- 
CHLORINATION procedures. 
 

                                                                       

Содержание VS501 PAK (VL260 TOPSIDE)

Страница 1: ...s important for you to take a few moments and get acquainted with your new spa operation Please keep this manual available for references QCA Spas would like to congratulate you on your purchase and we sincerely hope you enjoy your QCA Spa SERIAL NUMBER _____________ 18 DIGIT SPA NUMBER ____________ QCA Spa VS501 VL260 10 08 Technical Service Toll Free 866 998 0148 ...

Страница 2: ...n 3 Initial Start Up 5 Installation Instructions 4 115 230v Installations 4 Prevention of Freezing 9 Refilling your Spa 7 Removing the Box Filter Cartridge 8 Spa and Cabinet Maintenance 9 Spa Location 4 Spa Top Side Control 5 Troubleshooting 9 UL Instructions 3 Vacation Care 8 Warranty Information 7 8 Water Care Program 8 9 Winterizing 9 ...

Страница 3: ...es to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature regulating devices may vary as much as 5 F 3 C d The use of alcohol drugs or medication before or during spa or hot tub use may lead to unconsciousness with the possibility of drowning e Persons suffering from obesity or with a medi...

Страница 4: ...ons Electrical General Prior to performing any service to the spa package turn OFF ALL primary electric power at the main circuit breaker or disconnect panel Opening the front cover of the electrical control box can make all field electrical connections All electrical connections to this spa package must be accomplished by a qualified electrician in accordance with the National Electric Code or th...

Страница 5: ...ht Press the Light button to turn the light on and off If left on the light automatically turns off after 4 hours Standard Mode is programmed to maintain the desired temperature Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes Preset Filter Cycles The first filter cycle begins six minutes after the spa is energized The seco...

Страница 6: ...nd disappear when the heater cools Sn Sensors are out of balance If changing spa temperature it may just be temporary If flashing by itself the spa is shut down If the problem persists contact your dealer or service organization HL A significant difference between temperature sensors has been detected This could indicate a flow problem Check the water level in spa Refill if necessary If the water ...

Страница 7: ...e Water Simply siphon water from spa with garden hose A sump pump may be used to pump water from spa Use a wet dry vac to remove the remaining amount of water Refilling your Spa 1 Be sure the main breaker to your spa equipment pack is off 2 Fill spa thru the filter housing with water to proper level 3 Turn power back on spa will automatically start to run and heat water to set temperature Your Wat...

Страница 8: ...s unnoticed the spa water may freeze Any damage to the spa from freezing which is a direct cause of poor maintenance will not be covered by warranty Removing a Filter Cartridge The cartridge of the in line filter must be removed for cleaning This is accomplished as follows 1 Remove floating telescope lid 2 Twist and lift out basket to reveal the cartridge 3 Remove the filter cartridge from the hou...

Страница 9: ...soap and water solution or simply sprayed with a garden hose Use of harsh chemicals to clean the surface will cause the cabinet to discolor Troubleshooting Please Note The following corrective actions may be performed by the spa owner If the trouble cannot be corrected in the steps below please refer to your QCA Spas Inc Dealer for service Improper servicing by an unauthorized serviceman or spa ow...

Страница 10: ...Date Installed Spa Model Serial Number Warning Elderly persons infants and anyone subject to heart disease diabetes high or low blood pressure strokes epilepsy or similar afflictions should not enter a spa alone and without consulting a physician Unsupervised use by children should be prohibited Never use a spa while under the influence of alcohol anti coagulants antihistamines vasoconstrictors va...

Отзывы: