QOM-eLED+DMX
LED POWER SUPPLY 100W–300W
© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com
Specification subject to change. Rev-09-25-20
COMPLIANT
Wiring Diagram
12V - 28V DC IN
•
To connect the driver to a DC power supply unit (PSU), connect the PSU’s positive voltage supply wire to the VDC+
connector and the PSU’s negative voltage supply wire to the VDC- connector.
EXT in
•
You have the possibility to connect an external control device (0-10V control device, 10kΩ potentiometer or show selection
switch) to the driver’s Ext in+ and Ext in - connector. Configure the driver for use with an external control device over the 3 -
button user interface.
DMX in/LedSync out
•
Use these connectors when the driver is used in a DMX network. For DMX in, connect the network cable’s DMX+, DMX-
and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in
shield connector respectively. For LedSync out, connect the network cable’s DMX+, DMX- and DMX shielding wire to the
LedSync out+, LedSync out- and LedSync shield connector respectively. DMX Shield must be grounded to Earth ground
at a single point external to power supply
LED groups
•
Indicates the location of the connectors for your LED groups. R(ed) represents channel 1, G(reen) represents channel 2,
B(lue) represents channel 3 and W(hite) represents channel 4. The default group color allocation can be changed over the
3-button user interface.
M
Max | Vdc+
32V | Vdc-
Ext in +
Ext in
DMX in +
DMX in -
DMX in shield
LedSync thru +
LedSync thru -
LedSync shield
TC
1
2
3
Group
Group
Group
Group
LED
-
4
LINEARdrive 180D
12-28V / 6A Direct voltage controlled LED driver
LED groups
R
R
W
R
B
G
R
R
{
12-28VDC IN
- +
2
1
0.2-1.5 mm
2
0.35 inch
0.5-1.5 mm
2
AWG 20-16
0.35 inch
AWG 24-16
VDC and LED connectors:
Other connectors:
LedSync thru +
LedSync thru -
LedSync shield
DMX in +
DMX in -
DMX in shield
Ext in +
Ext in -