background image

QOM-eLED+DMX

   

LED POWER SUPPLY 100W–300W

© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com 

Specification subject to change. Rev-09-25-20

COMPLIANT

Wiring Diagram

12V - 28V DC IN

• 

To connect the driver to a DC power supply unit (PSU), connect the PSU’s positive voltage supply wire to the VDC+ 

connector and the PSU’s negative voltage supply wire to the VDC- connector.

EXT in

• 

You have the possibility to connect an external control device (0-10V control device, 10kΩ potentiometer or show selection 

switch) to the driver’s Ext in+ and Ext in - connector. Configure the driver for use with an external control device over the 3 - 

button user interface.

DMX in/LedSync out

• 

Use these connectors when the driver is used in a DMX network. For DMX in, connect the network cable’s DMX+, DMX- 

and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in 

shield connector respectively. For LedSync out, connect the network cable’s DMX+, DMX- and DMX shielding wire to the 

LedSync out+, LedSync out-  and LedSync shield connector respectively. DMX Shield must be grounded to Earth ground 

at a single point external to power supply

LED groups

• 

Indicates the location of the connectors for your LED groups. R(ed) represents channel 1, G(reen) represents channel 2, 

B(lue) represents channel 3 and W(hite) represents channel 4. The default group color allocation can be changed over the 

3-button user interface.

M

Max | Vdc+

32V | Vdc-

Ext in +

Ext in

DMX in +

DMX in -

DMX in shield

LedSync thru +

LedSync thru -
LedSync shield

TC

1

2

3

Group

Group

Group

Group

LED

 -

4

LINEARdrive 180D

12-28V / 6A Direct voltage controlled LED driver

LED groups

R

R

W

R

B

G

R

R

{

12-28VDC IN

- +

1

0.2-1.5 mm

2

0.35 inch

0.5-1.5 mm

2

AWG 20-16

0.35 inch

AWG 24-16

VDC and LED connectors:

Other connectors:

LedSync thru +

LedSync thru -

LedSync shield

DMX in +

DMX in -

DMX in shield

Ext in +

Ext in -

Содержание QOM-eLED Series

Страница 1: ...oduct Size1 Prim V Sec V Control Opts2 100W 200W 300W UNV 24VDC DMX BK SS 1 Size Size Max Load Watts Secondary Voltage 12 24VDC Max Prim Amps 120V Max Prim Amps 277V 100W 1x100W 24VDC 0 95A 0 40A 200W 2x100W 24VDC 1 90A 0 80A 300W 3x100W 24VDC 2 85A 1 20A 2 Options BK Black Powder Coat Finish Standard SS 316 Marine Grade Stainless Steel Voltage Drop Chart VDC Watts W 10 AWG 5 6mm2 12 AWG 3 3mm2 14...

Страница 2: ...38 Low Voltage Landscape Lighting Systems ANSI UL Standard 8750 Light Emitting Diode LED Equipment for Use in Lighting Products CSA Std C22 2 No 250 13 14 Light Emitting Diode LED Equipment for Lighting Applications 14 5 15 4 9 22 BOTTOM TRAY PRIMARY SECONDARY LED DRIVER 120V 277V 120V 277V LED DRIVER 120V 277V LED DRIVER 120V 277V W B G R 24 W B G R 24 W B G R 24 DMXIN NEU HOT GND DMXOUT A B C A ...

Страница 3: ...750 CSA C22 2 No 250 7 07 CSA C22 2 No 250 0 08 CSA C22 2 No 250 13 14 Input 24VDC Input Voltage Vrms 120 230 277 Input Current max Arms 0 98 0 51 0 43 Inrush Current max Apk 20 Input Frequency Hz 50 60 Input Power W 177 Output RGB RGBW Output Voltage nom V 24 24 Output Current A 2 0 1 5 Output Power Wmax 100 100 Environmental Min Nom Max THD 20 PF 0 90 Case Temp ºC 90 200us event Efficiency Load ...

Страница 4: ...ge white orange and brown wire in a CAT5 cable to the DMX in DMX in and DMX in shield connector respectively For LedSync out connect the network cable s DMX DMX and DMX shielding wire to the LedSync out LedSync out and LedSync shield connector respectively DMX Shield must be grounded to Earth ground at a single point external to power supply LED groups Indicates the location of the connectors for ...

Страница 5: ... 09 29 20 Mounting Options Housing BOTTOM VIEW ISOMETRIC VIEW 1 36 KNOCKOUT 4X FOR 1 FITTINGS 1 07 KNOCKOUT 5X FOR 3 4 FITTINGS 4 90 14 5 15 4 9 22 4 90 NOTE To order additional lengths of wire for connection in the secondary Please call factory for availability QOM must be installed as shown Pole Mount Surface Wall Mount 2 00 0 25 1 4 x2 wood screw or LAG bolt recommened 1 82 3 38 3 14 ...

Страница 6: ... in DMX in DMX in DMX in shield LedSync thru LedSync thru LedSync shield LINEARdrive 180D 12 28V 6A Direct voltage controlled LED driver DMX in shield LedSync shield DMX in LedSync thyu DMX in LedSync thyu Blue Wire Blue LED Red Wire Red LED Green Wire Green LED White Wire White LED Black Wire 24V A C LED DRIVER 2 120 277V B M GND NEU SECONDARY PRIMARY DMX Shield DMX DMX iQ LED Blue Blue White Whi...

Страница 7: ... SWIT display off M External input EXT INP LOG LIN Dimming curve M DIM CURV 00 20 M display off SHOW M M M 99 99 0 255 Intensity Speed Show SPD INT M HUE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL The colour menu depends on the LED group setting...

Страница 8: ...r exterior Blue Wire Blue LED Red Wire Red LED Green Wire Green LED White Wire White LED Black Wire 24V A C LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B M M M SECONDARY PRIMARY DMX Shield DMX DMX M LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V NEU GND HOT GND HOT NEU A B C W B G R 24 W B G R 24 W B G R 24 DMX IN DMXOUT A B C LED LED LED GND DMX DMX ...

Страница 9: ...local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the product and the hazards involved Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply is to be installed in a location where it is not likely to be contacted by non electricians To avoid a hazard to children account for all p...

Отзывы: