background image

QOM-eLED+DMX

   

LED POWER SUPPLY 100W–300W

© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com 

Specification subject to change. Rev-09-25-20

COMPLIANT

Part Number Builder

QOM-eLED is Q-Tran's exterior rated surface mounted electronic 

DMX power supply, utilizing a 100W constant voltage LED Driver 

from Thomas Research and the LINEARdrive DMX decoder from 

eldoLED. With the ability to fit up to 300W of power and control in 

one enclosure, this unit provides plenty of flexibility and comes with 

all decoders prewired together with terminal blocks for landing your 

RGB or RGBW wires.

Technical Information

QOM-eLED

UNV

24VDC

DMX

Product

Size

1

Prim. V

Sec. V

Control

Opts

2

100W

200W

300W

UNV

24VDC

DMX

BK

SS

Size

Size

Max Load  

(Watts)

Secondary 

Voltage

(12/24VDC)

Max Prim Amps 

@ 120V

Max Prim Amps 

@ 277V

100W

1x100W

24VDC

0.95A

0.40A

200W

2x100W

24VDC

1.90A

0.80A

300W

3x100W

24VDC

2.85A

1.20A

Options

BK

  Black Powder Coat Finish (Standard)

SS

 

316 Marine Grade Stainless Steel

Voltage Drop Chart

VDC

Watts 

(W)

10 AWG 

(5.6mm2)

12 AWG 

(3.3mm2)

14 AWG 

(3.0mm2)

16 AWG 

(1.3mm2)

18 AWG 

(0.78mm2)

20 AWG 

(0.50mm2)

22 AWG 

(0.33mm2)

24 AWG 

(0.22mm2)

26 AWG 

(0.13mm2)

24

17
25
40
80

100

897'
567'
309'
130'

84'

564'
356'
194'

82'
53'

355'
224'
122'

51'
33'

223'
141'

77'
32'
21'

140'

88'
48'
20'
13'

88'
56'
30'
13'

8'

55'
35'
30'

8'
5'

35'
22'
12'

5'
3'

22'
14'

7'
3'

*Distances are based on a 5% Voltage drop max.

• This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved

Содержание QOM-eLED Series

Страница 1: ...oduct Size1 Prim V Sec V Control Opts2 100W 200W 300W UNV 24VDC DMX BK SS 1 Size Size Max Load Watts Secondary Voltage 12 24VDC Max Prim Amps 120V Max Prim Amps 277V 100W 1x100W 24VDC 0 95A 0 40A 200W 2x100W 24VDC 1 90A 0 80A 300W 3x100W 24VDC 2 85A 1 20A 2 Options BK Black Powder Coat Finish Standard SS 316 Marine Grade Stainless Steel Voltage Drop Chart VDC Watts W 10 AWG 5 6mm2 12 AWG 3 3mm2 14...

Страница 2: ...38 Low Voltage Landscape Lighting Systems ANSI UL Standard 8750 Light Emitting Diode LED Equipment for Use in Lighting Products CSA Std C22 2 No 250 13 14 Light Emitting Diode LED Equipment for Lighting Applications 14 5 15 4 9 22 BOTTOM TRAY PRIMARY SECONDARY LED DRIVER 120V 277V 120V 277V LED DRIVER 120V 277V LED DRIVER 120V 277V W B G R 24 W B G R 24 W B G R 24 DMXIN NEU HOT GND DMXOUT A B C A ...

Страница 3: ...750 CSA C22 2 No 250 7 07 CSA C22 2 No 250 0 08 CSA C22 2 No 250 13 14 Input 24VDC Input Voltage Vrms 120 230 277 Input Current max Arms 0 98 0 51 0 43 Inrush Current max Apk 20 Input Frequency Hz 50 60 Input Power W 177 Output RGB RGBW Output Voltage nom V 24 24 Output Current A 2 0 1 5 Output Power Wmax 100 100 Environmental Min Nom Max THD 20 PF 0 90 Case Temp ºC 90 200us event Efficiency Load ...

Страница 4: ...ge white orange and brown wire in a CAT5 cable to the DMX in DMX in and DMX in shield connector respectively For LedSync out connect the network cable s DMX DMX and DMX shielding wire to the LedSync out LedSync out and LedSync shield connector respectively DMX Shield must be grounded to Earth ground at a single point external to power supply LED groups Indicates the location of the connectors for ...

Страница 5: ... 09 29 20 Mounting Options Housing BOTTOM VIEW ISOMETRIC VIEW 1 36 KNOCKOUT 4X FOR 1 FITTINGS 1 07 KNOCKOUT 5X FOR 3 4 FITTINGS 4 90 14 5 15 4 9 22 4 90 NOTE To order additional lengths of wire for connection in the secondary Please call factory for availability QOM must be installed as shown Pole Mount Surface Wall Mount 2 00 0 25 1 4 x2 wood screw or LAG bolt recommened 1 82 3 38 3 14 ...

Страница 6: ... in DMX in DMX in DMX in shield LedSync thru LedSync thru LedSync shield LINEARdrive 180D 12 28V 6A Direct voltage controlled LED driver DMX in shield LedSync shield DMX in LedSync thyu DMX in LedSync thyu Blue Wire Blue LED Red Wire Red LED Green Wire Green LED White Wire White LED Black Wire 24V A C LED DRIVER 2 120 277V B M GND NEU SECONDARY PRIMARY DMX Shield DMX DMX iQ LED Blue Blue White Whi...

Страница 7: ... SWIT display off M External input EXT INP LOG LIN Dimming curve M DIM CURV 00 20 M display off SHOW M M M 99 99 0 255 Intensity Speed Show SPD INT M HUE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL The colour menu depends on the LED group setting...

Страница 8: ...r exterior Blue Wire Blue LED Red Wire Red LED Green Wire Green LED White Wire White LED Black Wire 24V A C LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B M M M SECONDARY PRIMARY DMX Shield DMX DMX M LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V NEU GND HOT GND HOT NEU A B C W B G R 24 W B G R 24 W B G R 24 DMX IN DMXOUT A B C LED LED LED GND DMX DMX ...

Страница 9: ...local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the product and the hazards involved Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply is to be installed in a location where it is not likely to be contacted by non electricians To avoid a hazard to children account for all p...

Отзывы: