CLASS:  

3425 - 15

               

3425 - 95

LOW VOLTAGE LIGHTING SYSTEM & 

LANDSCAPE LIGHTING SYSTEMS

3402 - 15

3402 - 95

PROJECT NAME 

DATE

TYPE

NOTE

COMPANY

1

WIRE LENGTH TABLE

*

Distances are based on a 5% Voltage drop max.

● This product must be installed in accordance with the applicable installation code by a person familiar with the 

   construction and operation of the product and the hazards involved.

2 Secondary Voltage 

3 Control

4 Housing

Ordering Example

    

ORDERING GUIDE 

QOM-DRIVE

-

+

-

-

Model

  Size           Sec. V          Control  

     

Housing

1

2

3

4

12V

DC

DMX

DALI

24V

DC

120

W

100

W

200

W

2X60W

1X100W

2X100W

12VDC

24VDC

24VDC

1.05A

2.10 A

0.45A

0.90A

2.10A

0.90A

60

W

1X60W

12VDC

1.05A

0.45A

QOM-DRIVE-100-24V+DMX

1 Size

Max Load

Secondary

Max Prim.

Max Prim.

(Watts)

Voltage (12/24VDC)

Amps @ 120V

Amps @ 277V

BK 

Black Powder Coat 

      Finish ( Standard ) 

SS 

316 Marine Grade 

       Stainless Steel

The Q-Tran QOM-Drive with available DMX or DALI control and dimming options, is an ideal 

solution for nearly all interior or exterior color changing lighting applications.This electronic 

outdoor power supply, utilizes eldoLED LINEARdrive drivers and is suitable for indoor and 

outdoor use, in 12VDC or 24VDC constant voltage options, and is capable of up to 200 Watts of 

flicker free power within a single enclosure.The QOM-Drive comes pre-wired to meet any need, 

with terminal blocks for all input and output connections to greatly reduce installation time. 

DALI

Use these connectors to connect the driver to a DALI network. Always combine 

a DA+ and DA- connector 

for either data input or data output. A separate DALI power supply is required to power the DALI bus.  

DMX in/LedSync out

Use these connectors when the driver is used in a DMX network. For DMX in, 

connect the network 

cable’s DMX+, DMX- and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) 

to the DMX in+, DMX in- and DMX in shield connector respectively. For LedSync out, connect the network 

cable’s DMX+, DMX- and DMX shielding wire to the LedSync out+, LedSync out-  and LedSync shield 

connector respectively. DMX shielding wire must be grounded to Earth ground external to power supply.

FEATURES

● 

DMX or DALI controllable

● Surface mount capable

● Suitable for dr

y, damp and wet locations

● Suitable for indoor or outdoor use
● 

4x 12/24V controllable outputs per driver

● 

Standby power: < 0.5W 

● 

Built-in surge protection: 3kV (L to N), 4kV (L/N to GND)

    

Low Voltage Lighting Systems

    :  CSA class 3425-15 and class 3425-95                   

   :  CSA standard C22.2 No. 250.0-08 - Luminaires                   

    :  ANSI/ UL standard 2108 - Low voltage lighting systems

    :  ANSI/ UL standard 8750 - Light emitting diode (LED) equipment for use in lighting products       

    :  CSA Std C22.2 No 250.13-14 - Light emitting diode (LED) equipment for lighting applications       
   

 LED Landscape Lighting Systems

   :  CSA class 3402-15 and class 3402-95

   :  CSA standard C22.2 No. 250.7-07 - Extra-Low-Voltage Landscape lighting systems                

     

    :  ANSI/ UL standard 1838 - Low voltage landscape lighting systems

  :  ANSI/ UL standard 8750  - Light emitting diode (LED) equipment for use in lighting products 

    :  CSA Std C22.2 No 250.13-14  - Light emitting diode (LED) equipment for lighting applications

● 

Flicker free operation

● 

Efficiency: 90% at full load, 

    ≥ 87% above 50W output
● 

Class 2 output  

 

● 

Power factor: > 0.94

● 

THD @ full load : <10%

● 

3 year warranty

● CSA #239924

QOM-DRIVE

DALI

DMX

Watts

(W)

12

           

315’         198’          125’            78’             49’            31’             19’            12’             7’     

25

           

115’           72’            45’            28’             18’             11’              7’              4’             4’

60

              

7’             4’              3’

17

           897’         564’          355’          223’           140’             88’            55’            35’            22’

25

           567’         356’          224’          141’             88’             56’            35’            22’            14’

 40

           309’         194’          122’            77’             48’             30’            30’            12’              7’

 80

           130’           82’            51’            32’             20’             13’              8’              5’              3’

100

            84’           53’            33’            21’             13’               8’              5’              3’

VOLTAGE DROP CHART

VDC

12

24

 10 AWG       12 AWG      14 AWG       16 AWG       18 AWG      20 AWG        22 AWG       24 AWG     26 AWG

 (5.6mm

Р

)       (3.3mm

Р

)      (3.0mm

Р

)       (1.3mm

Р

)     (0.78mm

Р

)      (0.50mm

Р

)     (0.33mm

Р

)      (0.20mm

Р

)     (0.13mm

Р

)

14.5"

15.4"

9.22"

PRIMARY

SECONDARY

eldoLED POWERdrive 100/S

M

_

+

120-277VAC

50-60Hz

DA

-

+

DA

-

+

~

~

1

2

eldoLED POWERdrive 100/S

M

_

+

120-277VAC

50-60Hz

DA

-

+

DA

-

+

~

~

1

2

W B G R +24

A

W B G R +24

B

A

B

DMX IN

DMXOUT

NEU

GND

HOT

1.07"

1.36"

4.90"

5

  Knockouts of 

1.07"

Hole for 

3/4"

 fitting

4

  Knockouts of 

1.36"

Hole for 

1"

 fitting

Содержание QOM-DRIVE Series

Страница 1: ...ced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a hazard to children account for all parts and destroy all packaging materials Risk of Fire Electric Shock Transformer should be installed by a Licensed electrician in accordance with the N E C and all local codes in force INSTALLATION INSTRUCTIONS Must be installed...

Страница 2: ...ble to the DMX in DMX in and DMX in shield connector respectively For LedSync out connect the network cable s DMX DMX and DMX shielding wire to the LedSync out LedSync out and LedSync shield connector respectively DMX shielding wire must be grounded to Earth ground external to power supply FEATURES DMX or DALI controllable Surface mount capable Suitable for dry damp and wet locations Suitable for ...

Страница 3: ...R 3 4 FITTINGS 4 90 NOTE To order additional lengths of wire for connection in the secondary please call factory for availability QOM must be installed as shown Pole Mount Surface Wall Mount 2 00 0 25 1 4 x2 wood screw or LAG bolt recommened 1 82 3 38 3 14 2020 Q Tran Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com ...

Страница 4: ... don t have a controller yet how can I keep my lights on Change the mode to COLR This allows to manually set a specific color to be on Adjust the Hue or WHIT to achieve the desired color This sets that specific color 3 My LEDs aren t coming out the right color They look like white has been added in Verify the network resolution NETW RES Default is 8 BT Check your DMX programming Stick controllers ...

Страница 5: ... sec W 1 sec RGBW 1 sec display off M LOCK M Lock driver 5 sec NO SOFT HARD M display off RE SET Reset M 5 sec Press menu PRES MENU The colour menu depends on the LED group settings you have selected in step 2 3 Standalone operation Colour or 00 20 display off display off display off SHOW M M M 99 99 0 255 Intensity Speed Show SPD INT M Standalone operation Show or M M 1 512 Network resolution DMX...

Страница 6: ...A DA 1 2 Red Red Green Green Blue Blue White White Black 24V M _ 120 277VAC 50 60Hz DA DA 1 2 LED R G B W 24V R G B W 24 A R G B W 24 B DMX OUT DMX IN GND HOT NEU NEU GND HOT A B LED LED GND DMX DMX Red Blue Green To next power supply for exterior QOM DRIVE 2020 Q Tran Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com ...

Страница 7: ...e VDC Nominal Output Wattage W Input Current A QOM DRIVE 100 QOM DRIVE 200 QOM DRIVE 120 120 1 05 2 10 50 60 50 60 24 24 QOM DRIVE 60 QOM DRIVE 120 120 120 0 67 1 30 50 60 50 60 12 12 100 200 60 120 4 7UDQ QF Q TRAN INC MILFORD CT U S A 203 367 8777 WWW Q TRAN COM 66 3425 15 3425 95 3402 15 3402 95 120V INPUT VOLTAGE OUTPUT VOLTAGE DMX 24V 12V DALI CONTROL TYPE LOW VOLTAGE LIGHTING SYSTEM LED LAND...

Отзывы: