7
•
NEVER
use a damaged hose, which
can result in hose failure or rupture and
cause an injection injury or other
serious bodily injury or property
damage. Before each use, check entire
hose for cuts, leaks, abrasions, bulging
of the cover, or damage or movement
of couplings. If any of these conditions
exist, replace the hose immediately.
•
NEVER
use tape or any device to try to
mend the hose as it cannot contain the
high pressure fluid.
NEVER ATTEMPT
TO RECOUPLE THE HOSE.
A high
pressure hose is not possible to
recouple.
GROUNDING
•
Ground the sprayer & other
components in the system to reduce
the risk of static sparking, fire or
explosion which can result in serious
bodily injury and property damage. For
detailed instructions on how to ground,
check your local electrical code.
•
ALWAYS
ensure switch is in
OFF
position before plugging unit in.
Always Ground All of These
Components:
1. Sprayer:
plug the power supply cord,
or extension cord, each equipped with
an undamaged three-prong plug, into a
properly grounded outlet.
DO NOT
USE AN ADAPTER
. Use only a 3 wire
extension cord that has a grounding
plug, and a receptacle that will accept
the grounding plug on the product.
Make sure your extension cord is in
good condition. When using an
extension cord, be sure to use one
heavy enough to carry the current your
product will draw. If in doubt, use the
next heavier gauge.
2. Fluid hose:
use only grounded hoses.
3. Spray gun or dispensing valve:
grounding is obtained through
connection to a properly grounded
fluid hose and pump.
4. All solvent pails must be conductive
metal material and properly
grounded. Do not place on a non
conductive insulating surface unless
a ground wire is added to a true
earth such as a metal water pipe.
ALWAYS
ensure fire extinguishing
equipment is readily available and
properly maintained.
FLUSHING SAFETY
WHEN SPRAYING & CLEANING WITH
FLAMMABLE PAINTS AND THINNERS
1. When spraying with flammable liquids,
the unit must be located a minimum of
25 feet away from the spraying area in
a well ventilated area. Ventilation must
be sufficient enough to prevent the
accumulation of vapors.
2. To eliminate electrostatic discharge,
ground the spray unit, paint bucket &
spraying object. See GROUNDING.
Use only high pressure airless hoses
approved for 3000 psi which is
conductive.
3. Remove the spray tip before flushing.
Hold the metal part of the gun firmly to
the side of a metal pail & use the
lowest possible fluid pressure during
flushing.
4. Never use high pressure in the cleaning
process. USE MINIMUM PRESSURE.
5. Do not smoke in spraying/cleaning
area.
•
NEVER
use cleaning solvents with
flash points below 140 degrees F.
Some of these are: acetone, benzene,
ether, gasoline, naptha. Consult your
supplier to be sure.