background image

6

7

Unlike conventional security cameras, 
PTZ cameras require an address and a 
connection speed to be set in order for 
them to properly operate. The default 
settings for this camera are an address of 
“1” and a baud rate of 2400 and using the 
Pelco-D protocol. However, if your camera 
came as part of a bundle, its address may 
have been set to something other than “1”. 
Check the 

Quick Install Poster 

that came with 

your bundle for specific details. If you are 
connecting the camera in accordance to the 
instructions included with the bundle, you 
should not have to change any of its settings. 
In either case, if you are only using a single 
PTZ camera you generally do not have to 
make any changes and you may proceed to 
the next section. Please consult your DVR’s 
manual for required settings.

SETTING BAUD RATE AND ADDRESS

Remove Screws (x6)

Remove Collar

Remove Collar

If you need to change your camera’s settings, they are made using a DIP (dual in-line package) 
switch panel located within the camera itself. In general, it is easier to do this before connecting 
the camera, but in some cases, you may need to change settings while the camera is 
connected to the DVR. In this case, please make a temporary connection by following the 
procedures laid out in the next section, 

Connecting the Camera

. Please be advised that 

adjusting these settings after the camera is mounted can be difficult due to the panel potentially 
being inaccessible because of location, position, etc.
To access the panel, one must remove the clear dome by first twisting the metal collar around 
the dome counterclockwise and then removing the six screws securing the plastic dome to 
the camera. Take care to not scratch the clear dome while removing it. The circuit board on 
which the DIP switches are mounted is visible below the camera in the bottom picture.
DIP switches are binary - meaning that they are either On (“1”) or Off (“0”). Different 
combinations of ones and zeroes on the board produce different settings. On the QD6531Z, 
there are a total of 10 DIP switches but only the first nine have any effect. The first six are for 
setting the address of the camera while positions 7 and 8 control the baud rate - which is 
the speed in bits per second at which the DVR communicates with the camera for control. 
Position 9 is used to set which communications protocol the camera will use - either Pelco-D 
or Pelco-D.
Your camera is set to a baud rate of 2400. This will allow you to effectively control the camera 
up to 3,000 feet away. Areas with electronic interference may require heavier or shielded 
cabling. The higher the setting (may be required by some DVRs), the shorter the control 
distance. 

ON

1 2 3 4 5 6 7 8 9 10

Camera Address

Baud

Rate

N/A

Comm

Protocol

SETTING BAUD RATE

Baud Rate

Switch Number (BIT)

7

8

1200bps

1

1

2400bps

0

1

4800bps

1

0

9600bps

0

0

SETTING PROTOCOL

Protocol

Switch 

Number 9

Pelco-D

1

Pelco-P

0

SETTING CAMERA 
ADDRESS

NOTE!

  Some  DVRs  may  require  specific 

connection  speeds.  Check  your  system’s 
manual for the proper settings.

Address Switch

(8 digits)

Code 1  2  3  4  5  6

1

1  0  0  0  0  0

2

0  1  0  0  0  0 

3

1  1  0  0  0  0 

4

0  0  1  0  0  0 

5

1  0  1  0  0  0

6

0  1  1  0  0  0

7

1  1  1  0  0  0

8

0  0  0  1  0  0

9

1  0  0  1  0  0

10

0  1  0  1  0  0

11

1  1  0  1  0  0

12

0  0  1  1  0  0

13

1  0  1  1  0  0

14

0  1  1  1  0  0

15

1  1  1  1  0  0

16

0  0  0  0  1  0

Address

EXAMPLE

The illustration below shows the settings for a camera with:

An address Channel 16 

A baud rate of 2400 

Using the Pelco-D communication protocol.

Содержание QD6531Z

Страница 1: ...1 User Manual MODEL QD6531Z QD6505P Outdoor Intelligent Pan Tilt Zoom Dome Camera with 3x Optical Zoom and Pan Tilt Dome Camera...

Страница 2: ...ditional service warranty covering all hardware for 12 months from the date of purchase Additionally our products also come with a free exchange policy that covers all manufacturing defects for one mo...

Страница 3: ...e the time to read and follow all instructions and pay attention to alerts as shown below INTRODUCTION NOTE Text in blue boxes with the Information icon offer additional guidance and explanations abou...

Страница 4: ...the plastic dome to the camera Take care to not scratch the clear dome while removing it The circuit board on which the DIP switches are mounted is visible below the camera in the bottom picture DIP...

Страница 5: ...d are labeled They are also pre installed into a block which plugs into a matching receptacle on the extension cable The control wire leads at the other end of the extension cable must be inserted int...

Страница 6: ...area or vice versa may produce inadequate results INSTALLING THE CAMERA The above are guidelines and the optimal location for your camera will depend on your unique circumstances As a general rule th...

Страница 7: ...rounding area Up to 128 preset points can be stored on the camera As mentioned in the section on Connecting the Camera you will need to consult your DVR s manual for specifics on how to enable your sy...

Страница 8: ...08 08 All All Start Track Start Track StartAuto Scan StartAuto Scan Start Cruise Start Cruise Preset Cruise Preset Cruise Speed 5 Speed 5 preset 101 preset 101 02 02 01 01 03 03 04 04 05 05 06 06 07...

Страница 9: ...sold over 12 months ago In order to fulfill the terms of your warranty you must complete the registration process after purchasing our product To do this simply fill out the User s Information Card o...

Страница 10: ...18 Digital Peripheral Solutions Inc 8015 E Crystal Drive Anaheim CA 92807...

Отзывы: