5.1

Control Keys

The SP-350P has three control keys, as shown in Figure 2. The left (

), right (

), and ok (

) keys

are used to launch actions indicated on the LCD display directly above the keys. The labels above the keys
indicate the function associated with each key and functions can be changed in different operation modes.

5.2

Main Module On/Off

To turn on the SP-350P

: Press

momentarily and release.

To turn off the SP-350P

: Press and hold

for about three seconds. Release

when the LCD display

turns off. The SP-350P turns itself off after 60 seconds without user interaction detected. This is done to
conserve battery life.

*

NOTE

*

This auto-time off setting may be customized by the user as desired through the

uPyxis®

Mobile or Desktop App.

6

Measurement

6.1

Fluorescent Polymer Measurement

When powered on, the SP-350P will be in the Fluorescent Polymer measurement mode. The water sample
can be transferred to the sample cell using a pipette or filled directly from a faucet, sample bottle, or sample
valve.

*

NOTE

*

Special care should be taken when pouring the sample into the cell to avoid air

bubble entrainment, which can interfere with reading accuracy.

Before beginning a measurement, use the sample water to rinse the sample cell at least three times. Allow
5–10 seconds for the SP-350P to stabilize (Figure 2). For a sample containing 10 ppm Fluorescent Polymer,
the measured Fluorescent Polymer should be stabilized within the range of 9.8–10.2 ppm.

*

NOTE

*

The time required to reach a stable reading may be slightly longer if the water

sample temperature is significantly different than the environmental temperature at which
the SP-350P had been equilibrated (stored).

The SP-350P does not need to be turned off between measurements of two samples. Rinsing the sample
cell several times between samples is recommended. Ambient light does not affect the measurement. The
sample cell does not need to be covered during the measurement.

6.2

High Color and Turbidity Warning

The SP-350P has extra channels to measure sample turbidity and color which are used to automatically
compensate for any interference caused by these contaminants as high as 40–60 NTU. If the sample tur-
bidity and color values determined are too high, a measurement warning will be displayed. In such a case,
the user should pre-filter the sample for a Fluorescent Polymer measurement within the compensation
capability of the SP-350P.

SP-350P User Manual

[email protected]

| +1 (866) 203-8397

6

Содержание SP-350P

Страница 1: ......

Страница 2: ...uorescent Polymer Handheld User Manual October 12 2020 Rev 2 00 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confidentia...

Страница 3: ...8 Device Information and Diagnosis 8 8 1 Sample Cell Cleanliness Check 9 8 2 Bluetooth Connection to Devices 10 8 3 Factory Reset 10 9 Use with uPyxis Mobile App 11 9 1 Download uPyxis Mobile App 11...

Страница 4: ...13 Contact Us 18 SP 350P User Manual service pyxis lab com 1 866 203 8397 1...

Страница 5: ...elivery All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services fo...

Страница 6: ...th the cuvette are eliminated Large color graphic screen that can be read in direct sunlight 2 Specifications Table 1 SP 350P Specifications Item Specification Part Number P N 50228 Fluorescent Polyme...

Страница 7: ...ymer 100 ppb PTSA Combined Standard 500 mL 21055 Pyxis 10 ppm Fluorescent Polymer Calibration Standard 500 mL 21054 Pyxis 20 ppm Fluorescent Polymer Calibration Standard 500 mL 21053 Pyxis Handheld Cl...

Страница 8: ...and negative terminal signs in the compartment bottom snap four new AA alkaline batteries firmly into the battery holder 4 Replace the battery compartment cover and ensure that the sealing O ring is l...

Страница 9: ...reading accuracy Before beginning a measurement use the sample water to rinse the sample cell at least three times Allow 5 10 seconds for the SP 350P to stabilize Figure 2 For a sample containing 10...

Страница 10: ...zero blank calibration 6 If the calibration succeeds a checkmark and instructions for the slope calibration will appear Figure 4 7 Rinse the sample cell three times with the desired Fluorescent Polym...

Страница 11: ...dule also shown Press Diagnosis or to launch the SYSTEM DIAGNOSIS screen where raw measurement data are displayed Figure 7 The information has no use for normal operation but instead is used for devic...

Страница 12: ...DEVICE INFORMATION screen 3 Press Diagnosis or to launch the SYSTEM DIAGNOSIS screen 4 Allow5 10secondsforthe messagein the top rightcornerof thedisplaychangefrom Starting BTLE to BTLE Started 5 Press...

Страница 13: ...r b The uPyxis Desktop App see the Use with uPyxis Desktop App section 8 3 Factory Reset Use the following steps to restore all device parameters to factory default 1 Power on the SP 350P by pressing...

Страница 14: ...h on your mobile phone Do not pair the phone Bluetooth to the SP 350P Open uPyxis Mobile App Ensure that the SP 350P is discoverable by following the steps in the Bluetooth Connection to Devices secti...

Страница 15: ...en connected the uPyxis Mobile App will default to the Setting screen From the Setting screen the user can set the Power off time and Screen off time in seconds Figure 15 SP 350P User Manual service p...

Страница 16: ...the entire duration of the update Once the update is complete the SP 350P will reboot which will disconnect the SP 350P from the uPyxis Mobile App Figure 16 10 Use with uPyxis Desktop App 10 1 Instal...

Страница 17: ...Pyxis installation 10 2 Connecting to uPyxis Desktop App Ensure that the SP 350P is discoverable by following the steps in the Bluetooth Connection to Devices section Once the app is open to find your...

Страница 18: ...e firmware file contact service pyxis lab com for these firmware files and clicking Upgrade Firmware NOTE The firmware update process takes some time and will require the SP 350P to stay within range...

Страница 19: ...onth The SP 350P will then populate any relevant log event from the selected datalog which can be viewed in more detail by clicking Read Datalog deleted by clicking Delete or exported by clicking Expo...

Страница 20: ...reset the timer and the screen will re light This press will not step along the calibration process the next press needed will still be required in the sequence Always rinse the unit with clean water...

Страница 21: ...he following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to whi...

Отзывы: