background image

Warranty Information

Confidentiality

The information contained in this manual may be confidential and proprietary and is the property of Pyxis
Lab, Inc. Information disclosed herein shall not be used to manufacture, construct, or otherwise reproduce
the goods described. Information disclosed herein shall not be disclosed to others or made public in any
manner without the express written consent of Pyxis Lab, Inc.

Standard Limited Warranty

Pyxis Lab warrants its products for defects in materials and workmanship. Pyxis Lab will, at its option, repair
or replace instrument components that prove to be defective with new or remanufactured components
(i.e., equivalent to new). The warranty set forth is exclusive and no other warranty, whether written or oral,
is expressed or implied.

Warranty Term

The Pyxis warranty term is thirteen (13) months ex-works. In no event shall the standard limited warranty
coverage extend beyond thirteen (13) months from original shipment date.

Warranty Service

Damaged or dysfunctional instruments may be returned to Pyxis for repair or replacement. In some in-
stances, replacement instruments may be available for short duration loan or lease.

Pyxis warrants that any labor services provided shall conform to the reasonable standards of technical com-
petency and performance effective at the time of delivery. All service interventions are to be reviewed and
authorized as correct and complete at the completion of the service by a customer representative, or des-
ignate. Pyxis warrants these services for 30 days after the authorization and will correct any qualifying
deficiency in labor provided that the labor service deficiency is exactly related to the originating event. No
other remedy, other than the provision of labor services, may be applicable.

Repair components (parts and materials), but not consumables, provided during a repair, or purchased
individually, are warranted for 90 days ex-works for materials and workmanship. In no event will the in-
corporation of a warranted repair component into an instrument extend the whole instrument’s warranty
beyond its original term.

Warranty Shipping

A Repair Authorization (RA) Number must be obtained from Pyxis Technical Support before any product can
be returned to the factory. Pyxis will pay freight charges to ship replacement or repaired products to the
customer. The customer shall pay freight charges for returning products to Pyxis. Any product returned to
the factory without an RA number will be returned to the customer. To receive an RMA you can generate a
request on our website at

https://pyxis-lab.com/request-tech-support/

.

Pyxis Technical Support

Contact Pyxis Technical Support at +1 (866) 203-8397,

[email protected]

or by filling out a request for

support at

https://pyxis-lab.com/request-tech-support/

.

ST-590 User Manual

[email protected]

| +1 (866) 203-8397

1

Содержание 50690

Страница 1: ......

Страница 2: ...luorescent Polymer Inline Sensor User Manual January 29 2021 Rev 3 01 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confi...

Страница 3: ...Connecting to uPyxis Mobile App 9 5 3 Calibration Screen and Reading 10 5 4 Diagnosis Screen 11 5 5 Device Info Screen 11 6 Setup and Calibration with uPyxis Desktop App 12 6 1 Install uPyxis Desktop...

Страница 4: ...elivery All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services fo...

Страница 5: ...te interference commonly associated with real world waters The Pyxis ST 590 sensor has a short fluidic channel and can be easily cleaned The fluidic and optical ar rangement of the ST 590 sensor is de...

Страница 6: ...40 F 7 60 C Pressure Up to 100 psi 0 7 MPa Up to 290 psi 2 0 MPa Enclosure Rating IP67 Regulation CE With Pyxis s continuous improvement policy these specifications are subject to change without notic...

Страница 7: ...ssories The following optional accessories can be ordered from Pyxis Customer Service order pyxis lab com or Pyxis E Store at https pyxis lab com shop Figure 1 ST 590 User Manual service pyxis lab com...

Страница 8: ...tall the ST 590 sensor into the ST 001 Tee Assembly follow the steps below 1 Insert the provided O ring into the O ring groove on the tee 2 Insert the ST 590 sensor into the tee 3 Tighten the tee nut...

Страница 9: ...T to 1 4 tubing adapters are used to connect the sensor to the sampling system Sample water entering the sensor must be cooled down to below 104 F 40 C The sensor can be held by a 1 75 inch pipe clamp...

Страница 10: ...ower ground and the negative 4 20mA ter minal on the ST 590 sensor are internally connected Follow the wiring table below to connect the ST 590 sensor to a controller Table 2 Wire Color Designation Re...

Страница 11: ...adapters may result in permanent damage of the ST 590 sensor communication hardware Figure 5 USB connection to ST 590 sensor 5 Setup and Calibration with uPyxis Mobile App 5 1 Download uPyxis Mobile...

Страница 12: ...g steps 1 Open uPyxis Mobile App 2 On uPyxis Mobile App pull down to refresh the list of available Pyxis devices 3 If the connection is successful the ST 590 and its Serial Number SN will be displayed...

Страница 13: ...fault to the Calibration screen From the Calibration screen you can perform calibrations by pressing on Zero Calibration Slope Calibration and 4 20mA Span Follow the screen instructions for each calib...

Страница 14: ...rt Upload This feature may be used for technical support when communicating with service pyxis lab com Figure 9 5 5 Device Info Screen From the Device Info screen You can name the Device or Product as...

Страница 15: ...k 4 5 if not previously installed on the PC the USB driver for the USB Bluetooth adapter MA NEB the USB RS485 adapter MA 485 and the main uPyxis Desktop application Double click the uPyxis Setup exe f...

Страница 16: ...computer 2 Launch uPyxis Desktop App 3 On uPyxis Desktop App click Device Connect via USB Bluetooth or Connect via USB RS485 Fig ure 12 4 If the connection is successful the ST 590 and its Serial Numb...

Страница 17: ...tion description for Device Name Product Name and Modbus Address then click Set to save Figure 13 6 4 Calibration Screen To calibrate the device click on Calibration On the Calibration screen there ar...

Страница 18: ...is screen you can view the Diagnosis Condition of the device This feature may be used for technical support when communicating with service pyxis lab com Figure 15 7 Outputs 7 1 4 20mA Output Setup Th...

Страница 19: ...s Desktop App click 4 20mA Span found on the Calibration Screen shown in Figure 17 Figure 16 Figure 17 7 3 Communication using Modbus RTU The ST 590 sensor is configured as a Modbus slave device In ad...

Страница 20: ...pected and cleaned if required It is suggested that the ST 590 sensor be checked for fouling and cleaned calibrated on a monthly basis Heavily contam inated waters may require more frequent cleanings...

Страница 21: ...90 sensor from direct sunlight and precipitation 9 Troubleshooting If the ST 590 sensor output signal is not stable and fluctuates significantly make an additional ground con nection connect the clear...

Отзывы: