background image

Содержание 1000 ESP

Страница 1: ...1999 Directed Electronics Inc Vista CA N439 12 99 1000 ESP Installation Guide...

Страница 2: ...nsor Harness 4 Pin Connector 23 Internal Programming Jumper 24 Light Flash Jumper 24 Bypassing Sensor Inputs 25 System Features Learn Routine 26 Once a Feature is Programmed 27 To Access Another Featu...

Страница 3: ...transmitters A plug in status LED A plug in Valet Program switch A plug in Stinger shock sensor A Revenger Soft Chirp siren Pre Wired 8618 Starter Kill Relay Primary Harness H1 4 Pin Shock Sensor Plu...

Страница 4: ...anti theft coded radio If equipped with an air bag avoid disconnecting the battery if possible IMPORTANT Many airbag systems will display a diagnostic code through their warning light after they lose...

Страница 5: ...nesses or in the same style loom as the factory When possible place the siren on the same side of the vehicle as the control module where its wires will reach the control module s wires without extend...

Страница 6: ...close to the control module so that the wires do not need to be extended Keep it away from the heater core or any other heat sources and any obvious leaks How the Stinger is mounted is the most import...

Страница 7: ...the Valet Program switch DEI introduced this feature so that switch location was less critical in day to day use As long as the Valet Program switch can be reached to disarm without a transmitter easy...

Страница 8: ...sources for 12V constant the terminal of the battery or the constant supply to the ignition switch Always install a fuse within 12 inches of this connection If the fuse also will be powering other ci...

Страница 9: ...is cold How to find the starter wire with your multimeter 1 Set to DCV or DC voltage 12V or 20V is fine 2 Attach the probe of the meter to chassis ground 3 Probe the wire you suspect of being the star...

Страница 10: ...r kill relay will often be routed together to the ignition switch harness In order to keep the wiring neat and make it harder to find you may wish to wrap these wires together in electrical tape or co...

Страница 11: ...soon as the system is dis armed The orange wire is pre wired to control the 8618 starter kill relay It can supply up to 500 mA of current NOTE If connecting the orange wire to control another module s...

Страница 12: ...he parking light wire If the light flash polarity jumper under the sliding door is moved to the opposite position see Internal Programming Jumpers section of this guide this wire supplies a 200 mA out...

Страница 13: ...is pressed This output can be shut off during the 30 second period by pressing Channel 3 again This output can also be programmed to provide a second unlock pulse when the disarm button is pressed wi...

Страница 14: ...ry This input will respond to a negative input with an instant trigger It is ideal for hood and trunk pins and will report on zone one It can also be used with 506T Glass Breakage Sensor as well as ot...

Страница 15: ...ctor Connect this wire to the 12V ignition wire This wire is pre wired to the starter kill relay and must show 12V with the key in Run position and during cranking Take great care that this wire canno...

Страница 16: ...IMPORTANT Never use this wire to drive anything but a relay or a low current input The transis torized output can only supply 200 mA of current Connecting directly to a solenoid motor or other high cu...

Страница 17: ...If you lose all door lock operation in both directions you are operat ing the master switch in a Type C system If you lose all door lock operation of one or more doors but not all motors stop operati...

Страница 18: ...ystem some other Fords also use Type B The switch will have three wires on it and one wire will test ground all the time One wire will pulse when the switch locks the doors and the other wire will pul...

Страница 19: ...rection only you have located one of the target wires The switch that lost all operation is the master switch If one switch works both directions and the other switch works only one direction you have...

Страница 20: ...This requires mounting the door lock actuator inside the door Other vehicles may only require one actuator installed in the driver s door if all door locks are operated when the driver s lock is used...

Страница 21: ...all the doors lock the vehicle s door lock system can be controlled with just two relays optional The control wire can be found in either kick panel and will show 12V when doors are unlocked and groun...

Страница 22: ...st be wired in series The LED fits into a 9 32 inch mounting hole Be sure to check for clearance prior to drilling the mounting hole The Valet Program switch should be accessible from the driver s sea...

Страница 23: ...conds will trigger the Warn Away response while inputs longer than 0 8 seconds will trigger full alarm sequence and report zone four If installing an optional DEI dual stage sensor connect to the gree...

Страница 24: ...etermine the light flash output In the position the on board relay is enabled and the unit will output 12V on the WHITE wire H1 2 In the position the on board relay is disabled The WHITE wire H1 2 wil...

Страница 25: ...inputs are bypassed for 5 seconds During the 5 second bypass period ground can be supplied to the H1 6 Blue wire without triggering the unit When the 5 second bypass period ends if the unit sees grou...

Страница 26: ...e proceeding 1 Open a door The H1 5 GREEN wire or the H1 7 VIOLET wire must be connected 2 Ignition Turn the ignition on then back off The H1 9 YELLOW wire must be connected 3 Select a menu Press and...

Страница 27: ...ure in the menu you would press and release the Valet Program switch four times and then press it once more and hold it The siren would chirp seven times to confirm access to the seventh feature 1 Pre...

Страница 28: ...trolled domelight off 2 8 Single unlock pulse Double unlock pulse 2 9 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output menu 2 advanced features FEA...

Страница 29: ...lected in step 1 1 then the system can be programmed to either lock the doors when passive arming occurs or only lock the doors when the system is armed via the transmitter Active locking means the sy...

Страница 30: ...tinuous output when the system is triggered This is useful to honk the factory horn in applications where a siren is undesirable Remember that the unit is only capable of supplying 1 amp of current A...

Страница 31: ...ON OFF With the door trigger error chirp programmed off the system will not report an invalid zone on arming when the door trigger wire is active This eliminates the extra chirps that occur when inte...

Страница 32: ...7 must be connected 2 Turn the ignition on The YELLOW wire H1 9 must be connected 3 Select the receiver channel Press and release the Valet Program button the number of times necessary to access the d...

Страница 33: ...and panic channels and a button from that remote is entered into channel one the remote will be erased from memory and the system will only recognize the button that was entered into channel one Chan...

Страница 34: ...rogrammed for standard configuration the transmitter buttons are assigned to the following functions operates Arm only operates Disarm only operates Channel 2 operates Panic and operate Channel 3 The...

Страница 35: ...urth time within five seconds The siren chirps four times followed by a long chirp Zones Two and Four are now bypassed Pressing a fifth time within five seconds The siren chirps five times followed by...

Страница 36: ...e Warn Away triggers are not stored to memory and will not be reported optional vehicle recovery system VRS No additional parts are required to add the optional VRS feature However for the VRS feature...

Страница 37: ...e VRS triggered sequence refer to the Vehicle Recovery System section of the Owner s Guide rapid resume logic The Rapid Resume Logic feature ensures that when the security system is powered back up af...

Страница 38: ...r triggers the system but opening the door does not Have you correctly identified the type of door switch system This happens often when the wrong door input has been used System will not passively ar...

Страница 39: ......

Страница 40: ......

Отзывы: