background image

CONTENTS

1.

INTRODUCTION

5

2.

SAFETY

5

3.

ACCESS LEVELS

5

4.

FEATURES

5

5.

FUNCTIONAL DESCRIPTION

6

5.1

Operating Modes

6

5.2

Entry / Exit Mode

6

6.

ZONES

6

6.1

Engineer Programmable Zones

6

6.2

24 Hour Zones

7

7.

CONTROLS AND FUNCTIONS

7

8.

INSTALLATION AND WIRING

8

8.1

Plan View With Cover Removed

8

8.2

Mounting

9

8.3

Mains Connection

9

8.4

Battery Capacity

9

8.4.1

Battery Charging

9

8.5

Low Voltage Connections

9

8.5.1

Extension  Speakers

9

8.5.2

Wiring The Bell And Strobe (UK Version)

10

8.5.3

Wiring External Sounder / Strobe

10

8.5.4

Remote Keypads

11

8.5.5

End of line resistors

12

8.5.6

Wiring to PIR and other sensors

12

8.5.7

Wiring to a door contact

12

8.5.8

Wiring To A Personal Attack Button

13

8.5.9

Wiring To RKP Remote Zone

13

8.5.10 Wiring the Keyswitch inputs A1 / A2

13

8.5.11 Wiring the communicator outputs / inputs

13

8.5.12 Wiring the latch output (C+)

13

8.5.13 Wiring the LED enable E- / shock reset output

13

8.6

Powering up your panel

13

9.

PROGRAMMING

14

9.1

Factory defaults

14

9.2

User and Engineer Codes

14

9.2.1

Entering and Exiting Engineer Mode

14

9.2.2

Enabling the Limited User

14

9.2.3

Enabling the Cleaner code

14

9.2.4

Changing the Engineer code

14

9.3

Timers

15

9.3.1

Exit time

15

9.3.2

Entry time

15

9.3.3

Bell delay

15

9.3.4

Bell time (External siren)

15

9.3.5

Communicator delay

15

9.3.6

Number of rearms

15

9.3.7

Part set types

15

9.4

Programming Set Modes

16

9.4.1

End of line zones

16

9.4.2

Remote Zones

17

9.5

Miscellaneous Programming Options

17

9.5.1

Tamper alarm

17

9.5.2

Tamper activation

17

9.5.3

Personal Attack (P.A.) Alarm

17

9.5.4

Continued speaker activation

18

9.5.5

User / Engineer reset

18

9.5.6

Timed exit / final set

18

9.5.7

Communicator set / unset Polarity Fault lockout

18

9.5.8

Communicator output Polarity settings

18

9.5.9

Setting the panel when mains fails

18

9.5.10 Setting the Panel With No Battery or Battery Low

18

9.5.11 Keyswitch Options

18

9.5.12 Remote LED Enable / Shock Reset

19

                         RDOC298D/B  Issue 1

3

All manuals and user guides at all-guides.com

Содержание OCTAGON II

Страница 1: ...UCT CANNOT BE OPERATED WITHOUT A REMOTE KEYPAD INSTALLATION INSTRUCTIONS PYRONIX LIMITED MAY 1997 RDOC298D A Issue 1 FOR UK AND EXPORT USE All manuals and user guides at all guides com a l l g u i d e...

Страница 2: ...In the interest of continuing improvement of quality customer care and design Pyronix reserve the right to amend specifications without giving prior notice A copy of our warranty can be obtained from...

Страница 3: ...ck reset output 13 8 6 Powering up your panel 13 9 PROGRAMMING 14 9 1 Factory defaults 14 9 2 User and Engineer Codes 14 9 2 1 Entering and Exiting Engineer Mode 14 9 2 2 Enabling the Limited User 14...

Страница 4: ...10 1 8 Duress Code 22 10 2 Limited User Functions User 2 23 10 2 1 Cleaner functions 23 10 2 2 Deactivating Cleaner zones 23 10 2 3 Omitting zones 23 10 2 4 Changing Limited User code 23 10 3 Master U...

Страница 5: ...current IEE regulations by a technically competent person 3 ACCESS LEVELS Master User user 1 enables Limited User user 2 enables 1 Chime programming 1 Panel setting and unsetting with a unique pass c...

Страница 6: ...o a high tone When all the zones are clear the exit tone will continue again until the end of the time out period and the panel will arm If the exit time is reached before all access and entry exit zo...

Страница 7: ...ich detectors were triggered if an alarm has occurred If there has been an alarm and latch memory was used then when the panel is unset an LED indication will be given at the detectors which were trig...

Страница 8: ...grees of protection required from each zone It is important to decide which type each zone should be if part sets are to be used Work out the cable routes avoiding mains cabling and consider the chose...

Страница 9: ...for 8 hours Pyronix PIRS Typical stand by current for external sounder 50mA 0 05 A e g Self Actuating Bell for 8 hours Typical on state current for external 350mA 0 35 A sounder 20 mins Alarm state cu...

Страница 10: ...ersion PANEL BELLBOX STB Negative Trigger BA Negative Trigger S 12V dc Supply B 0v dc Supply BT Bell Tamper negative return 8 5 3 Wiring the External Siren Export Version Wiring the Strobe 10 All manu...

Страница 11: ...8 5 4 Remote Keypads Remote Keypads Continue RDOC298D F Issue 1 11 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 12: ...uld be ignored Any unused zones should NOT be left open circuit These should have a 2K2 resistor inserted 8 5 6 Wiring to PIRs and other Sensors Wiring to one sensor Wiring to two or more sensors TT N...

Страница 13: ...tch output C The latch C output is used to disable a detectors LED When the panel is armed the latch sets positive 12v disabling the LED When the panel is unset the latch line toggles resetting the de...

Страница 14: ...2 1 Entering and exiting the Engineer mode With the control panel in day mode enter the Engineer code A will be displayed on the remote keypad s when the Octagon II is in Engineer Mode Any covers may...

Страница 15: ...fter an activation until the communicator delay has expired Whilst in Engineer mode enter followed by a 2 digit time in seconds The communicator delay may be programmed as any 2 digit number from to 9...

Страница 16: ...eturn the control panel to engineer mode Repeat the above sequence to change any other zones Example 1 To reprogram zone 5 in part set B from immediate to access Enter Engineer Mode Press zone code fo...

Страница 17: ...mode will normally only activate the extension speakers It is possible to program the Octagon II to also activate the external sirens when a tamper alarm is generated in day mode This is done as follo...

Страница 18: ...at the keypad and this tone will end when the zone is closed The system will then set 9 5 7 Communicator Set Unset Polarity The Communicator set unset output can be programmed to operate as switched p...

Страница 19: ...removed Finally reconnect the battery negative terminal 9 8 Programme Mode Test Facilities 9 8 1 Walk Test A walk test of the Octagon II control panel will give an audible and visual indication of zo...

Страница 20: ...urn to Engineer mode when all recorded events have been displayed 1 Indicates that the next event caused the alarm activation when the panel was in day mode RKP II LED display layout RKP display layou...

Страница 21: ...A number and the tamper LED indicates a tamper zone activation e g zone 7 12 The tamper LED indicates a bell or case tamper 13 Indicates an entry exit activation of the remote keypad zones 14 followe...

Страница 22: ...me two tone chime to be given by the remote keypads and speakers The chime zone number will also be displayed on the RKP A chime caused by a RKP remote zone will be displayed as To turn off the chime...

Страница 23: ...e these by displaying the zone number s selected Now enter to allow the exit period to continue 10 2 4 Changing Limited User Code In day mode enter followed by the existing Limited user code The keypa...

Страница 24: ...zones may be programmed to chime In addition to this when the system is part set any omitted zones can also be programmed to chime This allows the chime to operate at any time except when the control...

Страница 25: ...r or To part set the panel To return to day mode enter Engineer code 11 LED FUNCTIONS Panel PCB Supply LED on Indicates a mains supply Remote Keypad Supply LED on Indicates a mains and or battery supp...

Страница 26: ...load 8 to 32 Ohms Bell 500mA Strobe 500mA Alarm bell timer 0 to 20 minutes software programmable Zone type Normally closed loops which activate when opened or short circuit Zone loop current 0 76 to 1...

Страница 27: ...ay mode or Engineer mode If this does not work press then wait again 1 Panel unset Day Mode RKP II LED display layout RKP LED display layout During Exit Mode the following four symbols are displayed f...

Страница 28: ...panel the tamper LED flashes and the tamper tone is emitted there is For the following conditions the violation indicated will cause a continuous tone to be heard Enter a user code once to display the...

Страница 29: ...e activated 21 Fire alarm The LED display shows the number of the zone activated 22 Engineer code is required to reset the panel The LED shows the number of the zone activated 14 SYSTEM STATUS RDOC298...

Страница 30: ...15 LIMITED USER QUICK REFERENCE GUIDE 30 All manuals and user guides at all guides com...

Страница 31: ...16 ENGINEER QUICK REFERENCE GUIDE 17 ZONE PROGRAMMING LABEL 18 OCTAGON II SERVICE HISTORY RDOC298D P Issue 1 31 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 32: ...32 All manuals and user guides at all guides com...

Страница 33: ...RDOC298D Q Issue 1 33 All manuals and user guides at all guides com...