KX15DT
15m Dual-Technology Detector
0845 6434 999 (UK). +44(0)1709 535 225
www.pyronix.com
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
RINS549-14
EOL
The KX15DD Printed Circuit Board
®
D
C3
PCB
EN50131-2-2:2008
EN50131-1:2006+A1:2009
PD6662:2010
Security Grade (SG) 2
Environmental Class (EC) II
Lens
Illuminator
Lens
Lens
Holder
PCB
Screw
PCB
START
f) Back
Tamper
1
2
C
D
3
A
LED ON
LED OFF
4
6
P
IR
TAMPER
A
B
B
C
A
Casing Screw
Nut
H
F
B
G
D
C
E
AND
DO NOT USE ‘OR’ MODE
WITH THIS PET IMMUNE
DETECTOR
5
A
Conventional Dual Tech (Both
technologies need to be triggered
simultaneously to generate an alarm)
OR
7
Minimum
Range (0m)
Maximum
Range (10m)
Not
Recommended
Note: turning the pot fully anti-clockwise
turns off the microwave
8
= 50Hz
= 60Hz
(Default)
E N G L I S H
(Diagram references)
Technical Specification
Warranty & Compliance
Contact Information
This product is sold subject to our standard warranty conditions and is warranted against defects
in workmanship for a period of five years. For further warranty information visit:
www.pyronix.com/warranty
The declaration of conformity and further compliance documentation may be consulted at:
www.pyronix.com/product-compliance.php
For electrical products sold within the European Community. At the end of the electrical products
life, it should not be disposed of with household waste. Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling advice in your country. This product is
approved for use in the Residential, Commercial and Light Industrial Environments.
Secure Holdings, Pyronix Ltd,
Website: www.pyronix.com
Braithwell Way, Hellaby,
Rotherham,
South
Yorkshire
S66
8QY
UK
Model:
KX15DT
Colour:
White
LED Colours:
Orange (Microwave), Blue (Alarm), Green (PIR)
Casing:
3mm ABS, 0.4mm HDPE in lens area
Detection Method:
Low noise dual element pyroelectric sensor & Microwave doppler sensor
PIR Sensitivity:
Auto (Default), High
Temperature Compensation:
Digital
Detection Range:
15m (13m by EN50131-2-2 & INCERT criteria)
Detection Speed:
0.3 - 3.0 m/s
Operating Voltage:
9 - 16V DC 13.8V DC typical
Current Consumption:
24mA @ 12V (Min), 30mA @12V (Max)
Relay Output:
50mA 60V DC, 42 VAC (RMS)
Contact Resistance:
< 10 ohms
Mounting Height:
1.8 - 2.4m
Tamper Switch:
12V 50mA
Temperature:
-40
o
C to 80
o
C (storage)
-10
o
C to 40
o
C (certified) -30
o
C to 70
o
C (nominal)
Accessories:
Wall and Ceiling brackets
Emissions:
EN55022 Class B
Immunity:
EN50130-4
1
2
33
The Printed Circuit Board (PCB)
Terminals
Mains Frequency
Disassembling the KX
Cable Entry / Mounting
Sensitivity Settings:
Auto Sensitivity (Default) High Sensitivity
34
Bracket Mounting Options
The 15m Volumetric Lens. Dimensions and Weight
Note:
In an EN50131-1 (and INCERT) system the
maximum detection is 13m.
EOL Resistor Headers:
The KX15DQ has 2 sets of header pins (as shown). These headers
are used to select the End of Line resistance for EOL wiring applications.
NOTE: If EOL wiring is not used, leave the headers OFF.
Powering Up:
When the detector is first powered up, it will run through a self-test
routine (indicated by the flashing blue LED). Once the LED goes out the detector
is ready to use.
35
3
10
3
3
3
A
B
C
D
E
36
A
B
AND/OR Mode: “AND”
-
Conventional Dual-Tech (both technologies need to be
triggered simulataneously to generate an alarm)
“OR” -
If either single technology detects an intruder activity an alarm will be generated.
3737
Microwave Potentiometer:
-
Minimum Range (0m), Maximum Range (15m)
Note:
Turning the pot fully anti-clockwise turns off the microwave.
3738
3739
N/C
- Normally Closed Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
S
ingle End of Line Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
DEOL Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
2x Double End of Line Detectors to One Input
(SEE CONTROL PANEL INSTRUCTIONS)
Zone Doubling Example
A
B
C
D
E
F
G
H
Sensitivity (Auto/High) - see section.6
‘AND/OR’ Mode- see section.7
Alarm LED
Resistor Headers (Tamper / Alarm)
Pyro Sensor (DO NOT TOUCH)
Microwave Potentiometer (adjust)
Installation Hints:
Do not partially or completely obscure the detector’s field of view with
large objects such as furniture.
Avoiding False Alarms:
When the detector is first powered up, it will run through a
self-test routine, indicated by the flashing LEDs. Once this has extinguished - the detector
is ready to use.
1:
Avoid Placing the detector in direct sunlight.
2:
Do not let pets and other animals
wander freely whilst the alarm system is armed.
3:
Do not mount the detector near heaters or radiators.
4:
Do not mount the detector near open windows or air vents.
11
12
13