SWITCH
FEATURE POSITION
MEANING
ON
LED Enable
A
LED Enable
OFF
LED Disable
ON
Periodic self test
B
Self Test mode
OFF Remote self test
C
Relay mode
ON
Relay normally closed
OFF Relay normally open
D
Digital signal
ON
SPP+
Processing
OFF
SPP+1
OFF
PC 1
ON
PC 2
E
Digital signal
ON
SPP+
Processing
ON
SPP+1
OFF
PC 1
OFF
PC 2
F
Walk test mode
ON Walk test LEDs disable
OFF Walk test LEDs enable
INSTALLATION
1
. Remove case lid by unscrewing fixings screw as illustrated in
and unclip the PCB, taking care not to touch the Pyro sensor
labeled .
2
. Choose wall fixing holes, labeled and on diagram.
3
. Mark wall for fixing positions (Do not route wires near mains cabling,
avoid vibrating surfaces and mount only on a solid wall).
4
. Drill fixing holes.
5
. Fix case to wall.
6
. Replace PCB again taking care not to touch the pyro sensor (labeled
on diagram).
7
. Select and fit the appropriate lens for your application (See diagram ).
8.
Using dip switches (See diagram ) select required features and modes of
operation.
9.
Carry out walk test.
10.
Re fit detector front cover using fixing provided (See diagram ).
POTENTIAL FALSE ALARM HAZARDS.
1
. Direct sunlight on detector may cause false alarms.
2
. Pets and animals may cause false alarms.
3
. Mounting detector near heaters may cause false alarms.
4
. Draughts from open windows may cause false alarms.
DIAGRAMS
Coverage Patterns
Dimensions and weight
Board layout
Pyro sensor
DIP Switches
Mounting and cable entry knockouts
Cable entry knockouts
Wall fixing knockouts
Wall fixing knockouts
Detection methods
Detailed connections
Control panel connections
Tamper operation
Alarm relay operation (N/C)
Alarm relay operation (N/O)
Removal and replacement of front cover and lenses
Front cover fixing screw
Removing and replacing the lens
Optional rear tamper.
GB
C1
C
G2
G1
C2
G1
C1
D2
D3
B
A
G
C
C1
C2
C3
D1
D
D2
D3
E
F
F1
F2
F3
F4
G1
G2
H1 H2 H3
Power up Normal alarm Normal alarm
walk test selected
H4 Latch
Center LED flashes at intervals of 1-2 seconds
H5 Fail self test
Center and outside LEDs flash alternately
WARRANTY
This product is sold subject to our standard warranty conditions and is warranted against
defects in workmanship for a period of five years. In the interest of continuing improvement
of quality, customer care and design, Pyronix Ltd reserve the right to amend specifications
without giving prior notice
DIP switches (see diagram )
Note: As Factory Default all switches are ON
1
1
1A
1A
1B
1B
1C
1C
2
2
3
3
3A
3A
3B
3B
4
4
5
5
6
6
7
7
OPERATION OF FEATURES
1. LED Enable / Disable (Switch A)
ON = LED Enable
OFF = LED Disable
2. Self Test (Switch B)
ON = Periodic self test mode
OFF = Remote self test mode
2.1 Periodic Test
In periodic test mode, a self test is commenced after 5 hours of PIR
inactivity. If the test passes there is a short delay before the detector
settles and resumes to normal operation.
2.2 Remote Test
The remote test will only be activated if the RT terminal is connected to
the control panel. If the RT connection goes high then the detector
immediately performs a self test. If the test passes then the detector
immediately performs a self test, if the test passes then the relay changes
state for 3 seconds.
2.3 Failure of a test
(See diagram )
If the test fails the LEDs flash alternately (See diagram )
If a valid alarm activation is processed then the detector will return to its
normal operation. In the unlikely event of a continuous test failure then
please contact Pyronix technical support.
3. Relay modes (Switch C)
ON = Relay is in normally closed mode. (N/C)
OFF = Relay is in normally open mode. (N/O)
4. Digital signal processing settings (Switch D & E)
PC 1 =
One detection zone must be crossed.
SPP+ =
Two opposing detection zones must be crossed.
PC 2 =
Two detection zones must be crossed.
SPP+1 =
Two opposing detection zones and any other zone must be
crossed.
5. Walk test LED enable (Switch F)
ON = Walk test LEDs are disabled.
OFF = Walk test LEDs are enabled.
5.1
When the walk test LEDs are enabled three LEDs will illuminate in a
normal alarm activation. See diagram
5.2
When the walk test LEDs are disabled the middle LED will illuminate
in a normal alarm activation. See diagram
5.3
The walk test LEDs will be automatically disabled after 10 minutes to
reduce power consumption.
6. C+ Latch terminal
This function allows an activated PIR to be identified after an alarm
condition by a flashing LED, see diagram
6.1 Connection
Connect (C+) to a PGM at the control panel programmed to be 12V after
arming. To reset the latch memory, create a 5 second switch from OV to
12V and back to 0V.
6.2 Pyronix Panels
Connect detector input C+ to a PGM output configured as C+ using a
2K2 resistor from AUX+ to the PGM output.
To reset the latch memory enter the user code twice within 5 seconds.
7. RT Remote self test terminal
If remote self test is selected (switch B off), a self test can be initiated by a
momentary switched 0 volt input. Refer to section 8.1 and 8.2
8. E- Remote LED enable terminal
To use the remote LED enable feature switch A must be in the OFF
position.
8.1 Connections
To remotely enable LEDs, 0 volts must be applied to the E- terminal.
8.2 Pyronix Panels
Connect detector input E- to a PGM output and configure as walk test.
OPTIONAL TAMPER UNIT
Note: The Kudos detector may be fitted with an optional back tamper, which is sold separately.
SPECIFICATIONS (QUICK REFERENCE)
Model:
Kud
o
s
Casing: White3mm ABS Back / Front cover
White 3mm HDPE lens cover, 0.7mm in faceted area
Lens: Volumetric: 20m, 74 zones, 7 planes, 2.4m mounting height
Curtain: 25m, 24 zones, 6 planes, 2.4m & 5m mounting height
Long range: 45m, 46 zones, 6 planes 2.4m mounting height
.
Detection method: Low noise dual element pyroelectric sensor
Digital signal processing:SPP+ , SPP+1, PC 1, PC 2.
Detection speed: 0.3 - 3.0 m/s
Operating Voltage: 9-16 VDC
Current consumption: 22mA Quiescent
@13.8V 48mA Walk test mode
105mA self test (short burst per test)
Relay Output: 60Vdc, 50mA (42.4Vac peak)
Mounting Height: 1.8 - 2.4m
Tamper Switch: Normally closed voltage free contacts
(12V 50mA max rating)
0
0
0
0
Storage Temp: -40 C / 80 C (-40 F / 176 F )
0 0
0
0
Operating Temp: -30 C / 70 C (22 F / 158 F )
Emissions: EN55022 Class B
Immunity: To new European Standard EN50130-4
Accessories: Optional back tamper
C
Installation
Mounting with back tamper
Flat against a wall
Corner mounted
45 Degree o all
n w
Cut out the tamper position
required, using scalpel or sharp
utility kni e
f
Orientation of tamper unit
Left hand side
Right hand s de
i
Ensure tamper switch lever
is orrectly orientated
c
osition switch and tamper plate.
P
Position unit within detector,
using step three, for orientati n
o
of unit.
Ensure clip fixtures are located
in the correct p sition, on the
o
outer surfac f the casing.
e o
H5
H3
H2
RINS 411-7
H5
H4
Kudos
Including 3 Lens Variants
0C03
PYRONIX LTD
R
This product is approved for use in the
Residential, Commercial and Light Industrial Environment.
Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND
Technical help line (UK only): 0870 122 3360
This is a national rate line
www.pyronix.com
This product complies with TS50131-2-2. at security grade 2,
environmental class 2.
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1