Pyronix Kudos Скачать руководство пользователя страница 2

T T

T T

F2

NORMAL

TAMPER  ALARM

0

.8

m

 

1

.3

m

 

1

.4

m

 

2

.3

m

 

2

.4

m

 

3

.8

m

 

6

.0

m

 

6

.6

m

 

1

0

.5

m

 

1

1

.0

M

 

1

7

.0

m

 

4

5

.0

m

 

VERTICAL COVERAGE 

2.4m

              2m         3m        4m         5m        6m        7m         8m        9m                    11m       12m      13m      14m       15m      16m      17m       18m      19m       20m     21m       22m       23m      24m      

1m 

10m 

25m 

HORIZONTAL COVERAGE AT MAXIMUM RANGE

0

.8

 m

1

.1

m

1

.6

m

2

.0

m

2

.6

m

3

.4

m

4

.4

m

5

.8

m

7

.7

m

1

1

.0

m

VERTICAL COVERAGE 

REMOVING AND REPLACEMENT OF FRONT COVER AND LENSES.

G

G1

G2

REMOVING THE  LENS:

With the front cover removed, 
unclip the lens as shown above.

 

NOTE:

When removing the 
front cover leave the 
screw in place

 

REPLACING THE LENS:

Locate the lens by hooking onto the three bottom pegs 
and push the lens into position, ensuring that the lens 
is secure via the side and top clips.  

F3

F4

NORMAL

NORMALLY CLOSED OPERATION

NORMALLY OPEN OPERATION

NORMAL

ALARM

ALARM

N

N

O

O

B

Kg

79.2 g  

65mm

55mm

155mm

DIMENSIONS AND WEIGHT

D

D1

D2

D3

NOTE:

D2 and D3 have 
been designed to 
allow the detector 
to be mounted in
a corner, 
45 degrees to 
a wall or flat 
against a wall.  
 

MOUNTING AND 
CABLE ENTRY KNOCKOUTS

F

TAMP

PGM  

C+

PGM

RT

PGM

WALK TEST

12V
50mA

Remote 

LED

enable

Remote 

test

Latch

60V
50mA

9 - 16Vdc
22mA
@12Vdc

ZONE

C+ RT E-

WIRING TO CONTROL PANEL

F1

25m CURTAIN LENS

HORIZONTAL COVERAGE AT MINIMUM RANGE

A2

O

20
24 zone edges
6 planes

C1

C3

C3

C2

C

A

+

-

N

C

T

T

C+ RT E-

B

C

D

E
F

0

1

2

3

4

5

6

7

8

9

1

0

A = LED Enable

B = Self Test

C = Relay Mode

D = PIR mode 1 

E = PIR mode 2

F = Walk Test

On           Off

Dip Switches

Optional

rear tamper

Front Tamper

LEDs

ON

 =   Normal, link fitted

OFF

 = Optional, rear tamper 

            spring fitted

BOARD LAYOUT

PYRO 
SENSOR

E

             

PIR DETECTION METHODS

 

PC 1     = 

One detection zone must be crossed.   

SPP+    = 

Two opposing detection zones must be crossed.   

PC 2     = 

Two detection zones must be crossed.   

SPP+1  = 

Two opposing detection zones and any other zone must be crossed.

                                                                                 

0.3 - 3.0 m/s

1      2       3

SPP+

PC 1

SPP+1

PC 2

Switch

                           D               E
PC 1

                 OFF       OFF

SPP+                

ON 

      ON

PC 2                 

ON 

     OFF

SPP+1              

OFF          ON

C2

2m

1m

1m

2m

2m

1m

1m

2m

2.4m 

5m 

3m 

0m 

0m 

3m 

3m 

3m 

HORIZONTAL COVERAGE

20m VOLUMETRIC LENS

A

A1

COVERAGE PATTERN AND PLAN VIEW

        2m         3m        4m         5m        6m        7m         8m        9m                    11m       12m      13m      14m       15m      16m      17m       18m      19m       

19m

18m

17m

16m

15m

14m

13m

12m

11m

9m

8m

7m

6M

5m

4m

3m

2m

1m

1m

10m

20m

10m

20m

O

90
74 zone edges
7 planes

2

.9

1

 m

 

4

.6

8

 m

 

6

.0

4

 m

 

0

.7

0

 m

1

.9

3

 m

 

1

.2

6

 m

2.4m

 

VERTICAL COVERAGE 

1

1

.8

 m

 

45m LONG RANGE LENS

A3

HORIZONTAL COVERAGE

              2m         3m        4m         5m        6m        7m         8m         9m                    11m       12m      13m      14m       15m      16m       17m        18m       19m                    21m      22m       23m       24m      25m      26m       27m      28m      29m                  31m      32m       33m      34m      35m      36m       37m      38m      39m       40m      41m      42m       43m      44m       

17m

16m

15m

14m

13m

12m

11m

10m

9m

8m

7m

6m

5m

4m

3m

2m

1m

1m

2m

3m

4m

5m

6m

7m

8m

9m

10m

11m

12m

13m

14m

15m

16m

17m

18m

0m

18m

1m

10m

20m

30m

45m

O

90
46 zone edges
6 planes