Page: 29
Program LAN?
Auto Set Up?
Yes: The Control Panel will obtain the setup data from the router using DHCP.
No: The following will be required:
o
IP Address: Enter the IP Address where xxx is a number between 1 & 255.
o
Subnet Mask: For most domestic installations the subnet mask will be 255.255.255.0.
o
Gateway: Enter the gateway, which is the routing device that the panel is connected
to.
o
1
st
DNS IP Address: Enter the DNS Server IP Address.
o
2
nd
DNS IP Address: Enter the alternative DNS server IP address if required.
Program Wi-Fi:
Setup with WiFi Device?
Simply press YES and you will be taken to a screen displaying the SSID and password – you will
then need to connect to the Control Panel from a smart device or PC to continue the WiFi setup.
Please see the Programming manual (RINS1841-1) or the WiFi module instructions.
SSID?:
- Enter the Panel’s SSID manually in this menu.
Password?:
- Enter the Panel’s WiFi password manually in this menu.
5.17.3
Program signalling
The Control Panel can communicate with an Alarm Receiving Centre (ARC) using the LAN module
or the GPRS modem.
ARC Details: Choose which ARC to program from 1 to 4.
Formats Available:
Contact ID IP = See
page: 43
for the event table.
Fast Format IP = See
page: 43
for default values.
SIA IP = See
page: 43
for the event table.
Valid Areas:
This option permits the set up of a different ARC for a different area. Select which area this
particular ARC will be reporting. Selecting 01ABCD means the ARC will be receiving events from all
areas.
Area Accounts?
This options permits the engineer to set up an individual area account for each area or open
common account for all of them. Use the
a
key to add hexadecimal values; B to F. Numbers are
entered using the number keys.
Redials: If the alarm event has not been received by the monitoring station after the first number
has been called, the second number will be called. The two numbers will be alternated as many
times as the redials are set to. If a call has been acknowledged by the monitoring station then the
Control Panel will stop calling.
Timeout:
This is the time of how long it takes a call to timeout before it is not answered.
Low Battery Report: Enables or disables low battery reporting.
Test Calls:
The test call is used to show that the system is still active when no activations have been made.
Setting up a test call asks for a start time in hours and minutes and the frequency of the call in
days, hours and minutes.
Event Types: Please see page: 43 for all event options. If ‘Custom’ is selected, all event types can
be chosen.
Sign Up to ARC?:
ARC Code/ IP Address: Enter the ARC code supplied by your provider – for easy setup.
Alternatively you can manually enter the IP Address that is supplied by the ARC (use the
a
key to
enter ‘.’ (full stops/dots))
ARC Port Number: The Port of the ENIP Server that is supplied by the ARC.
Security Level:
Normal: Requires a password and connection handle (supplied by the ARC).
High: Send Key by SMS (THIRD PARTY SIM CARDS ONLY):