Страница 2: ...ng to InSite Software 35 8 Options Programmable Only From PC 38 8 1 Auto Set Unset Timers 38 8 2 Areas to Set Unset 38 8 3 Programming Logic Gates 39 9 Faults and Troubleshooting 40 9 1 Device Fail Ac...
Страница 3: ...Page 3 2 2 PyronixCloud and HomeControl App...
Страница 4: ...ngineer menu the panel must be in an unset state While in Engineer mode all tamper alarms including case tamper will be disabled 4 1 Navigating in the Engineer and User Menus NO Press to move forward...
Страница 5: ...d on the system until the Engineer or User menu has been exited 5 Engineer Menu Please refer to the Engineer Programming Manual for this chapter The meaning of every option presented in the quick prog...
Страница 6: ...and a confirmation tone will be emitted by the panel 6 If an input has already been learnt Input learnt already will be displayed Example The image below shows how to learn an MC detector Please note...
Страница 7: ...played while the Panel deletes the wireless bell Return to this process to delete more devices 5 3 5 Control Arming Stations Learn Devices Entering this menu allows the learning of wireless Arming Sta...
Страница 8: ...User Keyfobs 1 Enter Master Manager menu Press the Key then enter code Default Master Code 2222 2 Scroll to the function CHANGE CODES 3 Choose the keyfob to delete Between the brackets will show 4 Pr...
Страница 9: ...a set B C D acts as Entry route input as above 11 PTS Active during exit time to complete Setting procedure No audible or communicator response Note May be used to act as doorbell by use of chime attr...
Страница 10: ...tivated 43 Final Exit 2 This is useful if you would like to set different times for the front door and the back door of a house for example See Final exit listed above for more details Input Areas Ent...
Страница 11: ...input 2 This label will show the event log and following alarms reported in the SMS alarms as a reference point Enter Location This is commonly used to write the location of the input such as Input N...
Страница 12: ...r on the display if a fault occurs Press to return to ZEM addressing 5 Press to return to the Engineers menu NOTE If adding wired input expander ZEMs we recommend using the version with the PSU integr...
Страница 13: ...rt When the system is silenced after an intruder alarm has been activated After two minutes 0006 Confirmed Any After two intruder alarm activations At the next code entry 0007 Tamper Any Tamper alarm...
Страница 14: ...h an active detector attempting to unshunt the Shunt Fault output pulses until the shunt is reset 0037 Restore 1 At code entry to set The normal state of this input is 0v and it changes to 12v when ac...
Страница 15: ...nce the programmed NAT time has elapsed It will be cleared restored by the next valid code entry 0066 ATE Not Used Makes the ATE pin 5V or 0V depending on whether ATE outputs are inverted 0170 0199 Us...
Страница 16: ...Select this type if the reader is to be used as an unset device only 4 Entry Control Used to lock unlock doors The external or internal reader can have magnetic locks connected to them This option is...
Страница 17: ...splayed Enter the name of the keypad and press 10 Enter Location will be displayed Enter the location of the keypad and press 11 Press or to select another device address to program 0 7 or press the k...
Страница 18: ...or press the key to return to the Engineer menu Programming Wireless Arming Stations Assign Keypads Readers 1 Press or to scroll to ASSIGN KEYPADS READERS Press 2 Press or to select from addresses 6...
Страница 19: ...0 9 or press the key to return to the Engineer menu 5 9 Change Timers Timers Description Options Entry Time Programmes the entry time for each area Ensure that the timer is no longer than 45 seconds i...
Страница 20: ...omms Fault alarm is triggered NOTE In the case of devices connected via the ATE pins this time is additional to that already applied by the ATE 0 250 minutes Set Fail The time after which the Set Fail...
Страница 21: ...mber 1 that is programmed see SET UP DOWNLOADING on page 34 will be dialled 5 10 4 Change Master Manager Code The Master Manager code can be 4 5 or 6 digits long or can be assigned to a tag It may als...
Страница 22: ...6 7 Main Sounder 5 11 7 Day Alarm Volume 0 Completely Silent 1 Silent but beeps when the system is set 2 5 keypad 6 7 Main Sounder 5 11 8 Chime Volume 0 Completely Silent 1 Silent but beeps when the s...
Страница 23: ...ly available after the system is set Exit Starts Confirmed signal available after the exit time has started NOTE Not compliant with DD243 NOTE Exit Starts must be selected in order for it to be entere...
Страница 24: ...xt The text that is displayed when all areas are set Sign On Message Eg Euro 46 App Display When Set If Yes the keypad display will show set once the panel is set NOTE This must be programmed as No to...
Страница 25: ...leted will be displayed When walk testing a double knock detector it must be triggered twice within the preset period When testing dual trip detectors you must first open detector one and then trigger...
Страница 26: ...ngth as a percentage 3 Excellent signal Shows GREEN on the wireless Device 80 to 100 2 Good signal Shows GREEN on the wireless Device between 30 to 80 1 Weak signal Shows RED on the wireless Device be...
Страница 27: ...ule GPRS Signal Strength The range 0 31 indicates the signal 31 Excellent 15 Poor indicates no signal App or ARC Status messages Displays the current connection status of the PyronixCloud Initialising...
Страница 28: ...m the Apple store Please refer to the User Manual and APP Guide for setup details Use App If set as YES this enables the App functionality System ID Displays the unique control panel System ID require...
Страница 29: ...a this particular ARC will be reporting Selecting 01ABCD means the ARC will be receiving events from all areas Area Accounts This options permits the engineer to set up an individual area account for...
Страница 30: ...edials If the alarm event has not been received by the monitoring station after the first number has been called the second number will be called The two numbers will be alternated as many times as th...
Страница 31: ...123456 Set A Omit Kitchen 123456 User Code Set A Omit Kitchen Sets area A and will omit the input that is called Kitchen Input omit area A Kitchen 04 Forced Set area A Omitting inputs via SMS text com...
Страница 32: ...arage Door status check OUTPUT Garage Door ON or OUTPUT Garage Door OFF NOTE The name of the output has to be one word and spelled exactly as written in the panel such as Garage Door is not acceptable...
Страница 33: ...ion should be set to YES to disable confirmation once the entry procedure has started For use with BS8243 option 6 4 5 this option should be NO If Disable Confirm On Entry is set to YES this option wi...
Страница 34: ...s installed on See section 7 on page 35 for further instruction on different connection methods 5 20 Software Revision This option shows the software version hub version and Comms module version insta...
Страница 35: ...to the normal display 7 Connecting to InSite Software The Control Panel can be programmed by the LCD menu or the UDL InSite Software provided free of charge It can be downloaded from http www pyronix...
Страница 36: ...field 17 Enter the Engineer code as used on the Control Panel you are trying to connect to 18 Enter the Site Name as entered in the panel ONLY if it was entered on the panel to otherwise leave this bl...
Страница 37: ...ftware or leave blank then Press 6 Finally go out of this menu and then into the Site Options main menu and then scroll through until Cloud Priority set this to Normal for initial connections and then...
Страница 38: ...the screen under Date 3 If any holidays are added by mistake select that holiday and click delete NOTE Make sure that any action already programmed matches correctly when the holiday period has finis...
Страница 39: ...AND when area C is also set This could be useful in a scenario where different offices are occupied in different areas and do not require an external communicator or siren to signal an alarm in one ar...
Страница 40: ...the ARC has failed NOTE This is a communication problem which is rarely caused by an equipment fault Primarily this is related to the hand shake and kiss off frequency set up at the receiver Check th...
Страница 41: ...pply failed The system detects that the mains frequency is out of specification as well as voltage Note AC FAIL timer operative LOW VOLTS xxx Power supply volts low Battery volts below normal battery...
Страница 42: ...ces Input xx Wirles Poll Fail Wireless Poll Fail displays when no polls wireless comms are received for 20 minutes before the set operation Test signal strength battery status for each wireless device...
Страница 43: ...ES YES YES Comms Status YES NO NO NO YES Technical Fault YES NO YES YES YES Abort YES NO NO NO YES Information YES NO NO NO YES Access Alarm YES NO NO NO YES Access Event YES NO NO NO YES Omit Restore...
Страница 44: ...up 00 Enter Name Input 0 Enter Location _ CHOOSE MODE EOL Range 4K7 2K2 1 EOL Mode DR 1 Input Response 300ms 03 INSTALL ZEMS ZEM Address 0 ZEM Installed No 0 CHANGE OUTPUTS Endstation Outputs BELL O P...
Страница 45: ...es Confirm Time 30 minutes HU Confirm Time 08 hours Strobe Time 00 minutes Re Arm No 3 AC Signal Delay 040 minutes Settle 005 seconds Double Knock 10 seconds Pre Alarm 030 seconds Comms Fault Delay 03...
Страница 46: ...3 Tag Opens Doors No 0 Set With Poll Fail No 0 Fob Unset Entry Yes 1 Wireless Bell Supervision Yes 1 Download If Set No 0 Cloud Priority Low 1 System Displays Area A B C D 0 1 Text Area Full Area Tex...
Страница 47: ...BCD Area Accounts No 0 ARC Account _ Redials 03 Time Out 30 Test Calls No 0 Event Types Default 0 Sign Up To ARC Program Digi Channels Digi 01 Fire 0001 Digi 02 HU Device Any 0009 Digi 03 Unconfirmed...
Страница 48: ...ps Sirens Only 2 Start at Stop at Digi 3 If area set SET UP DOWNLOADING Download by None 0 Security Level Normal 0 Always Poll Cloud No 0 Roving Dial No 0 13 Event Types SIA and Contact ID codes Event...
Страница 49: ...RESTORE Fire Alarm Restore FH 3110 11 on on Fire key Restore FH 3110 11 HU ALARM Duress Code HA 1121 12 on on on on Keypad PA PA 1120 12 Radio fob PA PA 1120 12 HU Alarm PA 1120 12 Silent HU HA 1122...
Страница 50: ...1 Battery Critical YT 1302 21 Wired Siren Fault YA 1320 21 TECHNICAL RESTORE Battery Connect YR 3311 22 on on Device Restored ER 3333 22 Fuse fail restore IR 3300 22 Detector Fault Restore BJ 3324 22...
Страница 51: ...28 Zone Special Log Switcher Closed UR 3146 28 ALARM SILENCED Alarm Silenced OR 1406 29 on Sub Area Alarm Silenced OG 1402 29 TECHNICAL ALARM SILENCED Technical Alarm Silenced OR 1406 30 Technical Al...