EURO 162/280 Installation Manual
Page: 57
2. Verify that COM port associated to “Modem” in the UDL is the same set in the PC
3. Verify that the modem Icon is green and glowing in the software Graphic User Interface
4. In the “Configurations” menu choose the “Modem Type” from the drop down menu. This is the
modem connected to the PC and used to call the panel
5. Press “Load Default String” to program the right initialization string for the selected modem
6. Click on “Force Dial customer”
7. Set “Dial Mode” field to “MODEM”
8. Insert the telephone number in “Telephone Number” field
9. Enter the Engineer code in the “Engineer Code” field
10. Click on “Dial”
11. If connection is successful, the modem Icon will become blue.
NOTE:
If a Site Name is set up on the panel the UDL Site Name must be the same otherwise the
connection will not be possible.
T
he PSTN modem card (EURO-073-ARM) fits inside the EURO control panel and is used for the
following operations:
Send Alarms to the ARC: It is possible to send alarm events to the monitoring station via Fast
Format.
Programming the panel remotely via the telephone line:
It is possible to program the EURO
control panel remotely via the telephone line. In order to be able to use this feature it is
necessary that the telephone line used is analogue conventional telephone line.
Receive Automatic Remote Service calls and alarms:
It is possible to receive the remote
maintenance service and alarm calls received by the UDL software installed on a PC and modem.
10.2.4
Certification
This product complies with all requirements of the European ‘R&TTE Directive’
1999/5/EC for connection to the PSTN. It is approved for use throughout the EU,
see ‘Declaration of Conformity’ on this page.
This equipment is thus suitable for single terminal connection to the public switched telephone
network (PSTN) throughout Europe. However, due to the differences between the individual
PSTNs provided in different countries - and even within a country - the approval does not, of
itself, give an unconditional assurance of successful operation on every PSTN network, or
compatibility with every possible ring cadence.
When using the EURO-073-ARM on ADSL lines, ADSL filters must be
fitted. If ADSL filters are used they should be fitted at the
telephone line socket.
Should any difficulties be experienced, or it is required to use the unit on another network,
please contact your supplier in the first instance.
10.2.5
IMPORTANT NOTICE
The Declaration of Conformity to European R&TTE Directive for this product is valid ONLY when it
is correctly installed as described in these instructions.
These instructions are designed to ensure that SAFETY regulations are met, as well as functional
and programming aspects. It is therefore essential that these are followed exactly; in particular
the telephone cable must be routed and connected correctly.
The product declaration is for use with the following services ONLY:
Multi-Frequency signalling
Auto-Calling
Auto-Clearing
The declaration will be void if used for any other purpose.
The Declaration of Conformity for this product for attachment to the PSTN is void if it is subject
to any unauthorised modification, or if used with, or connected to:
Internal software which has not been approved.
External control software or control equipment which causes the unit to contravene the
requirements of telecommunications standards.