![PYROMANIA GAS4150-B Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/pyromania/gas4150-b/gas4150-b_feature-manual_1632720007.webp)
NSTALLATION INSTRUCTIONS
Continued
6
_________________________________________________________________________________________________
CONNECTIONS - NATURAL GAS (NG)
The supply hose is equipped with a 3/8” flare fitting and should be connected to a CSA certified manual shut off valve.
An adapter fitting may be required.
This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
The supply gas hose must not be run along areas where it may be a tripping hazard or subjected to accidental damage
(such as pathways, driveways and lawns).
Do not bury the gas supply line supplied by the manufacturer underground. They are not approved or certified for
underground use.
I