+12VDC-

 Pin 1 (Yellow wire) on the 

Hard Drive connector.  

12 VDC acceptor power.

Communication Ground- 

Pin 5 (Black 

wire) on the DB-9 connector. 

DC communication ground.

TXD Line-

 Pin 3 (Green wire) on the 

DB-9 connector. 

Connected to TXD line from your PC. (PC TXD line) 

RXD Line-

 Pin 2 (White wire) on the 

DB-9 connector. 

Connected to RXD line from your PC. (PC RXD line) 

 
MDB Mode of Operation 

Note: To enable this mode on the acceptor, make sure the Configuration Card has 
been configured for “MDB” mode. Our MDB interface uses the standard MDB 
connector (see Below) for communication. 

 
 

 
MDB Mode Power and I/O Connections 

 

Pin Location 

Pin Description

Pin 1 

+34 VDC Power

Pin 2 

DC power return

Pin 3 

Not used

Pin 4 

Master Receive

Pin 5 

Master Transmit

Pin 6 

Communications Common 

 
Parallel Mode of Operation 

Note: To enable this mode on the acceptor, make sure the Configuration Card has been 
configured for “Parallel” mode. The Parallel mode is compatible with the Innovative 
Technologies™ “Smiley™ bill acceptor.                 
In this mode, a single output is applied to one of four Vend lines to show which bill has been 
accepted. This allows you to have up to four denominations of bills to be accepted. Also provided 
in this interface is an Alarm line to indicate an abnormal condition. An Escrow line is also provided 
to allow more control over which bill is accepted by the Apex bill acceptor. 

This mode can be used in our 12 VDC models as well as our 120 VAC and 24 VAC models. 

Interface Operation 

The Inhibit line is used to enable the Apex bill acceptor. Pull it low to enable the acceptor, high to 
disable. The Alarm output will go low for 100 msec to signal an abnormality or error. A Vend Line 
will go low for 100 msec when a particular bill is recognized. Vend Lines 1-4 correspond to US bills 
$1, $5, $10 and $20. If the Escrow Line is not held low, the acceptor will accept a bill and send the 
appropriate signal via the Vend Line. If the Escrow Line is held low and a bill is inserted, the Apex 
bill acceptor will send out a “Credit” signal telling you what the value of the bill is (by toggling the 
appropriate Vend Line). If the Escrow Line is not brought high or the Inhibit Line goes high during 
a 30-second period, the bill will be rejected. If the user brings the Escrow Line high (and leaves the 
Inhibit line low) during the 30 second period, the acceptor will accept the bill and send out a “Vend” 
signal on the appropriate Credit Line. The Vend signal will not be issued if the bill jams or a 
“Stealing” attempt is seen by the acceptor. In this case, the bill will be rejected and the acceptor 
will toggle the Alarm Line. 

 
Parallel Mode Power and I/O Connections (Refer to Figure 1 for Pinouts) 

Pin Function & Location 

Apex 12VDC Version 

Apex 120 VAC or 24 VAC Version 

DC Ground-

 Pin 4 (Black wire) on the 

18-pin

 connector. 

DC communication ground and 
DC power ground. 

DC communication ground 

+12 VDC-

 Pin 11 (Red wire) on the 

18-

pin

 connector. 

12 VDC acceptor power 

Do not use this pin for 120 VAC 
version. 

Содержание APEX 5000 Series

Страница 1: ...APEX SERIES 5000 7000BILLACCEPTOR INSTALLATION OPERATION MANUAL Pyramid Technologies Inc 1718 North Quail Mesa Arizona 85205 USA 480 507 0088 FAX 480 507 1922 www pyramidacceptors com Rev V 06 28 11...

Страница 2: ...and advanced diagnostics via PC Many interfaces available Pinouts compatible with other manufacturers bill acceptors Dual stage optical anti stringing Simple configuration and setup including DIP Swit...

Страница 3: ...g for 12VDC unit only 9 24 VAC Version Ships with 9 pin 24 VAC harness Country Code Follows ISO three 3 digit Country Code Example USA United States Serial Number Description Example Serial Number S N...

Страница 4: ...s harness is needed for USB communication The harness comes with a USB connector on 36 of cable as well as a hard drive connector on 36 of cable to obtain 12 VDC power for the note acceptor from the P...

Страница 5: ...o install the acceptor disconnect all power to the machine Connect the interface cable from the machine to the acceptor On 120 VAC units connect the 9 pin power plug to the machine Install the green r...

Страница 6: ...the card use a black felt tip marker and fill the selected block completely making sure no marks are outside the block Note As a service to our customers Pyramid Technologies Inc will configure each a...

Страница 7: ...l hold the Configuration Card for a second or two then feed it back to you If the bezel lights are flashing rapidly the acceptor has read the Configuration Card correctly The configuration is now in p...

Страница 8: ...will put the acceptor into a Configuration Mode and it will expect to have the Configuration Card inserted next If you have accidentally entered this mode cycle the acceptor power and start again Loo...

Страница 9: ...ashes The cassette has been removed Replace the cassette 5 Flashes The acceptor is defective Replace the acceptor 6 Flashes The acceptor is not enabled Verify that the host has enabled the acceptor 10...

Страница 10: ...Serial Pulse or Yellow 3 120 VAC Hot Enable 4 DC Power Ground Black 4 120 VAC Hot Power Not used for 24 VAC model 5 TXD for Mars 600 or TTL RS232 Green 5 No Connection 24 VAC hot for 24 VAC model 6 No...

Страница 11: ...n 1 120 VAC Neutral Inhibit Green wire Connect to 120 VAC Neutral to disable acceptor If left floating may disable acceptor based on the state of the 120VAC Hot Enable line Note Low cost 120 VAC suppl...

Страница 12: ...n collector output transistor on Pin 1 Brown wire on the 18 pin connector 5 12 VDC at 40 mA Max In addition the 120 VAC model 24 VAC model and 12 VDC model have an Out of Service output located on Pin...

Страница 13: ...he Apex bill acceptor to the Host Message Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Hex V l 1 Credit 1 0 0 0 0 0 0 1 81H Not Used 1 0 0 0 0 0 1 0 82H 5 Credit 1 0 0 0 0 0 1 1 83H 10 Credit 1 0 0...

Страница 14: ...se customer installation Order RS 232 Communication Harness P N 05AA0009 to have this ability if you use RS 232 If you use USB order USB Communication Harness P N 05AA0023 This RS 232 mode uses a thre...

Страница 15: ...in our 12 VDC models as well as our 120 VAC and 24 VAC models Interface Operation The Inhibit line is used to enable the Apex bill acceptor Pull it low to enable the acceptor high to disable The Alar...

Страница 16: ...he 18 pin connector Open collector normally high output Pulled low for 100 msec when this bill is recognized Open collector normally high output Pulled low for 100 msec when this bill is recognized Cr...

Страница 17: ......

Отзывы: