6.
Storage Recommendations
b) For long-term storage (more than 3 months), the battery cells should be stored in the
temperature range of 5~45
℃
, relative humidity <65% and contains no corrosive gas
environment.
The battery module should shelfed in range of 5~45
℃
, dry, clean and well ventilated
environment. Before storage the battery should be charged to 50~55% SoC;
It is recommended to active the chemical (discharge and charge) of the battery every 3
months, and the longest discharge and charge interval shall not exceed 6 months.
Caution: If not follow the above instructions for long term store the battery, The cycle life will
have relative heavily reduction.
7.
Shipment
Battery module will pre-charged to 100%SOC or according to customer requirement before
shipment. The remaining capacity of battery cell, after shipment and before charge, is
determined by the storage time and condition.
1. The battery modules meet the UN38.3 certificate standard.
2. In particular, special rules for the carriage of goods on the road and the current dangerous
goods law, specifically ADR (European Convention on the International Carriage of Dangerous
Goods by Road), as amended, must be observed.