background image

Do not leave the batteries lying around in the open; there is the risk of them being swallowed by children

or domestic animals. If swallowed, consult a doctor immediately.

Make sure that the polarity is correct when inserting the batteries.

Remove the batteries when the device is not being used for long periods of time.

Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable protective

gloves.

Batteries must not be short-circuited or thrown into fire. There is a risk of explosion!

Never take the batteries/ apart!

Always exchange the complete set of batteries; do not mix full batteries with empty/half-empty batteries. Never use batteries

and accumulators together.

• Open the battery compartment on the back of the IR thermometer by sliding it in the direction of the arrow.

• Insert two micro-batteries (AAA) in the battery compartment observing the correct polarity. You will find the corresponding

illustration in the battery compartment.

• Close the battery compartment in reverse order.

• If the battery icon appears on the display, exchange the batteries immediately to prevent false measuring results.

Initial

Initial

Initial

Initial operation

operation

operation

operation

Operating

Operating

Operating

Operating principle

principle

principle

principle

IR thermometers measure the surface temperatures of objects. The device’s sensor measures the emitted, reflected and

penetrated

heat radiation of the object and converts this information into a temperature value.

Measuring

Measuring

Measuring

Measuring temperatures

temperatures

temperatures

temperatures

Direct the opening of the IR sensor onto the object or surface to be measured and press „MEAS“ (5).

As long as the button is kept depressed, the temperature is measured and displayed (the display shows „SCAN“). The last

measured value is displayed on the LC display (the display shows „HOLD“).

The IR thermometer shuts off automatically after approx. 12 seconds. Make sure that the surface to be measured is larger

than the measuring spot. The ratio of the distance to spot ratio (D/S) is 6:1 with this IR thermometer. This means, that with a

measuring distance of 60 cm, the measuring spot has a diameter of approx. 10 cm.

For exact measuring, the measuring object should be at least twice as large as the measuring spot (hold the IR thermometer

closer to the measuring object, if applicable).

The temperature displayed by the IR thermometer is the average temperature of this measuring spot!

Activating

Activating

Activating

Activating the

the

the

the laser

laser

laser

laser

A switchable laser enables the easier positioning of the measuring spot. Make sure that the laser point is approx. 16 mm

away

from the center of the measuring spot (see sketch).

Turn the IR thermometer on (button „MEAS“) and briefly press the button „LASER“ (6). A small laser icon appears on the

display

(triangle with a sun icon). Now the laser is activated automatically during measuring. To turn the laser off, press the button

„LASER“ (6) again and the laser icon on the display disappears again.

Содержание PMIR15

Страница 1: ...ue due due to to to to non compliance non compliance non compliance non compliance with with with with these these these these operating operating operating operating instructions instructions instructions instructions We We We We shall shall shall shall not not not not be be be be liable liable liable liable for for for for any any any any consequential consequential consequential consequential d...

Страница 2: ... heat radiation of the object and converts this information into a temperature value Measuring Measuring Measuring Measuring temperatures temperatures temperatures temperatures Direct the opening of the IR sensor onto the object or surface to be measured and press MEAS 5 As long as the button is kept depressed the temperature is measured and displayed the display shows SCAN The last measured value...

Страница 3: ...s off Raising the alarm level Lowering the alarm level Activating the temperature alarm OFF ON The measuring device emits a warning sound when exceeding the previously set alarm level Tips Tips Tips Tips and and and and information information information information The emission degree described the energy emission characteristics of a material The higher this value is the more radiation a materi...

Страница 4: ...d cadmium Hg Hg Hg Hg mercury Pb Pb Pb Pb lead You can return flat batteries rechargeable batteries free of charge to the collection points in your community our branches or anywhere else where batteries or rechargeable batteries are sold You will thus carry out your legal obligations and contribute to the protection of our environment Disposal Disposal Disposal Disposal Old electronic devices are...

Отзывы: