background image

Operation 

AC or DC Voltage Measurement 

1.  Set the function switch to the “

DCV

” position for DC voltage 

measurements, or “

ACV

” position for AC voltage measurements. 

2.  Touch the test probe tips to the circuit under test. Be sure to 

observe the correct polarity (red lead to positive, black lead to 
negative). 

3.  Read the voltage on the display  

Resistance/Continuity Measurement 

WARNING:

 To avoid electric shock, disconnect power to the unit 

under test and discharge all capacitors before taking any 
resistance measurements. Remove the batteries and unplug the 
line cords. Never measure continuity on circuits or wires that 
have voltage on them. 

1.  Set the function switch to the “ 

       •)))     ” position. 

2. Connect 

the 

test 

leads to the circuit to be measured. 

3.  Read the value on the display. 
4.  For Continuity tests, press the SELECT button until the “•)))“ 

symbol appears in the display. 

5.  If the resistance is less than 60 ohms, an audible tone will sound. 

 

 

 

 

 

 

 

Capacitance  Measurement 

WARNING:

 To avoid electric shock, disconnect power to the unit 

under test and discharge all capacitors before taking any 
capacitance measurements. Remove the batteries and unplug 
the line cords. Never measure continuity on circuits or wires that 
have voltage on them. 

1.  Set the function switch to the “ 

      •)))     ” position. 

2.  Press the SELECT button until “nF” appears in the display.  
3.  Press the RELATIVE button to zero the display 
4.  Connect the test leads to the capacitor to be measured. 
5.  Read the value on the display. 

Diode Test 

WARNING: 

To avoid electric shock, do not test any diode that 

has voltage on it. 

1.  Set the function switch to “ 

      

•)))

     “position. 

2.  Press the SELECT button once to enter Diode Test. The “   “ 

symbol will appear in the display. 

3.  Touch the test probe tips to the diode or semiconductor junction 

you wish to test. Note the meter reading. 

4.  Reverse the test lead polarity by reversing the red and black leads.  

Note this reading. 

5.  The diode or junction can be evaluated as follows: 

A.  If one reading shows a value and the other reading shows OL, 

the diode is good. 

B.  If both readings show OL, the device is open. 
C.  If both readings are very small, or 0, the device is shorted 

 

Frequency/Duty Cycle Measurement 

1.  Set the function switch to the “

HZ/DUTY”

 position. 

2.  Press the Hz/DUTY button once to display Duty Cycle %. Pressing 

the button again will toggle the display to frequency (Hz). 

3.  Touch the test probe tips to the circuit under test. Be sure to 

observe the correct polarity (red lead to positive, black lead to 
negative). 

4.  Read the value on the display. 

 

Features 

Relative Button

 

The relative measurement feature allows you to make measurements 
relative to a stored reference value. A reference voltage can be 
stored and measurements made in comparison to that value. The 
displayed value is the difference between the reference value and the 
measured value. 

1.  Perform the measurement as described in the operating 

instructions. 

2.  Press the RELATIVE button to store the reading in the display and 

the "REL" indicator will appear on the display. 

3.  The display will now indicate the difference between the stored 

value and the measured value. 

4.  Press the RELATIVE button to exit the relative mode. 

Note:

 The Relative function does not operate in the Frequency 

function. 

 

 

 

 

 

Data Hold Button 

The Data Hold function allows the meter to “freeze” a measurement 
for later reference

 

1. Press the “

DATA HOLD

” button to “freeze” the display, the 

HOLD

” indicator will appear. 

2. Press the “

DATA HOLD

” button to return to normal operation. 

 

Auto Power Off 

1.  To save power, the display automatically turns off in 30 minutes. 
2.  Press the SELECT button to turn display back on. 
3.  To cancel Auto Power Off, set the function switch to the off 

position. Hold down the SELECT button and turn the function 
switch to the desired position and release the SELECT button after 
3 seconds. 

 

 

Maintenance 

WARNING

: Disconnect the test leads from any source of voltage 

before removing the back cover or the battery/fuse door. Do not 
operate your meter until the rear housing is in place and fastened 
securely. 

Replacing the Battery 

1.  Remove the rubber holster (if in place) 
2.  Remove Philips head screw and lift off the rear housing of the 

meter. 

3.  Replace old battery with fresh CR2032 type button battery. 
4.  Replace the rear cover and secure the screw. 

Отзывы: