1-3-2
DVDN_ISP
Safety Check after Servicing
Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts, and
wires have been returned to their original positions. Afterwards, do the following tests and confirm the specified
values to verify compliance with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d’) between
soldered terminals, and between terminals and
surrounding metallic parts. (See Fig. 1)
Table 1: Ratings for selected area
Note: This table is unofficial and for reference only. Be
sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current
between B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals,
antenna terminals, video and audio input and output
terminals, microphone jacks, earphone jacks, etc.) is
lower than or equal to the specified value in the table
below.
Measuring Method (Power ON):
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use an AC
voltmeter to measure across the terminals of load Z.
See Fig. 2 and the following table.
Table 2: Leakage current ratings for selected areas
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
AC Line Voltage
Clearance Distance (d), (d’)
120 V
≥
3.2 mm (0.126 inches)
AC Line Voltage
Load Z
Leakage Current (i)
Earth Ground (B) to:
120 V
0.15
µ
F CAP. & 1.5 k
Ω
RES.
Connected in parallel
i
≤
0.5 mA Peak
Exposed accessible parts
Chassis or Secondary Conductor
Primary Circuit
Fig. 1
d'
d
AC Voltmeter
(High Impedance)
Exposed Accessible Part
B
Earth Ground
Power Cord Plug Prongs
Z
Fig. 2
Содержание E7A02UD
Страница 31: ...1 10 9 AV 2 5 Schematic Diagram E7A02SCAV2 ...
Страница 32: ...1 10 10 AV 3 5 Schematic Diagram E7A02SCAV3 ...
Страница 35: ...1 10 13 SW Schematic Diagram E7A02SCSW ...
Страница 38: ...1 10 16 SW CBA Bottom View SW CBA Top View BE7A00F01023B ...
Страница 50: ...1 16 2 E7A02PEX Packing Some Ref Numbers are not in sequence X5 Unit S1 A13 S2 S3 S2 X6 X10 X4 X3 X2 X1 ...
Страница 57: ...PY90DG E7A02UD 2006 6 12 ...