OPERATING AND MAINTENANCE MANUAL
PYD SERIES SOLAR INVERTER
38
b0-00 Engine class 2
b0-01 Control engine 0
d0-00 Motor power ( KW of motor )
d0-01 Motor Voltage (3~230V or 3~380V)
d0-02 Motor current (A, motor amperage)
d0-03 Motor frequency (depends on the model)
d0-04 Maximum motor revolutions per minute (depends on model)
d0-30 - 11 ---------- motor and pump already installed
d0-30 - 12 ---------- engine without hydraulics
Once you have selected 11 or 12, tune appears on the screen and you press the green RUN button
the inverter will start to study the motor to keep it always within its optimum values.
11 is for the start-up of a pump already installed in the well.
12 is for the motor without hydraulics for any test or failure detection out of the water.
b0-00 Engine class 0
b0-01 Control mode 2
d0-00 Motor power ( KW of motor )
d0-01 Motor Voltage (3~230V or 3~380V)
d0-02 Motor current (A, motor amperage)
d0-03 Motor Frequency (50-60 Hz)
d0-04 Maximum motor revolutions per minute ( 3000-3500 RPM )
7. ALARM CODES
Code
Name
Description
A-LP
Low voltage rest
If the value is lower than A1-09, the low voltage alarm shall be
activated.
A-LS
Light standby
If the conditions of A1-22/23 are met, the light standby alarm will
be activated.
A-LL1
Underload protection
If the conditions of A1-25/26 are met, the underload protection
alarm will be activated.
A-TF
Full protection
Set the DI terminal to 52, enable ON.
A-LL
Protection against lack of
water
Set DI terminal to 53, enable ON
6.2 Quick configuration for permanent magnet motor
6.1 Quick configuration for asynchronous motor