Reaction to the lack of the DMX signal
This function is used both to secure the installation against
disappearance of the DMX signal and to achieve the desired value without the
connection of an outer controller. On activating it, in case of no DMX signal,
the module will realize the selected option individually. The realized option will
be stopped automatically after re-connecting the DMX signal and the module
will realize commands sent through the DMX line again.
Sc
– programming the stage value in the range 0 – 255, for which the
available options are:
•
maintaining the last value
Hld
•
a signal from the analogue inputs
AnL
•
a signal from the buttons
diG
Apart from that, the transition parameters can be defined:
•
up time –
uPt
– the rise time in the push-button mode (from min to
max), time from 0 seconds to 24h
•
hold –
hLd
– duration in the push-button mode (in function 4), time
from 0 seconds to infinity
•
down time –
dnt
– falling time in the push-button mode, time from 0
seconds to 24h
11