DMX Controller Slave

User manual

Содержание PX710S+

Страница 1: ...PX710S DMX Controller Slave User manual...

Страница 2: ...etwork settings 14 4 9 Restart 15 5 Network settings of the controller 16 5 1 Change of the computer network configuration 18 5 2 Connecting controller directly to the PC 21 5 3 Connecting the control...

Страница 3: ...Connection scheme 37 12 Dimensions 38 13 Technical data 38 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e BDO r...

Страница 4: ...ls PX710M and 7 PX710S devices An advanced PC application PxDesigner Windows allows for programming the device The application has a built in library of devices that can be distributed on a graphic pr...

Страница 5: ...damage to a conductor it should be replaced with a conductor of the same technical parameters 4 Connection of DMX signal can be made with a shielded conductor only 5 All repairs connecting and disconn...

Страница 6: ...ctors and control elements Ethernet connector DMX output power supply 12 24V DC reset signaling diodes screen DMX output CAN bus control keys PX710S PX710S PX Art 192 168 1 101 RUNNING 01 10 2021 Fri...

Страница 7: ...ls the menu up or increases the values to be set enter allows to enter the programming mode and confirm the values set The symbol indicates the currently selected parameter which will be entered after...

Страница 8: ...us as well as date and time on the device PX710S 21320345 192 168 1 101 RUNNING 01 10 2021 Fri 11 23 Possible statuses are RUNNING normal device operation STOP the operation of the device is suspended...

Страница 9: ...00 000 000 009 000 000 000 000 DMX 1 1 12 001 126 090 240 188 005 000 000 000 000 009 000 000 000 000 channels 1 2 3 4 channels 9 10 11 12 4 3 2 Running scenes In the RUNNING SCENES menu on the CONTRO...

Страница 10: ...OUTPUT RUNNING SCENES RUNNING PROGRAMS No Running Programs is displayed on the screen when no program is running The list is refreshed when you enter the programs preview 4 4 Clock In the CLOCK menu y...

Страница 11: ...signal on and off while the prev and next buttons change the DMX channels or select the ALL option ENTER PX710S 21320345 192 168 1 101 RUNNING 01 10 2021 Fri 11 23 3 x NEXT CONTROLLER STATUS CLOCK TE...

Страница 12: ...ey ENTER PX710S 21320345 192 168 1 101 RUNNING 01 10 2021 Fri 11 23 3 x NEXT CONTROLLER STATUS CLOCK TEST CHANNELS LCD SETTINGS CONTROLLER STATUS CLOCK TEST CHANNELS LCD SETTINGS ENTER ENTER BRIGHTNES...

Страница 13: ...N in the menu first enter the old PIN and then enter the new one and confirm the changes by selecting Accept ENTER PX710S 21320345 192 168 1 101 RUNNING 01 10 2021 Fri 11 23 3 x NEXT CONTROLLER STATUS...

Страница 14: ...BER MAC FIRMWARE SERIAL NUMBER MAC FIRMWARE FIRMWARE VERSION 02 01 00 21 NEXT ENTER SERIAL NUMBER 21320345 MAC 70 B3 D5 FF A0 13 ENTER 4 8 Network settings In the controller on the screen the user can...

Страница 15: ...0 Mask 255 255 255 0 Device name Px710S serial number ADMIN account password serial number Remove configuration configuration can still be downloaded in PxDesigner RESET NETWORK reset network settings...

Страница 16: ...FACTORY DEFAULTS RESET NETWORK LOGOUT ALL USERS ENTER LOGOUT ALL USERS Are you sure NO YES 5 Network settings of the controller The controller stores the static network configuration It is always used...

Страница 17: ...255 0 Gate 192 168 0 1 If the controller operate in automatic mode in the network and receive IP address from the DHCP server the detaching of the network cable will result in the loss of IP address...

Страница 18: ...onfiguration varies depending on the operating system Windows 10 system is an example here Change of the computer network configuration in the Windows 10 operating system in done in the following 1 Cl...

Страница 19: ...Right click on the appropriate connection for example it could be Ethernet and select Properties 6 In the new window that appears select Internet Protocol Version 4 TCP IPv4 and then press properties...

Страница 20: ...ect Use the following IP address To connect directly computer driver with a controller that has a default configuration use the sample settings IP address 192 168 0 51 Subnet mask 255 255 255 0 Defaul...

Страница 21: ...onnecting the controller using a router When connecting the controller to the router there are two options for network settings The first of these is the use router with a DHCP server running the netw...

Страница 22: ...1 Automatic addressing Below is a diagram of the operation of devices with the DHCP server running PC DHCP On Router IP 192 168 0 100 Mask 255 255 255 0 DHCP On PX710S Settings from DHCP DHCP On PX710...

Страница 23: ...255 0 DHCP Off PX710S IP 192 168 0 50 Mask 255 255 255 0 Gate 192 168 0 1 DHCP Off PX710S 6 Logging into the controller Logging into the controller is possible from the local network and from externa...

Страница 24: ...the device from an external network via the internet for this purpose it should be have an external IP address on the router assigned by the internet provider and be able to establish connection from...

Страница 25: ...MAC address 70 B3 D5 EF B1 60 the IP address 192 168 1 15 will always be assigned by the DHCP server example below Most routers available on the market usually have several parameters in port forwardi...

Страница 26: ...local network with the following settings external IP address 66 77 88 99 example address IP address 192 168 1 10 mask 255 255 255 0 target device port 50000 and 50001 protocol TCP or TCP UDP in this...

Страница 27: ...controller from the external internet network in the application click Connect then select the option Remote login and then in the IP field enter the IP address of the router assigned by the internet...

Страница 28: ...P address e g 66 77 88 99 INTERNET PX710S IP 192 168 1 10 Mask 255 255 255 0 Gate 192 168 1 1 DHCP Off Router IP 192 168 1 1 Mask 255 255 255 0 DHCP Off Redirecting port 50000 and 50001 to the device...

Страница 29: ...IP address of the second controller 192 168 1 11 mask 255 255 255 0 target device port 50000 and 50001 for the first controller 60000 and 60001 for the second controller for ports 60000 and 60001 the...

Страница 30: ...ample internet connection external IP address e g 66 77 88 99 50000 66 77 88 99 60000 66 77 88 99 50000 66 77 88 99 60000 INTERNET PX710S IP 192 168 1 11 Mask 255 255 255 0 Gate 192 168 1 1 DHCP Off P...

Страница 31: ...irmware update NOTE The firmware update is recommended to be downloaded from the product page as there is always the latest version of the device firmware update 7 1 Windows The PxDesigner software ca...

Страница 32: ...5 Select the start menu in which you want to create a shortcut to the program You can also rename the directory then click Next 6 The installer will ask again whether you want to install the software...

Страница 33: ...the PX710M The PX710S controller should be loaded with the same configuration as for the PX710M 9 Live mode When connected to a computer or a smartphone the controller can be switched to live mode In...

Страница 34: ...plication INPUTS not used in PX710S blue DMX flashing the DMX signal is sent yellow POWER permanent light the device is running and working in normal mode fast flashing the device is running and has s...

Страница 35: ...e built in memory to the device Holding down the button for 5 seconds in the normal operating mode Network settings reset signaled by lighting up the DMX diode and the POWER diode Holding down the but...

Страница 36: ...controller from the ADMIN account level by providing the default password device serial number even if it has been changed Direct connection cable assumptions a computer with a stable IP in the same s...

Страница 37: ...guration 11 Connection scheme power supply 12 24V DC V V L N DMX controller PX710M PX710S PX710S PX Art 192 168 1 102 RUNNING 01 10 2021 Fri 11 23 max 7 PX710S modules 120 Ohm terminator 120 Ohm termi...

Страница 38: ...ata type PX710S power supply 12 24V DC max power consumption 2W DMX output 2 2 x 512 channels Ethernet port 1 Real Time Clock RTC yes Modbus TCP scenes and programs steps 251000 number of scenes runni...

Страница 39: ...zones 32 users including ADMIN 16 weight 0 3kg dimensions width 157mm 9 DIN rail modules height 86mm depth 60mm possibility of expansion using PX710S max 7 39...

Страница 40: ...0 2018 EN 61000 4 2 2009 EN IEC 61000 6 1 2019 EN IEC 61000 6 3 2021 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL...