8
Signaling of indicators
The controller is equipped with two indicator lights:
Indicator
Normal operation
Bootloader mode
PWR
indicator lights
continuously
indicator blinks
DMX
indicator blinks
indicator is off
9
Firmware upgrade
The procedure for firmware upgrade on the PX333 controller:
1. Connect the controller directly to the computer using a network cable.
For older computers, it is recommended to use a crossover cable –
the cable is attached to the controller.
2. Set the following parameters on the computer network interface card:
IP address: 192.168.0.1
mask: 255.255.255.0
(for more information, see chapter 5.1 Change of the computer
network configuration)
3. While holding down the default settings button (located in the hole in
the side of the controller housing), turn on the power supply of the
controller.
4. The orange PWR indicator of the controller should blink (the blue DMX
indicator in inactive).
5. Run the “
PX333_FLASHER.exe
” program on your computer.