background image

PX255

DMX/DALI/DMX

Interface

User manual

Содержание PX 255

Страница 1: ...PX255 DMX DALI DMX Interface User manual...

Страница 2: ...virtual ballasts 15 7 2 DMX DALI DMX to DALI patching 15 7 3 DALI DMX DALI to DMX patching 17 7 4 Screensaver 18 7 5 DMX Out settings 19 7 6 Input DMX preview 24 7 7 Language 25 7 8 Firmware version 2...

Страница 3: ...individual lamps or groups of devices user can create up to 16 groups Additionally for each of the lamp ballast it is possible to define a number of individual parameters such as minimum and maximum...

Страница 4: ...vent of any conductor damaging it should be replaced with the one of the same technical data 4 Connection of DMX signal should be made with shielded conductor 5 All repairs and connections of outputs...

Страница 5: ...tton is described on the right side and their use is as follows exits from the currently programmed parameter without saving the changes or goes to the higher level in the menu pressing the escape but...

Страница 6: ...Use of the device After switching on the screen shows the main window menu which summarizes the device status It describes all of the input signals of the PX255 If the device receives the DMX signal i...

Страница 7: ...ific address of DALI ballast This address can be read from a visualization on the screen It is the sum of the visible at the beginning of each row and column Red bars indicates no conversion of DMX si...

Страница 8: ...case of working mode DMX 512 to DALI the PX255 transmits the processed DMX signal directly to the DALI protocol 6 Main menu At the bottom of the Summary screen a menu screen button is placed Once appr...

Страница 9: ...propriate option with or buttons and confirm the selection by pressing enter button Remarks Ballast is a device plugged in to the DALI bus Typically this is part of the lamp but it may also be other D...

Страница 10: ...us Error message After reading the parameters on the screen is show picture visible above All ballasts option allows to change the settings for all devices visible on the DALI line Consecutive found b...

Страница 11: ...er switching on 0 light is off 254 full brightness 100 System error level range 0 254 The brightness level of the lamp when on the control bus there is an error 0 light is off 254 full brightness 100...

Страница 12: ...rightness of the lamp for the specified scene 0 254 the brightness level of the scene 255 the scene is not set Scenes are parameterized for each ballast separately by DALI controller PX255 allows to m...

Страница 13: ...tes that the lamp has lost its address 7 1 2 Ballasts reset Ballast reset allows to restore the default settings for all ballast and each individual To reset all ballasts at the same time select the A...

Страница 14: ...o Adr 63 The device is finding ballasts separately and each should be addressed individual In case you choosing Auto option the PX255 automatically assigns the next found ballasts addresses 00 to 63 7...

Страница 15: ...user in this menu can further reduce the number of such ballast to zero To change the parameters proceed similarly as in the previous paragraph 7 2 DMX DALI DMX to DALI patching This option allows you...

Страница 16: ...er button Remarks Number of visible ballasts available for lamps depends on the number of units declared by the user during the selection of the amount of ballast on the menu DALI Ballast number The d...

Страница 17: ...as follows select a specific ballast using the keys or and confirm by pressing enter Then the selected option is highlighted in blue and the using buttons or you can change the value of the DALI ball...

Страница 18: ...need to select the Screensaver Off button and press enter After this the box next to the text Screensaver On will be filled in To deactivate press one more time enter button When you select Screensave...

Страница 19: ...512 protocol describes exactly the way according to which data is sent The basic element of each data transfer protocol is a low or high level of voltage on the line called a bit Its duration in the...

Страница 20: ...ble with catching up to such a short pulse That is why in 1990 the change of the MAB to 8 microseconds was introduced After transferring the MAB a controller is obliged to send a START CODE byte The c...

Страница 21: ...e maximum transmission change rate value is 836Hz for 24 channels and in the second case only 44hZ for 512 channels This is quite a serious limitation whose effects can be observed during fast movemen...

Страница 22: ...to a specific device If you experience any problems we recommend using bigger lengths of Break Time MAB MBF and packet gap 1 Break Time allows to change the length of the interval between successive...

Страница 23: ...using floppy disc button and confirm with enter 3 MBF Mark Between Frame the amount of time if any between the end of one frame end of the 2nd stop bit and the start of the next Mark Time Between Fram...

Страница 24: ...u can limit the number of channels sent from PX255 The minimum value is 24 channels and the maximum is 512 default 7 6 Input DMX preview This menu allows to check the current DMX signal received by th...

Страница 25: ...Language settings allows to change the menu language To do this select appropriate language using or buttons and press enter 7 8 Firmware version This option allows to check the firmware and bootload...

Страница 26: ...MX control cable That means that DMX line from the signal source must be connected to DMX IN pins of PX255 and later directly from DMX OUT pins to the next device in DMX chain If the PX255 is the last...

Страница 27: ...9 Connection scheme 27 DALI DMX Converter DC OK DMX controller 24V DC power supply Next DMX devices e g lamp Ballasts DALI bus GND...

Страница 28: ...10 Dimensions 28 105 mm 86 mm 58 mm DALI DMX Converter...

Страница 29: ...512 channels DMX output 1 512 channels DALI channels 64 virtual DALI ballasts 64 number of device groups 16 power consumption max 7W 10V output 0 1mA output connections terminal blocks USB weight 0 2k...

Страница 30: ...wing directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment T...

Отзывы: