PVI Industries PV500-2 Скачать руководство пользователя страница 2

PV500-2  06/10 

 

 

Section 2 

 
 

ELECTRICAL 

 

1.  Wiring to the unit should conform to the National 

Electrical Code or the code legally authorized in your 
locality. A fused disconnect switch should be used for 
the water heater control. 120V, 1ph, 60 Hz service 
wiring is brought to the terminal block in the lower part 
of the enclosure on the water heater. See Figures 2-
2, 2-3 and 2-4. 

 
 

FOR YOUR SAFETY 

 
USE ONLY COPPER WIRE OF PROPER SIZING 
FOR INCOMING SERVICE. DAMAGE RESULTING 
FROM USE OF ALUMINUM WIRING WILL BE 
EXCLUDED FROM COVERAGE UNDER THE 
WARRANTY OF THIS UNIT. 

 
 
 
 
 

Typical 24 Volt Control System 

 

Figure 2-2 

 

Typical 24 Volt Control System 

with Damper 

 

Figure 2-3 

 
 

Typical 120 Volt Control System 

 

Figure 2-4 

 

Содержание PV500-2

Страница 1: ...iting device 10 Drip leg set at 200 F 11 Gas supply line 5 Upper operating thermostat 12 Handhole cleanout set at 130 F 6 Operating thermostat set at 120 F Not furnished by PVI CAUTION TEMPERATURES HI...

Страница 2: ...wiring is brought to the terminal block in the lower part of the enclosure on the water heater See Figures 2 2 2 3 and 2 4 FOR YOUR SAFETY USE ONLY COPPER WIRE OF PROPER SIZING FOR INCOMING SERVICE D...

Страница 3: ...e combustion products either to existing overhead breeching or to an appropriate outside location 1 The control manufacturer s installation and service manual and start up procedures for the control s...

Страница 4: ...mostat setting the control circuit opens which closes both the pilot and main burner gas valves terminating burner operation 6 The flue damper is closed NOTE The spark ignition system provides additio...

Страница 5: ...dilution with ambient air from the draft diverter occurs in the vent 6 Insert temperature gauge in hole and read vent temperature Temperature should be at least 300 F but less than the room temperatu...

Страница 6: ...d the tank inspected for scale buildup If scale is present it can be loosened with a high pressure stream of water The smaller pieces can be flushed through the drain and the larger pieces removed by...

Страница 7: ...llows a Turn off all power and fuel supplies b Drain and flush tank as previously discussed c Tag power switch es indicating that fuel is off and tank is empty d To restart refill tank with water and...