Spectra UV
Revision D
/
January 2022
Page 44 of 47
34B
Figure 35: Slide the Adjustment Handles
3.
175B
Turn the adjustment handles clockwise to tighten them and keep the set position.
442B
Note: Both sides must be adjusted evenly.
Irradiance and Dose
Refer to your material manufacturers recommendations for UV irradiance and dose
requirements for your material.
•
Irradiance
: Irradiance is the intensity of the UV. The maximum irradiance is
achieved with the lamp assembly at 2.1 in (53.3 mm) from the target (see Section
14.2). Distances farther and closer will result in lower intensity.
•
Dose
: UV dose is a function of irradiance and time. Slowing down the conveyor
speed will increase time, therefore increase the total UV dose.