MR2 Manual
Revision B
/
June 2021
Page 29
of
34
Damaged Valve Gasket
If material leaks from between the air body and metering sleeve, on the side of the valve, the
valve gasket is worn. To replace the valve gasket, follow the steps below:
1.
Use a 3 mm hex key to remove the six M4x16 bolts on the front of the air body.
Figure 58: Remove the Air Body Bolts
2.
Remove the air body.
3.
Remove the valve gasket. Carefully lift it off and clean off any material.
Note: If you have a two-part material, do not mix them or they will cure. If the material
has mixed you may need to disassemble and clean the MR2.
4.
Examine the valve gasket for any cracks or signs of wear. If the valve gasket is worn,
replace it. DO NOT flip the valve gasket over.
5.
Install the new valve gasket.
6.
Install the air body.
7.
Install the six M4x16 bolts. Tighten them in an “X” pattern.