Assemble Sections
1)
Be sure the micrometer adjustment (13) is backed out far enough so at least the
number 1 can be seen on the gauge (D).
2)
Apply a small amount of silicone grease to the end of the needle (3) and insert it
into the packing nut (6). Connect the sections using the two machine screws (22)
tightening them down evenly using a 3/32” Allen key.
3)
Using the tip of a 3/32” Allen key, tighten the packing nut (6).
Spare Parts
PVA offers standard spare parts kits for all dispensing valves. These kits are
stocked for immediate shipment and allow replacement of all wearable parts of the valve.
The spare parts kit for the FC100-CF, product number
FC1-C4-SP
, includes the
following components:
FC1-C4-SP
Includes:
Qty Part
Number
Description
1 V302
Seat
1 114-5247
Needle
1 V305
Packing, Teflon
2 VLV-014B
O-ring, Buna
1 VLV-007B
O-ring, Buna
2 VLV-006K O-ring, Kalrez
1 VLV-004B
O-ring, Buna
1 PT17184
Micrometer
Adjust Wrench
Micrometer Adjustment Breakdown
Содержание FC100-CF1
Страница 9: ......