Tool Kit
PVA offers standard tool kits for all dispensing valves. The tool kit for the
FC100-CF is part number
B12-1986
, which includes all necessary tools and lubricating
grease to perform maintenance on this dispense valve:
B12-1986
Includes:
Qty Part
Number
Description
2 0266244
8”
Adjustable Wrench
2 26563
3/32”
Allen
Key
1 26561
5/64”
Allen
Key
1 26559
1/16”
Allen
Key
1 5516A18
Tweezers
1
B62-0752
2.5cc Mineral Oil Lubrication Kit
1 B62-2048
2.5cc Silicone Lubricant
1
9570K71
Hook and Pick Set
1 0266255
Pliers
2
53085A61
Soft Plastic Covers for Pliers
1
PB135/2
Micrometer Screw Driver, #2
1 PT17184
Micrometer
Adjustment Wrench
1
MM115
Removable Thread Locker
Operation
Refer to assembly drawing
112-2541
for part reference numbers.
1)
Plumb up the valve as outlined above in the
Setup
procedures.
2)
Regulate the air pressure operating the valve between 60-100psi.
3)
Making sure that the valve is not aimed toward anyone, cycle the valve several
times. When the valve is cycling, the piston can be heard hitting the micrometer
adjustment, and the needle (3) can be seen going up and down in the center. If the
valve is not cycling properly, refer to the
Troubleshooting
section.
4)
When the fluid delivery system is connected to the valve, pressurize the material
to be dispensed.
5)
Once again, cycle the valve open to purge. Fluid should begin to dispense from
the for tip nozzle of the valve, continue dispensing until all air is removed.
6)
Check fluid connection and packing nut (6) for leaks. If the valve is leaking, refer
to the
Troubleshooting
section.
7)
Turn the micrometer adjustment (13) until the desired flow rate is achieved.
Turning the adjustment clockwise toward zero will decrease the material flow rate
and counter-clockwise will increase the material flow rate. If the micrometer
adjustment is turned all the way down to zero, it will stop fluid flow entirely.
8)
Once the micrometer setting is determined, the collar (E) on the micrometer (13)
can be turned clockwise to lock the adjustment.
Note: Refer to
Troubleshooting
section for any problems.
Содержание FC100-CF1