Shutting Down Valve 

 

At the end of the day or shift, it is necessary to shut down the CAM200 dispense 

system properly in order to keep material from curing inside the valve.  
 

1)

 

Remove the disposable dispense tip from the luer adapter (9) and discard. 

2)

 

Thread a luer lock plug onto the luer adapter (PVA part # PV-LLCAP) 

3)

 

Relieve fluid pressure on the valve by turning off air pressure from the fluid 
reservoir. 

 
 

 

Starting Up Valve 

 

At the beginning of the day or a shift it is necessary properly set up the CAM200 to 

resume normal operation.  
 

1)

 

Remove the luer lock plug from the luer lock adapter (9) and discard. 

2)

 

Place a new dispense tip onto the luer lock adapter (9). 

3)

 

Apply fluid pressure to the valve by turning on the pressure to the fluid reservoir. 

4)

 

Cycle the valve to the open position to bleed all air that may have become trapped 
when changing the needle tip. 

 

 
 
 

Tool Kit 

 

PVA offers standard tool kits for all dispensing valves. The tool kit for the 

CAM200 is part number 

B12-2113

, which includes all necessary tools to perform 

maintenance on this dispense valve: 

B12-2113

 Includes: 

 

Qty 

Part Number 

Description 

0266244 

8” Adjustable Wrench 

7122A38 

0.050” Allen Key 

26569 

9/64” Allen Key 

9570K71 

Hook and Pick Set 

 
 

Содержание CAM200

Страница 1: ...CAM200 DIAPHRAGM DISPENSE VALVE Version B12 2112 Rev C Operation Manual 1 MUSTANG DRIVE COHOES NY 12047 PHONE 518 371 2684 FAX 518 371 2688 info pva net www pva net ...

Страница 2: ...style body to make it more ergonomic for a variety of handheld applications The all plastic construction allows adhesives such as Cyanoacrylates and Anaerobics to be dispensed through the valve along with a variety of other low to medium viscosity fluids Applications can include dispensing dots beads or for potting The CAM200 has one body to house the fluid and piston lever section These include 1...

Страница 3: ...lace with the spring loaded piston When the lever of the valve is depressed the plunger lifts off the diaphragm and fluid is allowed to dispense When the lever is released the spring will again force the plunger into the diaphragm to return the valve to the closed position Note that the valve is normally in the closed position Fluid is supplied to the CAM200 through the 1 8 npt port located on the...

Страница 4: ...to resume normal operation 1 Remove the luer lock plug from the luer lock adapter 9 and discard 2 Place a new dispense tip onto the luer lock adapter 9 3 Apply fluid pressure to the valve by turning on the pressure to the fluid reservoir 4 Cycle the valve to the open position to bleed all air that may have become trapped when changing the needle tip Tool Kit PVA offers standard tool kits for all d...

Страница 5: ...tine Cleaning and Disassembly Cleaning and rebuilding the valve will be required from time to time A spare parts kit part CAM2 SP is available with all the normal wear parts included 1 If possible flush the valve thoroughly with an appropriate solvent before disassembly Refer to MSDS sheets of fluid for suggested solvent 2 Begin disassembly by first removing fluid pressure from the system 3 Remove...

Страница 6: ...Allen key thread the set screw 11 into the stroke adjustment 11 7 Place the diaphragm 2 onto the groove of the fluid section 3 with the thin Teflon side down against the fluid 8 Mount the top cap 1 over the diaphragm 2 and assemble to the fluid section 3 using the four socket head cap screws 12 tightening them down evenly with a 9 64 Allen key 9 Tighten the two set screws 11 that thread into the s...

Страница 7: ......

Страница 8: ...ispense needle Replace diaphragm Flip valve upside down and cycle until air bubbles are removed Valve does not dispense anything Fluid pressure is too low Material cured in fluid section Worn diaphragm Increase fluid pressure above 15psi Disassemble and clean valve Replace diaphragm Air bubbles in fluid Valve not properly purged Problem with fluid delivery system Flip valve upside down and cycle u...

Страница 9: ...es extend only to the original purchaser Third party warranty claims will not be honored at any time Prior to returning a product for a warranty claim a return authorization must be obtained from PVA s customer service department Authorization will be issued either via the telephone facsimile or in writing upon your request To qualify as a valid warranty claim the defective product must be returne...

Отзывы: