![PURSUIT OS 325 OFFSHORE Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/pursuit/os-325-offshore/os-325-offshore_owners-manual_1628328042.webp)
5-2
Section 5
Plumbing System
OS 325
mulation on the drain strainer, the box
should be cleaned out to prevent degrada-
tion in performance or potential stoppage in
the system.
Water Heater
The water heater is located below the pas-
sage aft-berth access hatch located under
the aft-berth mattress. All water heaters
have an AC element that is thermostatically
controlled at the heater and activated by a
circuit breaker located in the AC panel. A
high pressure relief valve protects the sys-
tem from excessive pressure. Make sure all
air is purged from the water heater and lines
before activating the water heater breaker.
Refer to the water heater manual for addi-
tional information.
Shore Water Connection
The shore water connection allows the direct
connection of the water system to a shore
side water supply. This provides the system
with a constant supply of fresh water and
minimizes the pressure pump operation. A
female inlet fitting is mounted on the port
side wing in the splash well.
To use shore water, connect a hose from the
shore water faucet to the shore water fitting
on the boat, then turn on the shore water.
The pressure pump will not run and the
water in water tank of the boat will not be
used. Also, the water tank will not be filled by
connecting to shore water.
5.2 Raw Water Washdown
The raw water washdown system pump is
supplied by hoses connected to a ball valve
and a thru-hull fitting located in the bilge.
Operation
Make sure the ball valve is open before
attempting to operate the raw water wash-
down system. The pump is activated by the
“Washdown” switch located on the helm.
When activated, the pressure switch will
automatically control the pump. As pressure
builds in the washdown hose, the pump will
shut off. When the washdown hose is in use
and the pressure drops, the pump will turn
on. Turn the switch off when the washdown
is not in use. The raw water washdown is
equipped with a sea strainer on the intake
side of the pump, located in the aft bilge;
check it frequently and clean as necessary.
Priming the System
Open the ball valve and hose connector, and
activate the pressure pump. Run the pump
until all air is purged from the system. Close
the thru-hull ball valve before the boat is
hauled from the water to eliminate an air
lock in the system. It may be necessary to
re-prime the raw water system if the system
is not used for an extended period.
NOTICE
DO NOT turn on water heater until it is
filled and primed; damage to the
heater will result.
NOTICE
DO NOT change or modify the shore
water inlet connector without contact-
ing Pursuit Customer Relations or
your dealer. Use of the wrong type or
a modification can damage the fresh
water system.
NOTICE
DO NOT operate high-pressure pump
dry, damage to pump will result. Turn
the raw water pump switch "OFF"
when leaving the boat unattended.
Содержание OS 325 OFFSHORE
Страница 1: ...March 2015...
Страница 2: ...U S Patents 8 113 137 8 191 495 Other Patents Pending...
Страница 4: ......
Страница 10: ...6 Operator Notes OS 325...
Страница 22: ...2 8 Operator Notes OS 325...
Страница 28: ...3 6 Operator Notes OS 325...
Страница 31: ...Electrical System 4 3 Section 4 OS 325 Main Distribution Panel MDP...
Страница 48: ...5 8 Operator Notes OS 325...
Страница 50: ...6 2 Operator Notes OS 325...
Страница 56: ...7 6 Operator Notes OS 325...
Страница 62: ...8 6 Operator Notes OS 325...
Страница 70: ...9 8 Operator Notes OS 325...
Страница 90: ...11 8 Operator Notes OS 325...
Страница 96: ...12 6 Operator Notes OS 325...
Страница 102: ...A 6 Operator Notes OS 325...
Страница 104: ...B 2 Appendix B Maintenance Log OS 325 Date Hours Dealer Service Repairs Maintenance Log...
Страница 105: ...Maintenance Log B 3 Appendix B OS 325 Date Hours Dealer Service Repairs...
Страница 106: ...B 4 Appendix B Maintenance Log OS 325 Date Hours Dealer Service Repairs...
Страница 107: ...Boating Accident Report C 1 Appendix C OS 325 Boating Accident Report...
Страница 108: ...C 2 Appendix C Boating Accident Report OS 325...
Страница 109: ...Boating Accident Report C 3 Appendix C OS 325...
Страница 110: ...C 4 Appendix C Boating Accident Report OS 325...
Страница 111: ...Boating Accident Report C 5 Appendix C OS 325...
Страница 112: ...C 6 Appendix C Boating Accident Report OS 325...
Страница 114: ...D 2 Operator Notes OS 325...
Страница 118: ...E 4 Operator Notes OS 325...
Страница 119: ...Schematics F 1 Appendix F OS 325 Schematics...
Страница 120: ...F 2 Appendix F Schematics OS 325...
Страница 121: ...Schematics F 3 Appendix F OS 325...
Страница 122: ...F 4 Appendix F Schematics OS 325...
Страница 123: ...Schematics F 5 Appendix F OS 325...
Страница 124: ...F 6 Appendix F Schematics OS 325...
Страница 125: ...Schematics F 7 Appendix F OS 325...
Страница 126: ...F 8 Appendix F Schematics OS 325...
Страница 127: ...Schematics F 9 Appendix F OS 325...
Страница 128: ...F 10 Appendix F Schematics OS 325...
Страница 129: ...Schematics F 11 Appendix F OS 325...
Страница 130: ...F 12 Appendix F Schematics OS 325...
Страница 131: ...Schematics F 13 Appendix F OS 325...
Страница 132: ...F 14 Appendix F Schematics OS 325...
Страница 138: ...F 20 Appendix F Schematics OS 325...
Страница 148: ...F 30 Appendix F Schematics OS 325...
Страница 149: ...Schematics F 31 Appendix F OS 325...
Страница 160: ...F 42 Appendix F Schematics OS 325...
Страница 161: ...Schematics F 43 Appendix F OS 325...
Страница 162: ...F 44 Appendix F Schematics OS 325...
Страница 163: ...Schematics F 45 Appendix F OS 325...
Страница 164: ...F 46 Appendix F Schematics OS 325...
Страница 165: ...Schematics F 47 Appendix F OS 325...
Страница 166: ...F 48 Operator Notes OS 325...
Страница 167: ......
Страница 168: ......