Purmo Group, Gateshead, NE11 0PG; Purmo Group Newcastle West, V42 TD39

DSHI-001 

Information for the installer:

These radiators are for use on two pipe 

pumped indirect domestic and commercial 

heating installations, with a maximum working 

temperature of 100°C.

The system should be designed in accordance 

with BS EN 12828:2012+A1:2-14 or BS EN 

12831-1:2017 as appropriate, with particular 

care to avoid air entry or water discharge. 

The installation work must be carried out in 

accordance with recognised good practice, 

and precautions taken to avoid contamination 

which could lead to corrosion. In accordance 

with current Building Regulations a corrosion 

inhibitor or other suitable water treatment must 

be used. The manufacturer’s instructions must 

be strictly followed.

Failure to comply with these standards might 

invalidate the manufacture’s warranty. 

10 Year warranty.

The recommendations of BS 7593, Code of 

Practice for treatment of water in domestic 

hot water central heating systems, should be 

followed where appropriate. 

4

46

20

52

11.5

20

20

100 Min

126

E24

184

20

20

100 Min

77

38

E12

20

20

100 Min

139

80

H22

20

20

100 Min

99

60

H21

20

20

100 Min

99

60

H20

20

20

100 Min

77

38

H11

20

20

100 Min

77

38

H10

Hanging Brackets

LN2 Bracket

A2 Wall Bracket

Bottom of radiator
mounting lug

Bottom of radiator
mounting lug

Installation Procedure:

1.  Decide on the position of the radiator and 

mark the mounting bracket fixing holes. 

Note: 

Wall brackets should be mounted 

in the centre of the radiator backstraps to 

allow for movement.

2.  Drill and plug the bracket fixing holes and 

fix the brackets securely to the wall.

3.  Mount the radiator on the brackets and 

connect the radiator to the heating system.

4.  Fit the plug and vent to the radiator.

5.  Fill the system and vent the radiator. 

6.  Balance the system to ensure correct flow 

through all radiators.

Horizontal Flat Tube Radiator

Models*: H10, H11 (FF/RF), H20, H21(FF/RF) H22 (FF/RF) 

(E12 & E24 LST only)

*

 FF = Full Fin, RF = Reduced fin

20

20

100 Min

126

E24

184

20

20

100 Min

77

38

E12

20

20

100 Min

139

80

H22

20

20

100 Min

99

60

H21

20

20

100 Min

99

60

H20

20

20

100 Min

77

38

H11

20

20

100 Min

77

38

H10