Español
U
ser Manual
14
01:48 29-Mar.
MR 03.98/04.00
MENU
REGEN
UP
DOWN
6.3 RIDER TIMER
TIMER DESCRIPTION
RIDER softeners are equipped with an advanced elec-
tronic timer that can easily control the working of the
system. This timer is equipped in the upper part of the
cabinet.
RIDER timers supply a lot of information about the ope-
ration of the system.Moreover it allows to adjust all the
internal parameters of the system.
Front part of the timer:
• DISPLAY LCD:
It supplies information about the sof-
tener. Depending on the stage in which the system is the
timer will supply different types of information:
Service: Information about softener working
Regeneration: Current stage is showed in the lcd display
Programming: The display shows all the internal para-
meters and allows to modify them.
“MENU” KEY: Allows entering inside the internal progra-
ming and confirms the amended parameters in any stage
of programming .
“UP” Y “DOWN” KEYS: Allow to navigate among the di-
fferent parameters. In programming allow to modify the
selected parameters.
“REGEN” KEY: It is used to start automatic regenera-
tions.
PROGRAMMING BLOCKAGE: After some seconds wi-
thout pressing any key the timer will be blocked automa-
tically for safety. The following message will be showed:
To unlock the timer, please press “
MENU” key for 3 se-
conds.
6.4 Start-up programming
RIDER softeners are configured to work with delayed re-
generations (02.00 am).
Programming:
1. Connect the provided transformer to the electrical
connector at the back of the system. The timer will show
service position.
IMPORTANT: After connecting the system can show fo-
llowing message:
This message indicates that the system is placing itself
in service position.If after two minutes this message is
still in the display please contact your distributor.
2. Press “MENU” key for three seconds to enter into the
internal programming. By pressing
“UP” y “DOWN” keys
the different parameters can be selected,and pressing
REGEN key we can access to modify it (selected parame-
ter flashes). With
“UP” y “DOWN” keys we can modify
the selected parameter and pressing
REGEN key one final
time the parameter will be confirmed. Parameters that
you can modify are as follows:
HOUR OF DAY: Format 0:00-24:00.
LANGUAGE: Spanish or English
UNITS : Metric system or US units
TYPE OF REGENERATION: There are several as follows:
Time initiated
(--) Delayed regenerations according to se-
lected frequence (Ex: Regenerates every 3 days at 02:00
am ).
Meter immediate: (MI) Regenerations are stated as per
treated volume of treated water. When remaining volume
is 0 starts a regeneration.
Delayed regenerations: (MD) Regenerations are dela-
yed according to volume. When the remaining volume is
finished the system starts the regeneration the same day
at the programmed hour.
Mixed regeneration
(MR) Similar to delayed regeneration
but it allows to program a máximum period of time be-
tween regenerations.
NOTE: Mixed regenerations are recommended. If you
want to select another type of regeneration, please con-
Volume(m3) =
Exchange capacity (º HFxm3)
Hardness (º HF)
Содержание Rider
Страница 1: ...User Manual Household Softener MU ...
Страница 2: ......
Страница 19: ...Español 19 User Manual ...
Страница 21: ...Español 21 User Manual NOTES ...
Страница 25: ...Español 25 User Manual 12 GUARANTEE CERTIFICATE ...
Страница 27: ...Español 27 User Manual NOTES ...
Страница 28: ...MUDENVER 2016 MU ...