background image

9

FILTER FUNCTION DESCRIPTION & RECOMMENDED 

FILTER REPLACEMENT:

STAGE

FILTER

FUNCTION

REPLACEMENT 

INTERVAL

FT-82

 PP 5μ

Traps dirt, rust, and other impurities.

3~6 months

FT-83 

(G.A.C.) 

Carbon

Removes chemicals and odors, such 

as chlorine and chemical fertilizer. 

Set before the RO membrane can 

protect it from being damaged.

3~6 months

FT-82

 PP 1μ

Fine traps dirt, rust, and other 

impurities.

3~6 months

FT-92 

Carbon 

Block

Removes fine particles and harmful 

pollutants. 

Set before the RO membrane can 

protect it from being damaged.

3~6 months

RO Membrane

This high technology, semi permeable 

membrane effectively takes out TDS, 

viruses, bacteria, slime, heavy metal, 

pesticides, and chemicals etc. Harmful 

impurities separated by the RO 

membrane are diverted to the drain.

1~3 years

FT-86 

Post 

(G.A.C.)Carbon

Drinking water enters this filter after 

the storage tank and is used as final 

polishing filter before the faucet.

It removes objectionable tastes and 

odors. 

12 months

FT-87 

Post 

Remineralizing

Drinking water enters this filter after 

the storage tank.  Remineralize 

drinking water and raises its pH level.

12 months

FT-88 

Post 

Silver Carbon

Drinking water enters this filter after 

the storage tank and is used as final 

polishing filter before the faucet.

Silver ion adds good antibacterial 

property and high safety.

12 months

Note:

Water analysis by qualified  dealer is required to determine optimal lifespan.  
Frequent use or bad quality feed water shortens filter lifespan. If water pressure 

and water quality are not within limits, please contact your distributor to make 

proper modifications.

1

2
3

3

5

4

Содержание CT8

Страница 1: ...RO DRINKING SYSTEM CT8 USER MANUAL Standard 5 Stage Version ...

Страница 2: ......

Страница 3: ... QUICK CONNECTORS WORK 5 7 PRODUCT DESCRIPTION 6 8 FLOW CHART 7 9 ACCESSORIES 8 10 FILTER FUNCTION DESCRIPTION RECOMMENDED FILTER REPLACEMENT 9 11 INSTALLATION DIAGRAM 10 12 INSTALLATION 11 13 HOW TO MOUNT THE WATER PURIFIER ON WALL 14 14 FILTER REPLACEMENT for 1st 2nd 3rd and 5th stage 15 15 RO MEMBRANE REPLACEMENT 17 16 TROUBLESHOOTING 19 ...

Страница 4: ...ality and other relevant technologies to develop series of versatile and economical RO water purifiers and thus able to provide pure and healthy water You will find Puricom CT8 R3 RO system very easy to maintain with its quick simple sanitary filter replacements The good tasty water flows directly a special is also perfect for beverages such as coffee tea and lemonade Please read this manual caref...

Страница 5: ...es of the membrane while the rejected or concentrated is diverted to the drain When the diameter of the pores is less than 0 0001 microns only pure water and a balanced quantity of minerals sodium potassium calcium and magnesium etc can pass through while other substances such as bacteria viruses metals pesticides chemical products etc are eliminated during the process 0 0001μm 5μm 1μm 0 4 1μm 0 0...

Страница 6: ...r product performance may be degraded 5 Do not use with hot water Optimal inlet water temperature is 5 45 6 Inlet water pressure is 15 45 PSI 7 Water analysis TDS should not exceed 1000 PPM Hardness should not exceed 250 PPM 8 Ensure the inlet outlet and drain connections are correct and that the drain point is not blocked 9 The filtration system installation shall comply with state and local laws...

Страница 7: ...nce of filters is degraded 5 Use with Puricom filter products to maintain expected product lifespan and performance 6 After activated carbon filter replacement a certain amount of carbon fines may be introduced to the water It is food grade activated carbon particles and is harmless to the body 7 Before using the filter for the first time or after replacement of the carbon filter run water for a f...

Страница 8: ...pm Temperature 5 45 HOW QUICK CONNECTORS WORK 2 1 Collet Do not remove Insert tubing Push collet in and pull tube out 1 2 safety clip 1 Remove the safety clip from under the collet push in the collet and pull the tube out 2 Ensure the tube is clean and free of burrs Push the tube into the connector until it stops At last pull tube out a little bit and replace the safety clip To disconnect To conne...

Страница 9: ...DUCT DESCRIPTION A 1 C B 4 2 3 5 A Lighten Bracket 1 1st Stage Pre filter B Shut off Valve 2 2nd Stage Pre filter C Q PACK Storage Tank 3 3rd Stage Pre filter 4 4th Stage RO Membrane 5 5th Stage Post Filter ...

Страница 10: ...7 FLOW CHART OUT IN 1 2 3 TANK Drain Shut off Valve RO Feed Water In To Faucet 5 4 ...

Страница 11: ...E Faucet F PVC plug and screws Filters for optional G 1st Stage PP 5μ filter H 2nd Stage Carbon filter I 3rd Stage Carbon CTO PP 1μ filter J 4th Stage RO membrane K 5th Stage Carbon Remineralizing Silver Carbon A B C D E F G H F T 8 2 F T 8 3 I 1 F T 8 3 I 1 F T 8 4 I 1 F T 9 2 K 1 F T 8 6 K 2 F T 8 7 K 3 F T 8 8 J ...

Страница 12: ...ties separated by the RO membrane are diverted to the drain 1 3 years FT 86 Post G A C Carbon Drinking water enters this filter after the storage tank and is used as final polishing filter before the faucet It removes objectionable tastes and odors 12 months FT 87 Post Remineralizing Drinking water enters this filter after the storage tank Remineralize drinking water and raises its pH level 12 mon...

Страница 13: ...10 INSTALLATION DIAGRAM B D A A D C B B C C Feed Water Drain Pressure Tank Pure Water ...

Страница 14: ...veral turns of seal tape on the new feed water connector and install it with the black washer on the existing cold water supply valve 3 Reinstall the existing cold water line on the new feed water connector Wrap several turns of seal tape on the ball valve and install it on the new feed water connector 4 Refer to p 10 Connect the PE tube and complete the feed water assembly ...

Страница 15: ...mp evenly on both sides 3 Refer to p 10 Connect the PE tube and complete the drain clamp assembly C Storage Tank Assembly 1 2 1 Connect the PE tube to the quick connector 2 Refer to p 10 Connect the other end of the PE tube to the filter unit s to tank outlet How quick connectors work can refer to p 5 ...

Страница 16: ...nto the end of the tube 4 Put the end of the tube into the bottom of the faucet and tighten the nut to complete the faucet assembly Refer to p 10 1 Drill a 12mm hole on the right or left hand side of the sink 2 Install the new faucet in the sink hole and from below the sink assemble the mounting hardware 3 Slide the nut from the bottom of the faucet onto the end of the tube Then place the seal on ...

Страница 17: ...C plugs into the wall 3 Use a screwdriver to screw the screws into the PVC plugs The depth of screw protrusion must be uniform 10mm to avoid damage to unit body 4 Aim at the hole of the bracket 5 Hang up the purifier and finish 6 Or it can be placed on the counter leaning against the wall ...

Страница 18: ...hten Tighten 1 Turn off feed water at the feed water valve 2 Turn off the storage tank ball valve 3 Turn on the faucet to release pressure from the tubing 4 Follow the arrow direction to unscrew the old filter 5 Replace the filter 6 Follow the arrow direction to screw the new filter ...

Страница 19: ...16 7 8 9 7 Turn on feed water at the feed water valve 8 Turn on the storage tank ball valve 9 Allow a tank of water to rinse through the system before use ...

Страница 20: ...urn off the storage tank ball valve 3 Turn on the faucet to release pressure from the tubing 4 Pull the disposable RO filter from the bracket 5 Remove the elbow connector out the top and bottom of the RO cartridge 6 Remove the protection caps from the top and bottom of the new RO cartridge ...

Страница 21: ... 7 Connect all the fittings 8 Put the RO cartridge into the bracket 9 Turn on feed water at the feed water valve 10 Turn on the storage tank ball valve 11 Allow a tank of water to rinse through the system before use ...

Страница 22: ...r to extend the lifespan of the RO membrane No permeate or drain water is produced Shut off valve is worn Replace shut off valve TDS value of permeated water is rising rejection rate is lower than 90 1 The ratio of permeate water to drain water is less than 1 3 1 Flow restrictor is clogged Clean it or replace it 2 RO membrane is worn 2 Replace RO membrane Output of permeate water decreases RO memb...

Страница 23: ...20 DEMO ...

Страница 24: ...2015 12 D010123001 ...

Отзывы: