User Manual
PT-C-HDCEC
17
Command
Function
Feedback Example
IRSEND[X].
Send the learned IR command.
X
Description
0
SEND IR DISPLAY OFF
1
SEND IR DISPLAY ON
2
SEND IR USER
IRSEND0.
SEND IR DISPLAY OFF!
IRDLY:[XXX].
Set the sending interval time between IR
ON and IR USER to XXX (default 3s, range
of 1S to 180s).
SET IR ON DELAY TIME [XXX]S
IRPCS[X].
Set the sending number of IR OFF to X.
X
Description
0
1 time
1
2 times
SET SEND IR OFF ONE TIME!
IROFFDLY:[XX].
Set the two times sending interval time
of IR OFF to XX (default 2s, range of 1S
to 10s).
SET IR OFF SEND DELAY TIME
[XXX]S
GIRDLY.
Report the sending interval time
between IR ON and IR USER.
SET IR ON DELAY TIME 3S
GIRPCS.
Report the sending number of IR OFF.
SELECT SEND IR OFF ONE TIME!
GIROFFINT.
Report the two times sending interval
time of IR OFF.
SET IR OFF SEND DELAY TIME 2S
6.1.6
Relay Control Setting
Command
Function
Feedback Example
RELAY1DLY:[XXX].
Set the Relay 1 delay time to XXX
(default 10s, range of 3S to 180s).
SET RELAY 1 TIME DELAY TIME
[XXX]S
RELAY2DLY:[XXX].
Set the Relay 2 delay time to XXX
(default 10s, range of 3S to 180s).
SET RELAY 2 TIME DELAY TIME
[XXX]S
GRELAY1COT.
Report Relay 1 delay time.
SET RELAY 1 TIME DELAY TIME 10S
GRELAY2COT.
Report Relay 2 delay time.
SET RELAY 2 TIME DELAY TIME 10S