Quick Twist Undersink Water Filter System with LED Faucet

Performance Data

Performance Data

Substance

Guidelines*

Average 

Influent 

Concentration

Max Effluent 

Concentration

Min Percent 

Removal

Average 

Effluent 

Concentration

Average 
Percent 

Removal

NSF Standard 42 Drinking Water Treatment Units 

Chlorine 

(11,355 L)

5 - Health                  
0.6 - Aesthetic

2.1

0.3

50%

0.25

>94%

Standard 53 Cyst Live Cryptosporidium POU/POE

Cyst 

<1

100,000

ND (1)

99.98% +

ND (1)

99.99%

Test Parameters

Hardness, Total mg/L

120

TDS mg/L

290

Temp deg C

21°C

Turbidity NTU

0.1

pH

7.57

*Australian Drinking Water Guidelines - 1996

ND = Not Detected

This appliance meets the domestic water treatment appliance Standards AS/NZS3497 for the following 
water treatment processes:

Class

Treatment type

Function

Pass

I

Microbiological Status

Will stop bacteria increasing, but will not 
remove them unless II(a) is passed

N/A

Bacteriostatic

II

Microbiological Treatment

II (a)

Bacteria Removal

Will remove or inactivate bacteria

N/A

II (b)

Virus Removal

Will remove or inactivate virus

N/A

II (c)

Protozoa Removal

Will remove or inactivate Cryptosporidium 
and Giardia, but will not remove or 

inactivate bacteria and virises unless II(a) 
and II(b) is passed

YES

III

Turbidity & Particulate Reduction

Reduces cloudiness

YES

IV

Taste & Odour Reduction

Reduces taste & odours

YES

V

Chemical Treatment

Decreases chlorine

YES

Содержание QT12

Страница 1: ...S 3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System QT12 For correct operation installation it is essential to observe these instructions JUL2018 ...

Страница 2: ...before or after the system Operation The Puretec QT12 system is designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems for 10 minutes after any period of non use more than 2 days For a period of non use of 2 weeks or more it may be necessary to replace cartridge Cartridge Replacement To maintain the high quality of the...

Страница 3: ...r line and connect the Smart Tee Reinstall the previous connection to the tee valve 3 Connect the pressure limiting multivalve to the Smart Tee with a length of white tubing 4 Choose the best position for the faucet taking into consideration height of jugs etc and also the drainage of any spills Then drill a 012 5mm hole and install the faucet as in step 5 5 To install faucet place the escutcheon ...

Страница 4: ... if any before leaving the unit After installing cartridges flush unit for 5 10 minutes Use Guidelines Minimum operating pressure 100 kPa Maximum operating pressure 875 kPa Do not allow exposure to temperatures below 3 C Maximum operating temperature 38 C Maximum flow rate 5 Lpm This system must be installed according to local plumbing codes on the cold water line mains only Replacement Cartridges...

Страница 5: ...out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure 1 12 6 7 8 10 9 11 3 4 5 2 2 2 No DESCRIPTION 1 Smart Tee M x F x T 2 flexible tubing 3 pressure limiting valve 4 QT12R filter cartridge 5 mounting bracket 6 tube nut and olive 7 tube insert 8 faucet lock nut and washer 9 black plastic...

Страница 6: ...black battery seat from the faucet lever handle see figure 2 2 Install battery into the battery seat positive side up Note red light flashes twice and then followed by the blue light 3 Reinstall battery seat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 min...

Страница 7: ...es 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Will stop bacteria increasing but will not remove them unless II a is passed N A Bacteriostatic II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A II b ...

Страница 8: ... no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the Warranties need to be approved by Puretec to ensure product was not incorrectly used installed or claimed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incu...

Отзывы: